9. When alarm occurs
An alarm condition will be triggered when, in Fully Arm/Partial mode, a sensor is
triggered and signals the panel to sound the alarm.
The alarm will also be triggered under an emergency panic situation, when the panic
button on the remote keyfob is pressed, or the alarm panel keypad registers a panic
(long press 9 key).
When an alarm is triggered the following actions will take place:
- the siren will sound loudly (depending on your Alarm Type and Alarm Time
settings). The default time for siren alarm is 3 minutes.
- the Alarm LED will flash. LEDs 1 – 9 will also indicate which of the Sensor Zones
1 – 9 caused the alarm, or which Remote 1 – 9 activated the panic. LED 0 will
turn on for other situations. The LEDs will continue to be on until the system is
disarmed.
- SMS notification will be sent to contacts (depending on your SMS setting).
- Voice call will be made to contacts (depending on your Alarm message setting).
To quickly turn off the above activity, disarm the system by entering PIN + DISARM
Key, or using the remote keyfob. This will also clear Alarm Memory.
9-1 Voice call alert
During an alarm condition the alarm panel will initiate a voicecall session, during
which it will repeatedly dial the preset voicecall telephone numbers in sequence and
play back the recorded help message.
- For each contact called the alarm message will playback repeatedly for 30
seconds. The next contact will then be called.
- Each contact will be called 3 times in a call loop regardless whether the call is
answered or not.
- To end the current call, press the “*” key then “#” key on the phone, or wait 30
seconds timeout. The alarm panel will then call the next contact on the list.
- To exit from the call loop, press the “*” key then “8” key. This contact will not be
called again until the next alarm condition.
- If 3 contacts exit the call loop (i.e. 3 contacts entered “*” then “8” key), the entire
call session will end abruptly.
9-2
Phone control mode
When called, the user may press the “*” key on the phone. This will stop the
siren and the panel will enter phone control mode to wait for next input key:
a. Press “1” key = Fully Arm and send SMS
b. Press “2” key = Part-Arm and send SMS
c. Press “3” key = Set the Siren to turn on Alarm and send SMS
d. Press “4” key = Set the Siren to turn off Alarm and send SMS
e. Press “6” key = Listen to the Alarm message again
f. Press “7” key = Enter Listen-In Mode. This mode will timeout after 5 minutes.
Press the “#” to exit Listen-In at anytime.
g. Press “8” key = Exit from call loop and send SMS
h. Press “9” key = Enter Two Way Talk Mode. This mode will timeout after 5 minutes
i. Press “0” key = Disarm and send SMS
j. Press “#” key = Cancel this call without exiting the call loop.
If no keys are input after 30 seconds, the alarm panel will hang up.
9-4 RFID Tag Disarm Notification
If the alarm is disarmed by the RFID Tag, an SMS will be sent to the Host Phone
Number is set to Disarm and notify which RFID tag user disarmed the system.
10. Other types of alerts
10-1 RF Jamming detection
When Anti-jamming is set to on, the device will send an SMS to the Host Phone
Number when RF jamming is detected under Arm Mode
.
10-2 Sensor Low Battery Indication
When a sensor’s battery runs low, an SMS will be sent to Host Phone Number
(The sensor will send a second SMS after a minimum interval of 7 days).