502300
1
Verklein
Vergroot
Pagina terug
1/41
Pagina verder
© C. & E. FEIN GmbH. Printed in Germany. Abbildungen unverbindlich. Technische Änderungen vorbehalten. 3 41 01 116 06 0 BY 2010.12 DE.
FEIN Service
USA
FEIN Power Tools Inc.
1030 Alcon Street
Pittsburgh, PA 15220
Telephone: (412) 922-8886
Toll Free: 1-800-441-9878
www.feinus.com
Canada
FEIN Canadian Power Tool
Company
323 Traders Boulevard East
Mississauga, Ontario L4Z 2E5
Telephone.:(905) 8901390
Toll Free: 1-800-265-2581
FEIN Canadian Power Tool
Company
2810 De Miniac
St. Laurent, Quebec H4S 1K9
Telephone: (514) 331-7390
Toll Free: 1-800-789-8181
www.fein.com
Headquarter
C. & E. FEIN GmbH
Hans-Fein-Straße 81
D-73529 Schwäbisch Gmünd-Bargau
www.fein.com
Turbo I
9 20 24
Turbo II
9 20 25
Turbo III
9 20 26
3 41 01 116 06 0 - Umschlag.fm Seite 1 Freitag, 17. Dezember 2010 12:36 12
2
English _____________ Instruction manual_________________
Français ____________ Mode d'emploi____________________
Español _____________ Instrucciones de uso _______________
3
16
29
3 41 01 116 06 0.book Seite 2 Freitag, 17. Dezember 2010 12:42 12
3
en
For your safety.
Read all safety warnings and
all instructions.
Failure to fol-
low the warnings and instructions may result
in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Do not use this vacuum cleaner before
you have thoroughly read and completely
understood this instruction manual. The docu-
ments mentioned should be kept for later use
and enclosed with the vacuum cleaner, should
it be passed on or sold.
Only carry out such operations with this vac-
uum cleaner as intended for by FEIN. Only
use application tools and accessories that have
been released by FEIN.
Please also observe the relevant national
industrial safety regulations.
Non-observance of the safety instructions in
the said documentation can lead to an electric
shock, burns and/or severe injuries.
This Instruction Manual should be kept for
later use and enclosed with the power tool,
should it be passed on or sold.
SAVE THESE INSTRUCTIONS.
Special safety instructions.
Operate the vacuum cleaner only from socket
outlets that are grounded. Only use undamaged
power supply cords and regularly checked
extension cords with grounded contact.
A pro-
tective conductor without continuity can lead
to electric shock.
Operate the vacuum cleaner only off power
supplies whose voltage and frequency values
correspond with the values on the type plate of
the vacuum cleaner.
When wet vacuuming, operate the vacuum
cleaner only when the container is level.
Oth-
erwise there is danger of electric shock from
water penetrating into the vacuum cleaner
motor.
Do not misuse the power supply cord to pull the
vacuum cleaner around or pull the plug from
the socket outlet. Keep the power supply cord
away from heat, oil, sharp edges, or rotating
parts. Do not drive over or pinch the power sup-
ply cord.
Damaged or entangled power supply
cords increase the risk of an electric shock.
Before replacing accessories, pull the plug
from the socket outlet.
This safety measure
reduces the risk of electric shock.
Do not vacuum materials that are hazardous to
one’s health, e. g., dust from beech or oak
wood, masonry dust, asbestos.
These materials
are considered carcinogenic.
Do not vacuum inflammable or explosive fluids;
for example, gasoline, oil, alcohol, solvents. Do
not vacuum hot or inflammable dusts. Do not
operate the machine in rooms where the dan-
ger of an explosion exists.
The dusts, vapors or
fluids can ignite or explode.
This appliance is not intended for used by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or instruc-
tion concerning use of the appliance by a per-
son responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
Do not rivet or screw any name-plates or signs
to the vacuum cleaner.
If the insulation is dam-
aged, protection against an electric shock will
be ineffective. Adhesive labels are recom-
mended.
Do not use accessories not specifically
intended and recommended for this vacuum
cleaner by FEIN.
Just because the accessory can
be attached to your vacuum cleaner, it does
not assure safe operation.
WARNING
3 41 01 116 06 0.book Seite 3 Freitag, 17. Dezember 2010 12:42 12
4
en
Before putting into operation, check the con-
nection and the plug for damage.
Please also observe the operating instructions
and safety warnings of the power tool being
connected to the socket outlet of the vacuum
cleaner.
