04. MINIMUM INSTALLATION REQUIREMENTS
INTRODUCTION:
INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL
REGULATIONS.
Eva Stampaggi S.r.l. assumes no responsibility for injury to persons and/or damage to property caused by the non-observance of the point
highlighted above for non-compliant installed products.
Install the stove according to the regulations in force in the country of use.
In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas:
a. preliminary activities - are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary
procedures include:
installation site suitability verification;
fume evacuation system suitability verification;
external air inlet suitability verification.
At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met.
Safety conditions must be assessed with a preventive inspection.
Stoves and fireplaces are heating systems and must be installed safely and comply with the manufacturer's instructions!
b. installation - under the responsibility of the installer. In this phase the installation of the product and the smoke exhaustion system are considered as well as
the handling of topics such as:
safety distance from combustible materials;
chimney flue construction, smoke ducts, intubated systems and chimney cowls.
c. issuance of supplementary documentation - the responsibility of the installer.
The release of technical documentation must include:
manual of use and maintenance of the appliance and of the components of the system (e.g. smoke ducts, chimney flue, etc.);
Photocopy or photograph of the chimney flue plate;
system manual: (if applicable);
Declaration of Conformity in relation to Ministerial Decree 37/08.
d. control and maintenance - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation
over time. The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in a workmanlike manner
and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with
the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who
signs a copy thereby confirming receipt and reading thereof.
In addition to what is specifically provided for in the following paragraphs of this Instruction Manual, the Purchaser must comply with the following minimum
installation requirements:
a) Do not invert or place the stove horizontally on one side;
b) The heat output of the stove must be adapted to the size of the room where it is to be installed and the room must be ventilated from the outside;
c) The assembly of the flue pipe must be carried out in a workmanlike manner and according to European (UNI 10683) and national regulations, local
regulations and the technical specifications and warnings contained in this Instruction Manual;
d) The smoke outlet must be connected to the flue pipe by means of telescopic fittings;
e) The diameter of the flue must be less than 150 mm.
f) The connection to the flue pipe must be made with an inclination connection of less than 45°;
g) The flue pipe must be suitably insulated;
h) The minimum length of the horizontal section must be greater than 2 metres;
i) The minimum slope of the horizontal section must be 5%;
j) The chimney and/or flue pipe must be waterproofed;
k) The flue shall not have more than two changes of direction;
l) The flue gas must be discharged directly into the flue pipe;
m) The flue gas duct must have a length of less than 6.0 m before the flue, with a maximum horizontal section of 3.0 m;
n) The flue and flue duct must not narrow in width from the initial diameter for its entire length. The initial diameter shall be that of the exhaust outlet of the
stove body;
o) The minimum ventilation duct opening must be 80 cm²;
p) The distance of the flammable walls must be respected, as prescribed on the “stove data plate”;
q) The burn pot must be cleaned before each ignition of the stove.
The Buyer must not make any structural changes to the stove and must not make any operating changes to the electrical board.
Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683) and national
regulations, local regulations and assembly instructions contained in this Instruction Manual.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, for damage to persons or property resulting from non-compliance with the
aforementioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual.
Failure to comply with the installation requirements and/or tampering with the stove may result in: inadequate heat output and/or abnormal product behaviour,
poor flue gas draught, clogging of the burn pot, slow combustion, hopper fire, overheating and fire hazard of the stove, fire hazard of the flue gas duct, or lack of
oxygen in the environment where the stove is located.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused
by non-compliance with the requirements for installation of the stove and/or tampering with it.
The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of
such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to
persons or property, resulting from the use of the product.
Caution: in the event of ignition fault or power outage, the burn pot must be emptied before repeating the operation. Failure to follow this procedure
may result in glass breakage.
6
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor SB 80 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor SB 80 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.55 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor SB 80

Eva Calor SB 80 Gebruiksaanwijzing - Deutsch - 28 pagina's

Eva Calor SB 80 Gebruiksaanwijzing - Français - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info