- 9 -
sure to setup the related configurations as described in Section 6.10 Network Setup.
USB 2.0 disk drives, card reader, etc.
If the user wants to use USB2.0 peripheral device to retrieve important recorded images and/or audio, please connect it to the
USB port connector.
I/R remote control
The user may use I/R remote control to control the digital video/audio recorder.
PTZ Cameras
Connect the RS-485 connector to PTZ camera(s) via the appropriate cable. The system supports a variety of different PTZ
cameras, including Pelco D protocol Dome, SamSung SCC-641P, etc. But different PTZ cameras can coexist in a system only
if they support the same protocol. Please make sure to set the PTZ ID of the camera(s), and setup the camera (RS-422/485
(Section 6.9
) accordingly.
4. Main Screen And Basic Operations
The split-window screen, as shown above, is the main screen after system startup. There are two types of split-window screens,
including 1-Window and 4-Window. The system will remember the last one before normal shutdown (as described in Section 5.6)
of the system. In addition to the split windows, the system time is displayed on the lower-left corner, the system states on the
lower-right corner, and the rolling screen messages, if shown while certain event occurs, on the lower corner.
The system states, from right to left, are described as the followings:
(1) Normal recording percentage,
(
2) Alarm recording percentage,
(3) Mute state – speaker icon shown for unmute, not shown for mute,
(4
) X2 state – X1, X2, or X4,
(5) Manual record ON/OFF – REC icon shown for ON,
(6) Backup state – Backup icon shown for backup,
(7) SEQ display ON/OFF or playback state – SEQ icon shown for SEQ display ON, other icons for different playback states.
4.1 Text Input (Please match with a remote control usage)
T
here are certain circumstances that the system requires the user to enter text, such as system login, camera title setup, and so on.
Please follow the steps below to enter text:
(1) Press ENTER to edit the highlighted option. The flashing cursor will be shown to indicate the editing point. Besides, a keypad
hint will be shown as below.
(
2) Press ◄► to move the cursor to the left/right.
(3) Press code in text editing mode to change text case. (If this entry can accept number only, pressing code will have no effects.)
Indicators on the screen show the current setting:
123 = Number only
abc = No capital letters
ABC = All capital letters
CODE = Internal code for the selected language, such as Chinese, Japanese, etc.
(4) Press a number key (1-9, 0) repeatedly until the character you want appears. (1 for 1 or space, 2 for 2, a/A, b/B, or c/C,
for 5, j/J, k/K, l/L, M
UTE for 6, m/M, n/N, o/O, the others as shown on the keypad hint) If internal CODE is selected, a
CODE line will be added (after the first code is entered) for each new code to be entered. Please check the internal code table
for the selected language. For 2-byte code, e.g. Chinese or Japanese, the code accepted is from 0000 - FFFF.
36%
- 10 -
(5) Press mark to bring up a list of punctuation marks and special characters. The highlighted character in the list shows the
selected one. Press ▼◄► to change the selection.
(6) If you make a mistake, press BS to remove the character to the left of the cursor, or press DEL to delete the character at the
current cursor position.
(7) In text editing mode, internal code box, and mark list, press ENTER to exit and save changes, press ESC to exit without
making changes.
4.2 Login And Logout
There are three password levels in the system, including Administrator (highest), Supervisor, and Operator (lowest). If the user
does not login the system, he/she will be treated as “Guest” and can only view live video display.
The system allows up to 18 user accounts. The administrator can set up the login name and password for each user. (Please refer to
Section 6.7
for Password Setup.)
The Operator can operate live video display, the Supervisor live video display, image playback and archive, and the Administrator
everything.
To login/logout the system, press MENU in split-window display
to
call up Menu display, and then press ENTER when the
highlighted option is Login/Logout to enter Login/Logout display as
shown.
In Login/Logout display, follow the Text Input method described in
Section 4.1 to enter the Login name and Password, press to
highlight and select Login option, and then press ENTER to login
the
system. If the user wants to logout the system, just press to
highlight and select Logout option, and then press ENTER. Press ESC to exit without making changes.
There is one factory-preset login name/password aa/11 at Administrator level. The user can use it to login the system for the first
time.
Should the user have forgotten all the administrator-level passwords, please contact the local dealer or installer to recover
from it.
4
.3 Basic Operations
The basic user’s operations after he/she has logged into the system are described below:
Numeric
Press these buttons to switch to the full-window display for the camera.
Alarm Reset
Press this button to cancel alarm activation, i.e. reset the alarm outputs and silence the buzzer.
MODE (Administrator/Supervisor)
In split-window display, press this button to change circularly the live/playback mode for the focus window and the other
windows that form a rectangle on the screen.
S
EQ
Press this button to switch to or return from SEQ display mode. In SEQ display mode, each page in the sequence will be
shown for the preset page dwelling time sequentially, and SEQ icon will be shown on the lower-right corner of the screen.
SEARCH (Administrator/Supervisor)
In split-window display, press this button to display the search menus. The system will remember the last one the user chose.
REC
Press this button to force manual recording. To stop manual recording, press it again. All cameras will be recorded as if the
scheduled record is A/V, and REC icon will be shown on the lower-right corner of the screen if manual recording is ON.
MENU / ESC
In split-window display, press this button to display the versatile menu.
Stop (
) / PTZ
In split-window display, press this button to enter PTZ control mode if the focus camera is a PTZ camera.
X
2
In full screen display, press this button to enter Digital Zoom mode. Please refer to Section 4.4 Digital Zoom
for the detailed
operations in Digital Zoom mode.
▼◄►
Press these buttons to move focus. The title of the camera for the focus window is highlighted as shown on the screen.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elro DVR154S bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elro DVR154S in de taal/talen: Engels als bijlage per email.

De handleiding is 1,54 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Elro DVR154S

Elro DVR154S Gebruiksaanwijzing - Nederlands - 22 pagina's

Elro DVR154S Gebruiksaanwijzing - Deutsch - 24 pagina's

Elro DVR154S Gebruiksaanwijzing - Français - 19 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info