Extension cord
If the use of an extension cord
is required, its length and con-
ductor cross-section must be adequate for the
applicational case, in order to prevent a volt-
age drop in the extension cord, power loss and
overheating of the power tool.
Otherwise, the
extension cord and power tool are liable to
electrical danger, and the working efficiency is
impaired.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-phase
a. c.:
Vakuumcleaner without power tool
Vakuumcleaner with power tool
Intended use of the vacuum cleaner.
Wet/dry vacuum cleaner for vacuuming and
extraction of dry, non-hazardous dusts,
minor dust particles, particularly when carry-
ing out dust-forming work with a power tool,
and non-combustible liquids, in weather-pro-
tected environments using the application
tools and accessories recommended by FEIN.
WARNING
Min. conductor size
(A.W.G.)
Conductor Size in
mm
2
16 14 12 1.5 2.5 4
Cord Length in Feet Cord Length in Meters
100 100
200
200
300
30 30
60
60
100
Power con-
sumption
Min. conductor size
(A.W.G.)
Conductor Size in
mm
2
1013 16 14 12 1.5 2.5 4
1318 1412– 2.54
Cord Length in Feet Cord Length in Meters
100 100
200
200
300
30 30
60
60
100
3 41 01 116 06 0.book Seite 4 Freitag, 17. Dezember 2010 12:42 12
5
en
Symbols.
Symbol Explanation
Action to be taken by the user
General prohibition sign. This action is forbidden!
Observe the instructions in the text or graphic opposite!
Be absolutely sure to read the enclosed documentation such as the
Instruction Manual and the General Safety Instructions.
Before commencing this working step, pull the plug out of the socket.
Otherwise there may be danger of injury caused by unintentional start-
ing of the vacuum cleaner.
This symbol confirms the certification of this product for the USA and
Canada.
This sign warns of a directly imminent, dangerous situation. A false reac-
tion can cause a severe or fatal injury.
This sign indicates a possible dangerous situation that could cause severe
or fatal injury.
This sign warns of a possible dangerous situation that could cause injury.
Worn out power tools and other electrotechnical and electrical prod-
ucts should be sorted separately for environment-friendly recycling.
Product with basic insulation and exposed (touchable), conductive parts
additionally connected to the protective earth conductor.
~ or a. c. Alternating current
1 ~ Alternating current single-phase
Ø
Diameter of a round part
DANGER
WARNING
CAUTION
Unit of measure, national Explanation
W Unit of measure for electrical power
l Unit of measure for volume
l/min Unit of measure for air flow (air volume)
mbar Unit of measure for pressure
m, s, kg, A, mm, V, W, Hz, N,
°C, dB, min, m/s
2
Basic and derived units of measure from the international sys-
tem of units
SI
.
3 41 01 116 06 0.book Seite 5 Freitag, 17. Dezember 2010 12:42 12
6
en
Technical description and specifications.
Before mounting or replacing accessories, pull the plug.
This preventive safety
measure rules out the danger of injuries through accidental starting of the vac-
uum cleaner.
Your vacuum cleaner may include only a part of the accessories described or shown in this
instruction manual.
Type Turbo I Turbo II Turbo III
Reference number 9 20 24 9 20 25 9 20 26
Power input 1000 W 1050 W 1200 W
Max. connected load of the integrated socket
outlet 1800 W 1800 W 1800 W
Power supply type 1 ~ 1 ~ 1 ~
Container volume 24 l 35 l 55 l
Air flow 3200 l/min 3200 l/min 3500 l/min
Max. pressure difference 230 mbar 230 mbar 250 mbar
Weight according to
EPTA-Procedure 01/2003 9.8 kg 10.5 kg 11.6 kg
Class of protection I I I
WARNING
Fig. 1
Hose connection
socket
Air-flow regulator
Casters
On/Off switch
Integrated socket
outlet
Handle
Cord holder
Fastener
3 41 01 116 06 0.book Seite 6 Freitag, 17. Dezember 2010 12:42 12
7
en
Removing accessories (
Figure
2).
Upon delivery, all accessories are inside the
vacuum cleaner.
Open the fasteners on both sides and
take off the vacuum cleaner lid.
Remove the accessories from inside
the vacuum cleaner (the figure aside is
symbolic).
Assembly instructions.
Before mounting or replacing accessories, pull the plug.
This preventive safety
measure rules out the danger of injuries through accidental starting of the vac-
uum cleaner.
Use the textile permanent filter only for dry vacuuming.
Emptying the vacuum cleaner
(Figure 3).
Open the fasteners on both sides and
take off the vacuum cleaner lid.
