off. If the power outage takes place when the stove is in ECO STOP mode, the stove will return to this mode regardless of how long the outage period is. In all
other cases, the stove switches off after the power supply is restored. The stove can also enter a safety alarm condition. In this case you need to reset the safety
thermostat placed on the back of the stove.
Insufficient pellet level
The stove is equipped with a sensor that controls the level of pellet. The stove does not start if the pellet level is too low. During the work phase the stove will
operate at minimum heat output.
ALARMS
To each event corresponds an alarm that is activated after the delay time indicated when the event occurs.
If the cause of the alarm is not removed within this period of time, the stove enters the alarm condition, shuts down immediately and enables the fume fan and the
exchanger fan at maximum speed. The devices are then switched off once the fume temperature reaches the lowes set value. Each alarm condition, except for
"no fire" is recorded in the alarm history.
ALARM DESCRIPTION
No fire
the fume temperature does not meet the necessary conditions for ignition
FAIL
the fume temperature does not meet the necessary conditions for stabilisation
Al. SmokeT
the fume temperature reached and exceeded the maximum set threshold
No fire
the fume temperature dropped below the minimum set threshold
Al. Vacuos / Al depr.
the vacuum switch signalled an anomalous pressure/vacuum
Al. Safety
the thermostat detected an excessive temperature (exceeding the relevant threshold)
Al. roomP.
the room sensor is connected, not working properly (short circuit or stopped)
Al. smokeP
the fume thermocouple i connected, not working properly (short circuit or stopped)
Al. blower
the fume fan is blocked or rotates at a speed lower than 300 rpm.
Al. flux
the value detected by the flow sensor indicates a malfunction. The flow control is enabled but the flow rate cannot be adjusted automatically.
T. elect (°C)
the temperature inside the stove and therefore of the electronic board exceeded the maximum threshold of 70° c.
Reset
Press the P2 (ON/OFF) key to silence the alarm, then hold the P2 (ON/OFF) button to switch off the stove.
If the stove does not switch off, contact technical assistance. Avoid disconnecting the stove from the mains if the flame did not disappear completely.
05.8 IR REMOTE CONTROL (optional)
(Pellets stoves - Pellet stove with oven – Pellet kitchen – Pellet kitchen with oven – Pellet inserts)
IR Remote control
The stove control panel is set up to receive certain functions via remote control.
Ignition/shutoff function: pressing the 1 and 6 buttons at the same time turns the stove on or off.
Power regulation: during normal operation, pressing the 5 and 6 buttons, labelled with the flame, lets you set one of
the stove power levels.
Temperature regulation: during normal operation, pressing the 2 button and then the 1 and 2 buttons, labelled with the
thermometer, lets you set the temperature.
06. CLEANING AND MAINTENANCE
INTRODUCTION
The stove requires a simple yet constant cleaning to guarantee top efficiency and proper functioning.
Constant maintenance by a qualified technician is recommended.
The stove should be cleaned before the cold season because it can sometimes get clogged during the summer (by nests for example) preventing exhaust fumes
to flow regularly.
At the beginning of the season and in case of wind, a build-up of residue in the pipe may lead to fires. Should this happen, find below a few pieces of advice to
follow:
Block air supply to the pipe immediately;
Throw sand or kitchen salt, and not water, to extinguish fire and coals;
Keep objects and furniture away from the burning pipe.
ALSO TO PREVENT THIS TYPE OF FAULT YEARLY CLEANING OF THE VENT PIPE IS ESSENTIAL, REMOVING DEPOSITS OR ANY POCKETS OR
OBSTRUCTIONS.
ATTENTION:
USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY
THE AUGER TUBE MUST BE COMPLETELY EMPTIED FROM PELLETS WHEN USING THE STOVE FOR THE LAST TIME AT THE END OF THE
SEASON. THE AUGER TUBE MUST REMAIN EMPTY TO PREVENT IT FROM BECOMING CLOGGED BY SAWDUST RESIDUES THAT HAVE
SOLIDIFIED DUE TO MOISTURE.
DAILY CLEANING
Any cleaning operation must be performed when the stove is completely cold:
Empty the ash drawer: vacuum it out or dispose of the ashes in a waste bin.
Vacuum the combustion chamber: check that there are no embers that may still be lit. In this case your ash vacuum cleaner will
catch fire.
Remove the ash inside firebox and on door.
Wipe the glass with a damp cloth or a damp ball of newspaper dipped into the ash. If the operation is performed with the stove hot
there is a risk of the glass exploding.
ONLY FOR PELLET KITCHEN
It is also possible to raise the plate (or glass) and aspirate the fume circulator.
When the fume circulator is clean ensure the plate is well positioned.
ATTENTION: USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY DO NOT USE ABRASIVE MATERIALS OR PRODUCTS THAT MAY CORRODE
OR LIGHTEN THE SURFACES.
MANUFACTUTER LIABILITY
The manufacturer shall not be held liable against any direct and/or indirect, criminal and/or third party liability arising from:
31
31

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Eva-Calor-Erika

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor Erika bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor Erika in de taal/talen: Engels als bijlage per email.

De handleiding is 5,83 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor Erika

Eva Calor Erika Gebruiksaanwijzing en installatiehandleiding - Nederlands - 90 pagina's

Eva Calor Erika Gebruiksaanwijzing - Deutsch - 38 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info