9.2.LED indicators
Active Chrono LED (L1):
The LED is on when the UT1 user parameter has a value different from OFF and the weekly or daily programming
can be set.
Auger tube ON LED (L2):
The LED is on whenever the Auger tube is enabled and the motor, feeding the pellets in the combustion chamber, is
working, i.e. during START-UP and WORK mode.
Remote control receiverLED(L3):
The LED flashes whenever the control panel receives a signal from the IR remote control to modify temperature/heat
output.
Room thermostat LED (L4):
The LED is on whenever the room temperature is higher than the set temperature (external thermostat not in use). If
an external thermostat is available, the LED is on whenever the fume temperature exceeds 250°C.
Temperature setting LED (L5):
The LED flashes when working in the user/technician menu or while setting the temperature.
9.3.TheDisplays
Status/Heat Output/Paramenter label Display (D1):
It shows the board status during start-up phase.
During working mode, it shows the heat output set by the user.
When modifying user/technician parameters, it shows the label of the parameter in question.
Status/Time/Temperature/Parameter value Display (D2):
It shows the board status during start-up phase.
During working mode, it shows the temperature set by the user.
When modifying user/technician parameters, it shows the value of the parameter in question.