08. ELECTRONICS WITH N.100 3 BUTTON LED DISPLAY
08.1 CONSOLE
Console
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available according to the access
level can be modified by entering the menu. A display and the LED indicators inform about the stove operational status.
Depending on the operating mode, the displays may take on different meanings depending on their position on the display.
PANEL DESCRIPTION
LED (L0) set room Button (P1) decrease/menu/set room temperature
LED (L1) set heat output Button (P2) increase/stove status/set heat output
LED (L2) chrono Button (P3) ON/OFF/ esc/confirm
LED (L3) ON/OFF
LED (L4) alarm Display (D1) status/heat output/parameter
LED (L5) auger/exchanger/glow plug
08.2 MENU
MENU
Hold P1 button down to access the menu.
It includes several items and levels to access settings and control board programming.
Menu M1 SET CLOCK
Keep button (P1) pressed until message M1 appears, confirm with the ON/OFF button (P3), with buttons (P1) and (P2), change the current day and press the
ignition button; set the hour and press ON/OFF (P3); set the minutes and press ON/OFF (P3); set the current day as a number and press ON/OFF (P3), set the
current month and press ON/OFF (P3), set the current year; to confirm and exit keep the ON/OFF (P3) button pressed until the time reappears.
Menu M2 SET CHRONO
Sub-menu M2 1 CHRONO ENABLE
Keep button (P1) pressed until message M1 appears, press the (P2) button up to M2, confirm with ON/OFF button (P3); the menu M2-1 appears, confirm with
ON/OFF (P3) and with the arrow (P1) set ON to activate the general chrono; go back keeping ON/OFF (P3) pressed, with button (P2) choose the programme
to enable.
Sub-menu M2 2 PROGRAM DAY
Two fixed ON/OFF cycles for each day.
Sub-menu M2 3 PROGRAM UEEK
The weekly programmable chrono-thermostat functions can be enabled, disabled and set. The weekly programmer has 4 independent programs whose final
effect involves the combination of the 4 individual programs. The weekly programmer can be enabled or disabled. Moreover, if the time is set to OFF, the clock
ignores the corresponding control.
Caution: set carefully to prevent overlapping of different activation times of different programmes on the same day.
Sub-menu M2 4 PROGRAM U-END
The programmable chrono-thermostat functions can be enabled, disabled and set for the week-end (days 5 and 6, or Saturday and Sunday)
SUGGESTION: if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted stove
switching on and off.
Disable the daily programme if you want to use the weekly programme. If you use the weekly programme for 1, 2, 3 and 4 programmes, never enable the week-
end programme.
Always disable the weekly programme before enabling the week-end programme.
Setting a programme
Enter the desired programme by pressing ON/OFF (P3) once. The first parameter is the enabling of the programme itself, which should be set to ON by pressing
the (P2) button (CAUTION: ENABLE ONE PROGRAMME AT A TIME TO PREVENT ISSUES WITH THE CHRONO). Press ON/OFF (P3), to set the START time,
with buttons (P1) and (P2) enter the desired switch-on time; press SET (P3) to set the STOP time: with arrows (P1) and (P2) set the switch-off time; only for the
weekly program, press SET (P3) with the days requiring confirmation, with the ON/OFF button, navigate between the days of the week and with buttons (P1) and
(P2), set ON or OFF. Once the times and days have been set, to confirm and exit the chrono, press and hold the ON/OFF button until the initial screen is seen; if
the times have been set correctly, a green LED will illuminate near the clock at the top left of the display.
Menu M3 LANGUAGE
Use this command to select one of the languages available. Press P2 (increase) and P1 (decrease) buttons to scroll through the options and press P3 button to
confirm.
Menu M4 STAND-BY
Use to enable or disable Stand-by mode. Press P3 button to select menu M4 and then P1 (decrease) or P2 (increase) button to select the ON or OFF status.
Menu M5 BUZZER
Allows the controller buzzer to be enabled or disabled during alarm signalling. Press the P1 or P2 button to enable or disable this command and P3 to confirm.
L2
L4
L5
L3
P3
P2
L1
P1
L0
D1
16
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor TEK 80 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor TEK 80 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.55 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor TEK 80

Eva Calor TEK 80 Gebruiksaanwijzing - Deutsch - 28 pagina's

Eva Calor TEK 80 Gebruiksaanwijzing - Français - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info