INSTALLATION
The appliance must be installed by qualified staff working in
accordance with the installation regulations in force.
Before installing, ensure that the appliance is correctly preset
for the local distribution conditions (gas type and pressure).
The presettings of this appliance are indicated on the label shown
on the cover.
This appliance is not connected to a flue gas extractor device.
It must be installed and connected in accordance with the
regulations in force. This appliance may only be installed and
operate in rooms permanently ventilated in accordance with
national regulations in force.
ROOM VENTILATION
The rooms in which gas appliances are installed must be well
ventilated in order to allow correct gas combustion and
ventilation.
The airflow necessary for combustion is at least 2 m
3
/h for each
kW of rated power.
POSITIONING (fig. 3)
Remove the hob from the packaging accessories, including the
films covering the chrome-plated and stainless steel parts. Place
the hob well away from items of furniture with sides higher than
the built-in hob. In addition, any separating wall parallel to the
work surface must be at least 1 cm below the hob casing, and
an opening 10 cm square must be provided underneath the gas
hose elbow. You are advised to make the gas connection before
positioning the hob in the supporting unit.
FIXING
A self-adhesive gasket (A) is supplied with the hob, and must
be placed under the edge of the box unit, as close as possible
to the edge itself (fig. 4). The gasket must fit all the way round
for a perfect seal, preventing moisture from getting beneath the
hob. Place the appliance in the hole in the hob, making sure
that the adhesive gasket provides a firm seal between the edge
of the hob and the surface of the unit (fig. 5), and adjust the
hooks already inserted in the casing (fig. 6).
CONNECTING TO THE GAS SUPPLY
Before connecting the hob, check that it is preset for the gas to
be used. The connection to the appliance is made on the left. If
other heating devices nearby mean there is a risk the hose may
overheat to above 30°C (e.g. if the line passes above another
appliance) a rigid pipe must be used.
Use of a rigid pipe (fig. 7) is compulsory for operation with natural
gas.
CONNECTING TO THE ELECTRICAL MAINS
Before making the connection, check that:
- the mains voltage is as indicated on the nameplate
- the earth connection is in good working order.
If the socket is not easily accessible, the installation engineer
must provide a switch with contact breaking gap of 3 mm or
more.
If the appliance power lead is not fitted with a plug, use an
approved standard type, remembering that:
- the green-yellow wire must be used for the earth connection;
- the blue wire is the neutral;
- the brown wire is live;
- the lead must never touch hot surfaces over 75°C;
- replacement leads must be of type H05RR-F or H05V2V2-F
of suitable size (see fig. 2) for gas and all-electric appliances,
and of type FR3R3 of suitable size (see fig. 2) for mixed
appliances;
- the power supply lead must only be replaced by a qualified
technician.
IMPORTANT: the manufacturer declines all liability for damage
due to failure to comply with the regulations and standards in
force.
Check that the appliance is correctly connected to the earth (see
fig. 2).
FOR HOBS WITH ELECTRIC IGNITION
The correct gap between the electrode and the burner is shown
in figure 9.
If no spark is generated, do not keep on trying as this might
damage the generator. Possible causes of malfunction:
- spark plug damp, dirty or broken;
- electrode-burner gap not correct;
- spark plug wire broken or without sheathing;
- spark discharging to earth (to other parts of the hob);
- generator or microswitch damaged;
- air has built up in the pipes (particularly if the hob has been out
of use for a long time),
- air-gas mixture incorrect (poor fuel setting).
IMPORTANT
- Before carrying out any work inside the appliance, disconnect
the mains plug and shut off the gas tap.
- Never use matches to check for gas circuit for leaks. If a specific
control device is not available, foam or very soapy water can
be used.
- When re-closing the hob, check that the electric wires of the
spark plugs (if present) are not close to the injectors, so that
they cannot run across them.
GB Installation
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Etna EN036V bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Etna EN036V in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0,14 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info