The calorific value depends therefore, on the density of the wood (that varies based on its type) and on its moisture content. The heat output of the stoves is directly
affected by this factors. Depending on its moisture content, it can be indicated in:
% of humidity
Calorific heat output kcal/kg
15%
3490
20%
3250
25%
3010
30%
2780
35%
2450
40%
2300
On average, a well seasoned wood has a calorific value of 3200 kcal/kg.
06. INSTALLATION WARNINGS
06.1 HERMETIC STOVE
The hermetic wood stove body is available for outputs 8 and 12.5 kW. If properly connected by means of a suction tube, these stoves draw the combustion air and
the air necessary for glass cleaning directly from outside and not from the room where they are installed, preserving the oxygen in the room. Using coaxial tubes,
the air will be pre-warmed contributing to improved combustion and lower emissions into the atmosphere. Ideal for passive houses, they offer best comfort at the
lowest cost.
Before installation, the following indications must be respected:
Select the position where the stove is to be installed and:
Choose whether the appliance will have a rear or upper flue gas outlet.
Provide the connection to the flue pipe for the expulsion of the fumes.
Provide the external air intake (combustion air) and check for its presence: it must be drawn from a free space (not spaces where extractor fans exist or
without ventilation) or from outside.
Place the stove on the floor in a position that is advantageous for connection with the flue pipe and near the "combustion air" intake
The appliance must be installed on a floor with an adequate loading-bearing capacity. Should the existing floor not comply with the requirement above, proper
measurements must be taken (for instance, the installation of a load distribution plate).
All the structures which could catch fire if exposed to excessive heat must be protected. Flooring made from wood or inflammable materials must be protected
using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning of the stove, exhaust pipes and flue pipe.
This appliance is not suitable to be installed on a shared flue pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positioned at the same height of the
pipe located on the stove back. When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should not
be other naked flame devices in the same room.
The combustion air intake (Ø 80mm) must be connected directly to the outside or to adjacent rooms provided
they are fitted with external air supply vents (Ø 80mm) and are not used as bedrooms or bathrooms or, whenever
a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. The air vents must be
placed in such a way that they cannot be clogged either from the outside or inside and must be protected using
a grille, a metal mesh or other suitable means provided they do not reduce the minimum section. For the
connection to the external intake, it is necessary to break the pre-cuts in the lower part of the stove back and to
connect the pipes with a dedicated seal to the appropriate intake.
If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood
cladding, etc.), the following minimum clearances must be complied with: "SEE STOVE DATA PLATE”
The 8.5 kW stove does not have a connection to the combustion air intake.
It is however advisable, in addition to respecting the minimum distances, to install heat-resistant flame-retardant
insulating panels (rock wool, aerated concrete, etc.)
The following is recommend:
Promasil 1000
Classification temperature: 1000°C
Density: 245 kg/m³
Shrinkage at reference temperature, 12 h: 1.3/1000°C %
Cold crushing strength: 1.4 MPa
Bending strength: 0.5 MPa
Reversible thermal expansion: 5.4x10-6 m/mK
Specific heat capacity: 1.03 kJ/kg K
Thermal conductivity λ:
200°C 0.07 W/mK
400°C 0.10 W/mK
600°C 0.14 W/mK
800°C 0.17 W/mK
Thickness: 40 mm
07. INSTALLATION
Unpack the stove: be careful not to damage the product at the time of unpacking.
Check the stove's legs and adjust them so that the stove is stable.
Place the stove so that the door and any window openings are not against the walls.
After connecting the stove to the combustion air inlet join the coupling device to the flue pipe.
ATTENTION: the 8 kW and 12.5 kW stoves must be installed with a minimum of 1 meter of Ø 150 pipe, certified according to the
EN1856-2 standard.
The exhaust fume pipes must be suitable for wood-burning stoves and must therefore be made from coated steel or stainless steel,
with a diameter of 150 mm and fitted with adequate seals.
The 8.5 kW stove has a fume outlet diameter of 120 mm. Follow the same directions listed above.
9
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor Margherita bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor Margherita in de taal/talen: Engels als bijlage per email.

De handleiding is 2.3 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor Margherita

Eva Calor Margherita Gebruiksaanwijzing - Deutsch - 16 pagina's

Eva Calor Margherita Gebruiksaanwijzing - Français - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info