Remove the textile permanent filter
upward and clean it, if heavily soiled or
when the vacuuming performance
decreases.
Empty the contents of the vacuum
cleaner base into a waste or trash can.
The 5 micron textile permanent
filter is only suitable for non-
hazardous dusts.
2.
3.
4.
1.
Fig. 2
Vacuum
cleaner
lid
Fas-
tener
WARNING
WARNING
Fig. 3
Textile
permanent
filter
3 41 01 116 06 0.book Seite 7 Freitag, 17. Dezember 2010 12:42 12
8
en
Inserting a paper-dust bag (Figure 4).
Use the paper-dust bag in conjunction
with the filter cartridge only for dry vac-
uuming.
When inserting a paper-dust bag, take care
that the cardboard flange and the paper-dust
bag face completely against the inside wall of
the container.
Open the fasteners on both sides and
take off the vacuum cleaner lid.
Grasp the new paper-dust bag by the
cardboard flange, first at the bottom then
at the top, and slide it over the cog.
Mount the vacuum cleaner lid again
and close the fasteners.
The paper-dust bag is removed in reverse
order.
After removing the paper-dust bag, seal it
with the closing cover in order to avoid
debris.
Changing the filter cartridge (Figure 5).
Use the filter cartridge with or without
additional paper-dust bag only for dry
vacuuming!
Keep the filter cartridge dry and clean it regu-
larly.
Replace the filter cartridge when the vacuum
performance decreases.
Open the fasteners on both sides and
take off the vacuum cleaner lid.
Screw the nut at the bottom side of
the filter cartridge counterclockwise and
remove the filter cartridge.
Mount the new filter cartridge cen-
tered and screw the nut clockwise to the
stop.
Mount the vacuum cleaner lid again
and close the fasteners.
Fig. 4
Paper-
dust bag
1.
2.
Fig. 5
Filter cartridge
Nut
3 41 01 116 06 0.book Seite 8 Freitag, 17. Dezember 2010 12:42 12
9
en
Mounting/dismounting the vacuum
hose (Figure 6).
Turbo I, Turbo II:
Insert the vacuum hose to the stop in
the hose connection socket until tightly
seated.
To remove the vacuum hose, press the
release button and pull the vacuum hose
out.
Turbo III:
Insert the vacuum hose into the hose
connection socket until tightly seated.
To remove the vacuum hose, hold
hose close to the vacuum body and twist
hose while pulling.
Mount accessories applying only slight
pressure. For disassembling, turn the
parts somewhat against each other and
pull apart.
Working instructions.
Before mounting or replacing accessories, pull the plug.
This preventive safety
measure rules out the danger of injuries through accidental starting of the vac-
uum cleaner.
The motor of the vacuum cleaner is equipped
with a soft-start function.
The vacuum cleaner starts with the last set
suction capacity.
Switching on and off without a power
tool connected (Figure 7).
First check that the power
cord and power plug are not
damaged.
Switching ON
:
Set the On/Off switch to (
II
).
Switching OFF
:
Set the On/Off switch to (
O
).
Fig. 6
Hose
connection
socket
Vacuum hose
WARNING
WARNING
Fig. 7
On/Off switch
3 41 01 116 06 0.book Seite 9 Freitag, 17. Dezember 2010 12:42 12
10
en
Switching on and off with a power tool
connected (Figure 8).
Switch the vacuum cleaner off before con-
necting a power tool to the integrated vac-
uum cleaner socket outlet. Make sure that the
power tool is switched off when inserting its
plug into the vacuum cleaner socket outlet.
The vacuum cleaner is automatically switched
on and off via the power tool connected to
the integrated socket outlet.
Plug the plug of the power tool into
the integrated socket outlet.
Set the On/Off switch to (
I
).
Switch the power tool on/off – the
vacuum cleaner automatically starts/
stops.
After switching off a power tool con-
nected to the vacuum cleaner socket
outlet, the vacuum cleaner will run on
for approx. 5 seconds and then automat-
ically switch off.
Regulating the air flow (Figure 9).
The air flow can be increased or decreased
over 5 levels.
To increase the air flow, press the air-
volume regulator to (+).
To decrease the air flow, press the air-
volume regulator to (–).
1.
2.
3.
Fig. 8
Integrated socket outlet
On/Off switch
Fig. 9
Air-flow
regulator
3 41 01 116 06 0.book Seite 10 Freitag, 17. Dezember 2010 12:42 12
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Fein Turbo 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Fein Turbo 3 in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 2,4 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.