39
operator’s warehouse or testing facilities. This simplifies the procedure compared to field
configuration on certain locations, especially in case of unfavourable weather conditions.
The configuration of the charging station is performed with the communication interface of the
station, which runs as a web application.
It is recommended that for first few cases, the configuration is performed by the
manufacturer of with their direct help. English translations of all of the configuration tools are
forthcoming.
Step-by-step instructions on how to access the communication interface:
• Connect your computer with an UTP cable to Port 4 of the network switch (if installed)
or directly to the Ethernet connector of the main controller of the charging station.
• The default IP address of the station is 192.168.1.240, which means you have to change
your computer's IP address, for example to: 192.168.1.20. The default subnet mask is:
255.255.255.0.
• Enter the following address into your web browser:
http://192.168.1.240:8002/config/login.html.
• The configuration's interface login window should appear on the screen. The default
login name is: MobilnaElektrika, and the default password is: MobilnaElektrika11.
• Click on the »Login« button which redirects you to the status window.
• In the above navigation bar select the option »Configuration«.
The configuration interface can also be accessed remotely, for example from the Control centre
server. In this case, it is necessary to establish a working communication connection between
the Control centre and the charging station. It is also required to know the IP address of the
station and the TCP port, which uses NAT to redirect the traffic to the TCP port 8002, where the
web application is running.