Strobe
light &
red LED
Control Box
hidden under
water proof cover
(below)
e
Control
box
cover
r
AS80SR11B
Solar Siren
Installation Instructions
General Introduction
The AS80SR11B is an outdoor siren powered by solar energy and rechargeable
battery. By its visible presence, the external siren indicates that an alarm system is
installed and deters intruders. In case of intrusion, it alerts the neighborhood by its
powerful 110 decibels piercing sound and a flashing red light
Product Overview
FRONT VIEW
Binding
1.
Open up the siren by removing the fixing screw from the bottom edge and carefully
peeling off the back cover. All electronic components are housed within the front
cover.
2.
A 9V Alkaline battery is supplied to boost the initial power to the unit when it is first
activated until the Solar Panel charges the main battery. Locate the battery clips of
this 9V battery but do not connect it up yet.
3.
Log into the ELRO Smart Home Alarm account from a web browser.
4.
Select “System”.
5.
Select “Add a New Device”, then “Solar Siren”.
Solar Panel
6V 1.2Ahr
rechargeabl
battery
9V initial powe
up battery
INSIDE VIEW OF SIREN MAIN BODY
(BACK COVER REMOVED)
6.
The following screen will appear. This means the gateway is entering binding mode.
2
7.
Connect the 9V battery to its battery clips to power up the siren.
8.
The screen below will appear in 10 seconds if the process is successful.
Note: Time-out will occur if the binding process was unsuccessful. Please refer to
the “Manual Binding” in the Troubleshooting section.
9.
Next connect the main rechargeable battery to the charging leads. Connect the
Red lead to the Red (+ve) terminal and the Black lead to the Black (-ve) terminals.
10.
The siren is now ready however do not refit the back cover just yet.
Operation & Testing
IMPORTANT: The loud sound level produced by this device will be deafening and
cause discomfort to the ear. Place the siren outdoors and do not stand in close
proximity to the siren.
Note: It is strongly advised to have the keyfob or keypad ready to quickly Disarm
the system to turn off the siren.
1.
Assemble the back cover back to the main body without screwing the fixing screw
at the bottom.
2.
Place the siren facing up on a flat surface so that the protruding tamper switch is
pressed.
3.
Set the system to Arm mode and trigger the alarm. The siren will emit a loud
piercing sound and the strobe light will flash brightly.
4.
Quickly disarm the system to stop the siren.
Mounting
The Siren should be mounted:
-
as high as possible in a prominent position so that it can be easily seen and heard.
-
on a flat surface so that the rear tamper switch is not easily activated. Ensure also
that the tamper switch does not fall into the recess between brick courses as this
could prevent the switch from closing and give a permanent tamper signal.
-
ideally on a south facing wall to receive optimum amount of sunlight, but an east or
west facing wall will also suffice. Avoid mounting on a north facing wall, and avoid
shadows cast by neighboring walls, trees, and roof overhangs.
-
at least 1 meter away from any external or internal metalwork which can affect its
radio transmission.
Installation
To install the siren on the wall, first affix its back cover on the wall and then followed by
mounting its main body onto the back cover.
3
1.
Remove the back cover again. Using the back cover itself as a template, position
the back cover on the wall and mark the positions of four mounting holes.
2.
Drill four 6mm holes and insert the wall plugs.
3.
Fit two 30mm fixing screws in the top holes leaving approximately 10mm of the
screw protruding.
4.
Place the top keyhole slots of the back cover over the screw heads. Adjust the
back cover position and adjust the screws until they form a neat fit with minimal
movement.
5.
Secure the back cover in position using the two 25mm fixing screws at the bottom.
Fit two 30mm fixing screws in
the top holes leaving
approximately 10mm of the
screw protruding
Secure back cover using
two 25mm fixing screws at
the bottom
6.
Before mounting the main body, ensure the waterproof cover of the Control box
has been secured back if it was removed earlier.
10.
To mount the main body, hinge the front cover tabs over the top edge of the back
cover and carefully push the base of the siren cover into place. Secure the main
body in place by refitting the fixing screw in the bottom edge of the cover. Do not
over tighten the screw as this could damage the thread.
IMPORTANT: Ensure that the rear tamper switch is closed when the main body is
fitted (i.e. listen for the switch to click). If the switch does not close, this will prevent
the Siren from operating correctly. If necessary, remove the main body again and
adjust the screw on the back cover tamper plunger to ensure the switch closes
when the siren is secured in position.
11.
Upon completion of mounting the main body on the wall, the Strobe LED will flash
about 3 seconds as an indication of normal operation.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact
your original retailer or nearest service center if the below solutions cannot solve your
problem.
Symptom
Cause of Failure
Recommendation
LED cannot be
displayed
1.
Run out of battery
power.
2.
Check if reverse
battery polarity.
3.
Siren is out of order.
1.
Replace a new battery.
2.
Refit the battery with correct
polarity.
3.
Do not open the device and
send it for repairs.
The LED on the
siren is operating,
but it cannot be
operated
1.
Check if siren has
completed binding
with Homesys
Gateway
2.
The siren cannot
communicate with
the gateway.
Remove both the battery and
follow the steps for binding
with ELRO Smart Home Alarm
1.
Locate the siren closer to the
gateway.
Back
Cover
4
Manual Binding
1.
Locate the Control Box area and remove its waterproof cover by unscrewing it.
Identify the Link button inside.
Link Button
2.
With the 9V battery still connected, repeat steps 5 to 6 of the Binding with ELRO
Smart Home Alarm
section.
3.
Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.
4.
Within 5 seconds the Strobe LED will stop flashing and turn off, indicating the
binding procedure is completed. The screen below will appear to confirm this.
Reset to Factory Settings
1.
Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.
2.
Press and hold the Link button again for more than 6 seconds until the Strobe
LED turns off, then release. The LED will flash every 2 seconds indicating the
siren is now reset back to factory mode factory.
Jumper Settings
The siren preset settings can be modified by adjusting the jumper settings inside its
Control Box.
1.
Locate the Control Box area and remove its waterproof cover by unscrewing it.
2.
Identify the set of jumper links JP1. The settings for each is described below:
JP1 Settings
JP1
Position
Jumper fitted
Jumper removed
ALARM
Alarm sound enabled
Alarm sound disabled
CU
Must be fitted
N/A , factory use only
1MIN
1 minute alarm sound
3 minute alarm sound
ANTI
Anti-jamming enabled
Anti-jamming disabled
BEEP
Beep sound enabled
Beep sound disabled
Control
Box
Cover
Alarm
C.U.
1
MIN
A.J.
Beep
5
LED Table
The table below describes the LED indication at various stages of Siren operation
Status
Strobe LED Indication
Audible indication
Full alarm
Strobe light flashes brightly
Siren piercing sound
Installation is ok
(Press tamper
switch once
after binding)
LED flashes for 3 seconds
Factory reset
LED flash every 2 seconds for
one minute
Low battery
indication
LED flashes 20 times rapidly
Specifications
Battery
6V 1.2Ah Lead acid, 9V PP3 alkaline
Operating Temperature
-10°C to 60°C
Working Range
Minimum 200 meters
Siren Volume
Minimum 100dB / 1 meter
Operating Frequency
868MHz
** Specifications are subject to change without notice.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities.
Contact your local government for information regarding the collection systems
available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging your health and
well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take
back your old appliance for disposal at least for free of charge.
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elro AS80SR11B bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elro AS80SR11B in de taal/talen: Engels als bijlage per email.

De handleiding is 0,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info