ELM327
ELM327DSJ Elm Electronics – Circuits for the Hobbyist
www.elmelectronics.com
AT Command Descriptions (continued)
Values passed in this way do not affect those that
are stored in the 2C and 2D Programmable
Parameters, and are lost if the ELM327 is reset. If you
want to make your settings persist over power cycles,
then you may wish to store them in the Programmable
Parameter for CAN protocols USER1 or USER2.
PC [ Protocol Close ]
There may be occasions where it is desirable to
stop (deactivate) a protocol. Perhaps you are not using
the automatic protocol finding, and wish to manually
activate and deactivate protocols. Perhaps you wish to
stop the sending of idle (wakeup) messages, or have
another reason. The PC command is used in these
cases to force a protocol to close.
PP hh OFF [ turn Prog. Parameter hh OFF ]
This command disables Programmable Parameter
number hh. Any value assigned using the PP hh SV
command will no longer be used, and the factory
default setting will once again be in effect. The actual
time when the new value for this parameter becomes
effective is determined by its type. Refer to the
Programmable Parameters section (page 69) for more
information on the types.
Note that ‘PP FF OFF’ is a special command that
disables all of the Programmable Parameters, as if you
had entered PP OFF for every possible one.
It is possible to alter some of the Programmable
Parameters so that it may be difficult, or even
impossible, to communicate with the ELM327. If this
occurs, there is a hardware means of resetting all of
the Programmable Parameters at once. Connect a
jumper from circuit common to pin 28, holding it there
while powering up the ELM327 circuit. Hold it in
position until you see the RS232 Receive LED begin to
flash (which indicates that all of the PPs have been
turned off). At this point, remove the jumper to allow
the IC to perform a normal startup. Note that a reset of
the PPs occurs quite quickly – if you are holding the
jumper on for more than a few seconds and do not see
the RS232 receive light flashing, remove the jumper
and try again, as there may be a problem with your
connection.
PP hh ON [ turn Programmable Parameter hh ON ]
This command enables Programmable Parameter
number hh. Once enabled, any value assigned using
the PP hh SV command will be used where the factory
default value was before. (All of the programmable
parameter values are set to their default values at the
factory, so enabling a programmable parameter before
assigning a value to it will not cause problems.) The
actual time when the value for this parameter becomes
effective is determined by its type. Refer to the
Programmable Parameters section (page 69) for more
information on the types.
Note that ‘PP FF ON’ is a special command that
enables all of the Programmable Parameters at the
same time.
PP hh SV yy [ Prog. Param. hh: Set the Value to yy ]
A value is assigned to a Programmable Parameter
using this command. The system will not be able to
use this new value until the Programmable Parameter
has been enabled, with PP hh ON.
PPS [ Programmable Parameter Summary ]
The complete range of current Programmable
Parameters are displayed with this command (even
those not yet implemented). Each is shown as a PP
number followed by a colon and the value that is
assigned to it. This is followed by a single digit – either
‘N’ or ‘F’ to show that it is ON (enabled), or OFF
(disabled), respectively. See the Programmable
Parameters section for a more complete discussion.
R0 and R1 [ Responses off or on ]
These commands control the ELM327’s automatic
receive (and display) of the messages returned by the
vehicle. If responses have been turned off, the IC will
not wait for a reply from the vehicle after sending a
request, and will return immediately to wait for the next
RS232 command (the ELM327 does not print anything
to say that the send was successful, but you will see a
message if it was not).
R0 may be useful to send commands blindly when
using the IC for a non-OBD network application, or
when simulating an ECU in a learning environment. It
is not recommended that this option used for normal
OBD communications, however, as the vehicle may
have difficulty if it is expecting an acknowledgement
and never receives one.
An R0 setting will always override any ‘number of
responses digit’ that is provided with an OBD request.
The default setting is R1, or responses on.
23

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Elm-327

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elm 327 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elm 327 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,23 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info