621095
13
Verklein
Vergroot
Pagina terug
1/23
Pagina verder
- 25 -
will be shown preceding the number for the default login user. And this login name/password will be the default one each
time the login dialog is shown, so the user doesn’t bother to enter the text to login the system.
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press ENTER to
exit and save, ESC to exit without saving.
Following is a brief description for each item and its specific operations:
Login Name – please follow the Text Input method described in Section 4.1 to modify this item.
P
assword – this item accepts numbers only. Please follow the Text Input method described in Section 4.1 to modify this item.
L
evel – the password level (Administrator, Supervisor, or Operator) for this user. Press +/- buttons to change the level.
6.8 System Setup
In Setup Menu display, press
to change the highlighted option to System, and then press ENTER to call up System Setup as
shown.
The System Setup allows the administrator to set the system time, time zone, time synchronization, language, etc.
The general operations are as below:
▲▼◄►
Press these buttons to select the items.
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press ENTER to exit
and save, ESC to exit without saving. Please note that if the selected language is changed, the user will be asked to reboot the
system for the newly selected language to take effect.
The following is a brief description for each item and its specific operations:
Time Zone – press +/- buttons to select the time zone for the system. Please refer to Appendix B
for the time zone table.
Daylight Saving Time – press ENTER or +/- to check/uncheck this item. The default value is set by selecting a different time
zone, but the user may check/uncheck this item if the default setting is checked.
System Time
Synchronization time synchronized with TSP Server or not. Press ENTER or +/- to check/uncheck this item. The default
setting is “
” - unchecked.
TSP Server TSP (Time Synchronization Protocol) server name if Time Synchronization is enabled. The system will try to do
time synchronization with the specified TSP server at the system preset interval. Please follow the Text Input method described
in Section 4.1
to modify this item.
Date – system date. Press +/- buttons to modify each of these items.
Time – system time. Press +/- buttons to modify each of these items.
Display Format format used for the system time displayed on the lower-left corner of the main screen. Press +/- buttons to
select the desired format.
Language press +/- buttons to select the language for the system. The languages supported include: English, Russian,
Simplified Chinese, Italy Portugal ,etc.
6.9 RS-232/422/485 Setup
- 26 -
In Setup Menu display, press
to change the highlighted option to RS-232/422/485, and then press ENTER to call up
RS-232/422/485 Setup as shown.
The RS-232/422/485 Setup allows the administrator to setup RS-232 control port, and RS422 or RS-485 control port. Please refer
to the manuals for the connected devices - PTZ cameras – to set these items in RS-232/422/485 Setup.
The general operations are as follows:
▲▼
Press these buttons to select the items.
MODE
Press this button to call up Optional RS-232 Setup screen if it’s built in the DVR. The operations for Optional RS-232 Setup
are the same as RS-232/422/485 Setup.
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press ENTER to
exit and save, ESC to exit without saving.
The following is a brief description for each item and its specific operations:
Device Type PTZ or N/A (Not Available). Press +/- buttons to change the type. Please note that PTZ can only be
selected for either RS-232 or RS-485, but not both.
Model PTZ model of the connected devices. The PTZ models supported include Pelco D protocol Dome, SamSung
SCC-641P, etc. Press +/- buttons to change the supported model (or protocol).
Baud Rate – press +/- buttons to change the value.
Data Bit – press +/- buttons to change the value.
Stop Bit – press +/- buttons to change the value.
Parity – (Odd, Even, or None). Press +/- buttons to change the value.
DVR/Camera ID for PTZ => the device ID for this digital video/audio recorder, and it must not conflict with the other
devices connected in the same control port. Press +/- buttons to change the ID.
6
.10 Network Setup
In Setup Menu display, press
to change the highlighted option to Network, and then press ENTER to call up Network Setup
as shown.
The Network Setup allows the administrator to setup all Ethernet network related parameters. Please check with your network
a
dministrator to set these parameters correctly. For most home users, the typical configuration would connect the DVR to a router
to the internet. In those cases, please see your router user manual for details on how to port forward data and controls to/from the
router to the DVR. In addition, most home users will have dynamic IP addressing. Please use a dynamic DNS service, such as
http://www.dyndns.com
to access your router and DVR from the internet.
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elro DVR154S bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elro DVR154S in de taal/talen: Engels als bijlage per email.

De handleiding is 1,54 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Elro DVR154S

Elro DVR154S Gebruiksaanwijzing - Nederlands - 22 pagina's

Elro DVR154S Gebruiksaanwijzing - Deutsch - 24 pagina's

Elro DVR154S Gebruiksaanwijzing - Français - 19 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info