Battery and flat battery detection
The detector is powered by three AA 1.5 V lithium batteries.
When the detector battery is flat. When the battery voltage is flat, the detector transmits the flat battery signal to the control unit.
If a flat battery condition is detected, the blue LED lights up for two seconds.
While replacing the batteries, after having removed the flat batteries, press the tamper button or the function button twice to
discharge the device completely before inserting the new batteries.
<
<
N
N
O
O
T
T
E
E
>
>
During replacement, pay particular attention not to damage the contacts in the battery holder compartment.
Tamper protection
The detector is protected by a tamper switch and is normally compressed against a wall or a surface. When the cover of the
detector or the entire detector is removed from the installation surface, the tamper switch is opened and the detector sends a
tamper open signal to the control unit to inform the user. If a motion is detected while the tamper switch is open, the blue LED
lights up for two seconds.
The detector does not detect the tamper switch state for five minutes after the battery is inserted.
If the tamper switch is operated in the five minutes during which there is no detection, the detector will immediately
transmit a tamper signal to the control unit.
It is not possible to restore factory settings (see paragraph dedicated) with the switch tamper pressed.
<
<
N
N
O
O
T
T
E
E
>
>
During installation, be particularly careful not to misplace the rubber cap mounted on the tamper switch.
Supervision
The detector regularly transmits a supervision signal to indicate the condition according to the user's setting. The default setting
is 30 minutes. The user may also press the function button once to manually transmit the supervision signal.
Test mode
Test mode is used to control the detection coverage of the device not the wireless communication range with the control unit.
To access test mode, hold the function button pressed for a few seconds then release it to start the test mode that lasts for three
minutes.
The detector will start initialisation during the first 30 seconds. It is advisable not to generate alarms during this time.
Motion detection in front of the detector can be checked at the end of the initialisation period. The blue LED lights up for two
seconds after detection.
Setup
Guidelines
- Check that the control unit is working before inserting the batteries in the device.
- Check that the control unit is within the working range while the device is in use.
- A device may be removed from the system only after having removed the battery.
Connecting to the system
The detector must be learnt by the control unit to transmit the signal if motion is detected. To run the device leaning procedure on
the control unit, proceed as follows.
The detector may be learnt by the control unit only within three minutes from when it is switched on.
1. Insert the batteries into the compartment on the back of the detector.
2. The tamper switch must be open (released).
3. Enable learning mode on the control unit. Within three minutes from switch-on, hold the function button pressed for
10 seconds and then release it when the blue LED blinks once.
4. After having been leant by the control unit, the detector is automatically recorded in the system. Check the control unit
to check that the learning and registration procedure were performed correctly.
5. Once learnt by the control unit, if the detector connection is lost, the LED will blink once every 20 minutes to signal the
fault.
Restoring default settings
If the detector has not been learnt correctly by the control unit, or if you want to remove it and associated to another control unit,
restore the default settings to eliminate the settings and the information stored in the detector before being able to associate it
with another control unit.
To restore the default settings:
1. Remove the batteries and refit them. WARNING: The detector must be reset within three minute from switch-on.
2. The tamper switch must be open (released).
3. Hold the function button pressed for 10 seconds, then release it as soon as the blue LED blinks once.
4. The detector was reset to the default factory settings and all the previous network information were deleted. The
detector is no longer present on the "Devices" page.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elkron IR600VC bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elkron IR600VC in de taal/talen: Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 0,75 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Elkron IR600VC

Elkron IR600VC Snelstart handleiding - Deutsch, English, Français, Italiano - 8 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info