5.B - STANDARDIZED PROGRAMS
5.A - YOUR DRYER’S PROGRAMS
RECOMMENDED PROGRAMS FOR TESTS TO EN 61121 - DIRECTIVE 95/13/EEC
Programs Type of textile Drying results
COTTON
Extra drying
Cotton Dry
Dry
Cotton Dry
Ready to iron
Cotton Slightly damp
Machine pressing
Cotton Damp
MIXED
Dry
Regular textiles Dry
Ready to iron
Regular textiles Slightly damp
Other drying programs
Schirts
Synthetic, easy iron Dry
Synthetics
Delicate, synthetic Dry
Delicates
Very delicate: silk, light
synthetic lingerie ...
Dry
Refreshing and airing your textiles after prolonged storage
Air and refresh
Other textiles 15 minutes
Air woollens
Woollens 6 minutes
Load I ”Dry cotton” 8 kg .... select “Cotton” - Dry
Load II ”Ready to iron cottonr” 8 kg .... select “Cotton” - Ready to iron
Load III ”Easy care textiles” 4 kg .... select “Synthetics”
4.1 - CLEANING THE FILTER
This is located in the lower part of your dryer.
Clean it as follows:
— Remove it from its housing by pulling it upwards
(Fig. 4.1.1).
— Open the filter and clean it by removing the thin
coating of fluff covering it
(Fig. 4.1.2).
— Re-insert it in its housing, pushing it well in.
Do not wash filter with water (Fig. 4.1.3).
The filter must be cleaned after every drying.
4.2 - EMPTYING THE CONDENSATE CONTAINER
This is located at the top or bottom of your
appliance (according to model), and it recovers the
water extracted from your items during drying.
— To empty it, release it from its housing by pulling it
towards you
(Fig. 4.2.1).
The condensate container must be emptied
after each drying cycle (Fig. 4.2.2).
— Empty the condensate container if there is a risk
of frost, or if you wish to move or tilt your
appliance.
4.3 - CLEANING THE CONDENSER
The condenser must be cleaned twice a
month.
— Unplug the power cable from the socket before
cleaning the condenser.
Clean it as follows:
— Open the grill at the front of the appliance.
— Release the condenser and remove it carefully
(Fig. 4.3.1).
— Remove any fluff from the condenser. Clean it with
water only under the tap
(Fig. 4.3.2).
— After cleaning, ensure that none of the tubes are
“blocked” and that the fins are clean.
— Rub it superficially.
— Re-insert the condenser and lock it in place. Close
the grill.
When refitting the condenser, ensure that it
is pushed in firmly right to the back of its
housing when locking it in.
4 - REGULAR MAINTENANCE
4.4 - CLEANING THE APPLIANCE
To clean the control panel, the access to the drum
and the casing, use only a sponge or a damp cloth
and some soapy water.
— Ensure that there is no fluff accumulating round
the dryer.
— Clean the door seal with a damp cloth and the fil-
ter housing with your vacuum cleaner once a year.
— You should not use, under any circumstances,
the abrasive powders, the metal or plastic spon-
ges and the alcohol-based products (Fig. 4.4).
4.5 - DIRECT EVACUATION OF WATER CONDEN-
SER
(Top condensate container models only)
To avoid having to empty the collection tank every
time you use the appliance, you have a kit (*) for
removing the water from the condenser directly into
the drain (hose and deflector). To fit this:
— Take off the existing pipe and push it inside
the appliance
(Fig. 4.5.1).
— Clip the deflector with the top of the pump
(Fig. 4.5.1).
— Connect the hose from the kit to the end
CC
BB
AA
connector on the appliancl
(Fig. 4.5.2).
You can connect the other end of the hose either:
- To a ventilated trap
(Fig. 4.5.3).
- Or a sink trap
(Fig. 4.5.4).
When connecting to a trap, you must remove the fil-
ler plug. Then press home the rubber tip. If neces-
sary, add a clamp connection
(Fig. 5.4).
— (*) This kit is provided with the appliance or is
available near your After-sales service (according
to model).
— The deflector must necessarily be positioned
before the drain hose connection.
4.6 - CHANGING THE BULB
(according to model)
You can replace the light bulb (type E14-15W/230V)
yourself
(Fig. 1.1)
. To do this:
— Unscrew the glass cover located to the left inside
the appliance.
— Unscrew the extinguished bulb and replace it
.
—
Screw on the glass cover tightly.
Important:
Unplug the power cord before
changing the bulb. The bulb must be repla-
ced when the appliance is cooled down.
GG