668816
4
Verklein
Vergroot
Pagina terug
1/55
Pagina verder
1.4 Connection to the chimney flue ......................................................................................... 7
1.5 Preventing house fires ....................................................................................................... 7
2
SPECIFICATIONS AND TECHNICAL DATA............................................................. 7
2.1 Specifications .................................................................................................................... 7
2.2 Technical data (see attached sheet) .................................................................................. 8
2.3 Rear connection dimensions (see attached sheet) ............................................................ 8
2.4 Product identification data (see attached sheet) ................................................................ 8
2.5 Electrical diagrams ............................................................................................................ 8
2.5.1 Hydro stoves and boilers ................................................................................................... 8
2.5.2 Air /Channelled Air........................................................................................................... 10
3
FUEL ........................................................................................................................ 11
3.1 General notes .................................................................................................................. 11
4
INSTALLATION ........................................................................................................ 12
4.1 General notes .................................................................................................................. 12
4.2 Minimum safety distances ............................................................................................... 12
4.2.1 Corner installation (mm) .................................................................................................. 12
4.2.2 Wall installation (mm) ...................................................................................................... 13
4.2.3 Distance from flammable ceilings and false ceilings (mm) ............................................... 14
4.2.4 Distance of fume exhaust system from flammable walls (mm) ......................................... 14
4.3 Flooring protection ........................................................................................................... 15
4.4 Minimum distances for positioning air intake vents .......................................................... 15
4.5 Fume exhaust duct .......................................................................................................... 16
4.5.1 General notes .................................................................................................................. 16
4.5.2 Tubes and maximum usable lengths ............................................................................... 16
4.5.3 Holes for exhaust tube passage on walls or roof: recommended insulation and diameter 17
4.5.4 Using a traditional type chimney flue ............................................................................... 17
4.6 Using an external fume duct ............................................................................................ 18
5
ASSEMBLY .............................................................................................................. 19
5.1 General notes .................................................................................................................. 19
5.2 Unpacking ....................................................................................................................... 19
5.3 Electrical connection ........................................................................................................ 19
5.4 Water connection (only for hydro and boiler models) ....................................................... 20
5.5 Heating stove hydraulic diagram (only for hydro and boiler models) ................................ 20
5.5.1 Indicative hydraulic diagram heating only (only for hydro and boiler models) ................... 21
5.6 External thermostat installation ........................................................................................ 21
5.7 Remote control ................................................................................................................ 21
6
USE .......................................................................................................................... 22
6.1 Console description ......................................................................................................... 23
6.2 First ignition ..................................................................................................................... 25
6.3 Ignition and normal operation .......................................................................................... 25
6.3.1 Stove start-up .................................................................................................................. 25
6.3.2 No start-up ...................................................................................................................... 26
6.3.3 Normal Operation ............................................................................................................ 27
6.3.4 Modulation based on room temperature (all models) ....................................................... 28
6.3.5 Modulation based on boiler water temperature (Hydro stoves and boilers only) .............. 28
6.3.6 Ventilation (air and channelled air models) ...................................................................... 28
6.3.7 Circulator (hydro and boiler models) ................................................................................ 29
6.3.8 External thermostat ......................................................................................................... 29
6.3.9 Brazier cleaning ............................................................................................................... 29
6.3.10 Shutdown .................................................................................................................. 29
6.3.11 Interruption of power supply ....................................................................................... 30
6.3.12 Remote control. ......................................................................................................... 30
7
MENU ....................................................................................................................... 31
7.1 Menu 01 "WATER PRESSURE" ...................................................................................... 31
Menu 01 "FANS ADJUSTMENT" .............................................................................................. 31
7.2 Menu 02 "CLOCK SET" ................................................................................................... 32
7.3 Menu 03 "CHRONO SET" ............................................................................................... 32
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor Giove bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor Giove in de taal/talen: Engels als bijlage per email.

De handleiding is 5,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor Giove

Eva Calor Giove Gebruiksaanwijzing - Nederlands - 90 pagina's

Eva Calor Giove Gebruiksaanwijzing - Deutsch - 38 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info