43
Press the ‘Sleep’ button, after 1 hour the temperature is reduced by 1°C and after
2 hours increased by 2°C.
The device continues operating in this mode.
Water outlet
During the cooling process, the device
removes water from the air. This largely
evaporates but any excess water is collected
in the water reservoir. If the water reservoir
in the device is full, the compressor and the
motor will stop automatically and the ‘water
tank full’ light (W.F.) will come on. In this
event, switch the air conditioning unit off and
remove the plug from the socket. Empty the
water tank by removing the cap from the
water drainage point (see picture) and
draining the tank into a drain or receptacle.
Do not forget to replace the cap again
afterwards! You can then switch the air
conditioning unit back on.
When dehumidifying, more water is
removed from the air. This is why you must connect a hose to the water drainage
hose during dehumidifying and run this to a drain (at a lower point).
LED display
The display shows the configured temperature or the timer settings. If the timer
function is used then the display briefly shows the new values after which the display
returns to the configured temperature.
The display also shows the error codes, see further on in this manual.
Operation via the app
The Cool Perfect WIFI can, via Wi-Fi, also be operated with an app. See the separate
app instruction for this.
Additional comments
When you start the Cool Perfect and opt for a specific function or change function,
the ventilator will work but the compressor will not start immediately: the latter to
protect the internal components. The symbol that belongs to the configured function
blinks on the display, a sign of the ‘waiting mode’. This can last 3 to 4 minutes.
In case of prolonged strong cooling, ice accretion can occur on the interior of the
Cool Perfect. You notice this because the device performs less. To solve this you
switch off the device and give it time to defrost.
When the required cooling or heating temperature has been attained, the Cool
Perfect will continue ventilating but the compressor discontinues operating.