WARNINGS
IF WATER DISCHARGES FROM THE
TEMPERATURE/PRESSURE RELIEF VALVE ON
CYLINDER SHUT DOWN THE BOILER. DO NOT
TURN OFF ANY WATER SUPPLY. CONTACT
A COMPETENT INSTALLER FOR UNVENTED
WATER HEATERS TO CHECK THE SYSTEM.
DO NOT TAMPER WITH ANY OF THE SAFETY
VALVES FITTED TO THE SYSTEM. IF A FAULT
IS SUSPECTED CONTACT A COMPETENT
INSTALLER.
BENCHMARK
The cylinder is covered by the Benchmark Scheme
which aims to improve the standards of installation
and commissioning of domestic heating and
hot water systems in the UK and to encourage
regular servicing to optimise safety, efciency and
performance.
Benchmark is managed and promoted by the
Heating and Hotwater Industry Council. For more
information visit www.centralheating.co.uk.
Please ensure that the installer has fully completed
the Benchmark Checklist (Page 22 & 23) of this
manual and that you have signed it to say that
you have received a full and clear explanation of
its operation. The installer is legally required to
complete a commissioning checklist as a means of
complying with the appropriate Building Regulations
(England & Wales).
All installations must be notied to Local Area
Building Control either directly or through a
Competent Persons Scheme. A Building Regulations
Compliance Certicate will then be issued to the
customer who should, on receipt, write the
Notication Number on the Benchmark Checklist.
This product should be serviced regularly to optimise
its safety, efciency and performance. The service
engineer should complete the relevant Service
Record on the Benchmark Checklist after each
service.
The Benchmark Checklist may be required in the
event of any warranty work and as supporting
documentation relating to home improvements
in the optional documents section of the Home
Improvements Pack.
FLOW PERFORMANCE
When initially opening hot outlets a small surge in
ow may be noticed as pressures stabilise. This is
quite normal with unvented systems. In some areas
cloudiness may be noticed in the hot water. This is
due to aeration of the water, is quite normal and will
quickly clear.
TEMPERATURE CONTROLS – DIRECT UNITS
IMMERSION HEATER(S)
A combined adjustable thermostat and thermal
cut-out is provided for each immersion heater. The
thermostat is factory set to give a water storage
temperature of approx. 55°C to 60°C. Access to the
thermostat can be made by opening the immersion
heater cover - DISCONNECT THE ELECTRICAL
SUPPLY BEFORE OPENING THE COVER(S).
Temperature adjustment is made by inserting a at
bladed screwdriver in the slot on the adjustment
disc on top of the thermostat and rotating. The
adjustment range 1 to 5 represents a temperature
range of 12°C to 68°C (60°C will be approximately
position 4). If in any doubt contact a competent
electrician.
DO NOT bypass the thermal cut-out(s) in any
circumstances.
TEMPERATURE CONTROLS - INDIRECT UNITS
The cylinder units are tted with an indirect
thermostat and thermal cut-out. These controls must
be wired in series with the 2 port motorised zone
valve supplied to interrupt the ow of primary water
around the heat exchanger coil when the control
temperature has been reached. The controls are
located within the lower terminal housing along with
the immersion heater thermostat. The thermostat
is factory set to give a water storage temperature
of approx. 55°C to 60°C. Access to the thermostat
can be made by opening the terminal housing
cover - DISCONNECT THE ELECTRICAL SUPPLY
BEFORE OPENING THE COVER. Temperature
adjustment is made by inserting a at bladed
screwdriver in the adjustment knob and rotating. The
minimum thermostat setting is 12°C. The adjustment
range 1 to 5 represents a temperature range of 12°C
to 68°C (60°C will be approximately position 4). If in
any doubt contact a competent electrician.
An immersion heater is also provided for use should
the indirect heat source be shut down for any purpose.
The immersion heater control temperature is set
using the immersion heater thermostat.
DO NOT bypass the thermal cut-out(s) in any
circumstances.
OPERATIONAL FAULTS
Operational faults and their possible causes are
detailed in the Fault Finding section of this book. It
is recommended that faults should be checked by a
competent installer.
The air volume within the expansion vessel will
periodically require recharging to ensure expanded
water is accommodated within the unit. A discharge
of water INTERMITTENTLY from the expansion
valve will indicate the air volume has reduced to
a point where it can no longer accommodate the
expansion.
USER INSTRUCTIONS
16

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elson Zircon bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elson Zircon in de taal/talen: Engels als bijlage per email.

De handleiding is 2,28 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info