CONNECTING
AND
MOUNTING
THE SENSOR
1. FLUSH-MOUNTING
MOUNTING ON PANELS OR IN A WALL WITH A RECESSED HOUSING
• Bore a hole with a hole saw,
according to the diameter of the
recessed housing
• Place the recessed housing
and pass the cable in such way
that the Magic Switch’s fastening
screws are located horizontally
• Unscrew the Magic Switch
fastening screws on the housing
• Remove the front side of the
Magic Switch
• Connect the Magic Switch
• Adjust the sensor (see sensor settings)
• Fasten the Magic Switch to the
housing using the Magic Switch’s
fastening screws
• Fasten the housing on the panel
• Put back the front side
• Place the sticker
REMARK :
To make the sensor insensitive to
any type of infiltration, you can
place a silicone seal when closing
the sensor
Panel fastening
screws
Back side
Magic Switch fastening screws
INSTALLATION
TIPS
• Do not place objects that could
move in front of the sensor
• Do not place the sensor in the
door’s opening range