Heatling:
Attach the flexible hose to the hose
connection heating (D) and place it
on the adjustable fins (3).
Attach the round fan blade (E) over
the circular opening (8), see image.
Place the other end of the flexible
hose (with the oval opening) in the
opening in the window kit.
Please note: this device is primarily a
cooler. He can heat when the
ambient temperature is not lower
than 16 ° C, otherwise it will freeze
inside after some time.
Deshumidification:
To dehumidify you must connect a water
drainage hose. To do this, remove button A and
cap B and connect an appropriate hose to
drainage point C with a hose clamp.
Lead the hose to a receiving container or drain,
ensuring that the hose does not run upwards at
any point.
further installation is necessary, even no flexible
outlet pipe.
Warning! Do not use your Cool Perfect until it has been installed according to the instructions
above!
Warning! The length of the outlet pipe is especially designed to suit the Cool Perfect technique.
Do not replace or extend it using another pipe as this could have a negative impact on the
effectiveness of the Cool Perfect. The hose can be stretched but must be kept as short as
possible (max. 40 cm) in order to ensure optimum functioning.
Warning! A small quantity of water can also condense during ‘Cooling’ or ‘Heating’. The device
has a small water tank for this purpose. When it is full the WF light will light up. After 5 minutes
the error code E2 will appear in the display. Empty the tank by connecting a water hose. See
‘Dehumidification’.
Make sure that all connections are secured properly, that the unit is not damaged or broken and
that the socket to which you wish to connect the Cool Perfect is the same voltage as stated on
the device's specification plate. Only use an undamaged, earthed socket that is secured with a
30 mA earth leakage circuit breaker.
If everything is ok, insert the plug into the socket. Your device is ready for use.
.