101
INSTALLATION
Electrical connection
The appliance is delivered with a connection
cable. As standard, the connection cable has
a connection between the brown and blue
wires and between the grey and black wires.
In most cases you should remove these
connections.
2 phase connection
2 positive + 2 negative 2 2N a.c. 230 V
Remove the connections.
The fuse box in your home must be fitted with
a 16 A fuse.
negative connection N1 (blue)
negative connection N2 (brown)
positive connection L1 ( grey)
positive connection L2 ( black)
2 positive + 1 negative 2 2N a.c. 400 V
Remove the connection between the grey and
the black wire.
The fuse box in your home must be fitted with
a 16 A fuse.
negative connection N (blue and brown)
positive connection L1 (grey)
positive connection L2 (black)
Do not connect the 3rd phase
The next deviant connections are possible too:
1 phase connection
1 positive + 1 negative 1N a.c. 230 V
The fuse box in your home must be fitted with
a 32 A fuse.
negative connection N (blue and brown)
positive connection L (grey and black)
Electrical connection
The model number, power supply and
connected load are specified on the data
plate.
The data plate is attached to the base of the
appliance.
The connection cable is of the type Y.
This means that the connection cable may
only be replaced by the manufacturer, the
service organisation or similarly qualified
persons, in order to prevent dangerous
situations.
If you want to make a fixed connection, make
sure that a multi-polar switch with a contact
separation of at least 3 mm is fitted in the
supply line.
100
INSTALLATION