All the structures which could catch fire if exposed to excessive heat must be protected.
Floors made from wood or inflammable materials must be protected using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
This appliance is not suitable to be installed on a shared vent pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positioned at the same height of the
pipe located on the stove back. Exhaust fume pipes must be suitable for pellet stoves and must therefore be made from coated steel or stainless steel, with a
diameter of 8cm and fitted with adequate gaskets.
The combustion air intake must be connected directly to the outside or to adjacent rooms provided they are fitted with external air supply vents and are not
used as bedrooms or bathrooms or, whenever a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. The air vents must be
placed in such a way that they cannot be clogged either from the outside or inside and must be protected using a grille, a metal mesh or other suitable means
provided they do not reduce the minimum section.
If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood cladding, etc.), the following minimum clearances
must be complied with:
PELLET STOVES and AIR STOVES
COMBUSTABLE NON-FLAMMABLE COMBUSTABLE NON-FLAMMABLE
AIR STOVE 15 KW
AIR STOVE 15 KW
AIR-TIGHT STOVES 8 KW
AIR-TIGHT STOVES 8 KW
REAR WALL P = 120 mm
REAR WALL P = 120 mm
REAR WALL P = 50 mm
REAR WALL P = 50 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 100 mm
FRONT R = 100 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
AIR STOVE 19,5 KW
AIR STOVE 19,5 KW
PELLET STOVES 6 KW
PELLET STOVES 6 KW
REAR WALL P = 120 mm
REAR WALL P = 120 mm
REAR WALL P = 250 mm
REAR WALL P = 250 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 100 mm
FRONT R = 100 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
AIR STOVE 20,5 KW
AIR STOVE 20,5 KW
PELLET STOVES 9 KW
PELLET STOVES 9 KW
REAR WALL P = 80 mm
REAR WALL P = 80 mm
REAR WALL P = 100 mm
REAR WALL P = 100 mm
SIDE WALL L = 200 mm
SIDE WALL L = 100 mm
SIDE WALL L = 250 mm
SIDE WALL L = 150 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 100 mm
FRONT R = 100 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLET KITCHEN 7,5 KW
PELLET KITCHEN 7,5 KW
PELLET STOVES 7,5 KW
PELLET STOVES 7,5 KW
(free-standing installation)
(free-standing installation)
REAR WALL P = 10 mm
REAR WALL P = 10 mm
REAR WALL P = 180 mm
REAR WALL P = 180 mm
SIDE WALL L = 200 mm
SIDE WALL L = 100 mm
SIDE WALL L = 180 mm
SIDE WALL L = 80 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLET KITCHEN 7,5 KW
PELLET KITCHEN 7,5 KW
PELLET STOVES 11 KW
PELLET STOVES 11 KW
(recessed stove)
(recessed stove)
REAR WALL P = 10 mm
REAR WALL P = 10 mm
REAR WALL P = - mm
REAR WALL P = - mm
SIDE WALL L = 10 mm
SIDE WALL L = 10 mm
SIDE WALL L = - mm
SIDE WALL L = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLET KITCHEN with OVEN 9 KW
PELLET KITCHEN with OVEN 9 KW
PELLET STOVES 12 KW
PELLET STOVES 12 KW
REAR WALL P = 50 mm
REAR WALL P = 50 mm
REAR WALL P = - mm
REAR WALL P = - mm
SIDE WALL L = 50 mm
SIDE WALL L = 50 mm
SIDE WALL L = - mm
SIDE WALL L = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
AIR-TIGHT STOVES 9,5 KW
AIR-TIGHT STOVES 9,5 KW
PELLET STOVES 13 KW
PELLET STOVES 13 KW
REAR WALL P = 50 mm
REAR WALL P = 50 mm
REAR WALL P = 200 mm
REAR WALL P = 200 mm
SIDE WALL L = 150 mm
SIDE WALL L = 50 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLET STOVES 14,5 KW
PELLET STOVES 14,5 KW PELLET STOVES 15 KW
PELLET STOVES 15 KW
REAR WALL P = 200 mm
REAR WALL P = 200 mm
REAR WALL P = 300 mm
REAR WALL P = 300 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
PELLET STOVES with OVEN 8,5 KW
PELLET STOVES with OVEN 8,5 KW
PELLET STOVES SLIM 7,5 KW
PELLET STOVES SLIM 7,5 KW
REAR WALL P = 200 mm
REAR WALL P = 200 mm
REAR WALL P = 10 mm
REAR WALL P = 10 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
SIDE WALL L = 300 mm
SIDE WALL L = 200 mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FLOORING F = - mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
FRONT R = 1000 mm
10
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Eva Calor Diana bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Eva Calor Diana in de taal/talen: Engels als bijlage per email.

De handleiding is 5,83 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Eva Calor Diana

Eva Calor Diana Gebruiksaanwijzing - Nederlands - 38 pagina's

Eva Calor Diana Gebruiksaanwijzing en installatiehandleiding - Nederlands - 90 pagina's

Eva Calor Diana Gebruiksaanwijzing - Deutsch - 38 pagina's

Eva Calor Diana Gebruiksaanwijzing - Français - 17 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info