Ensure that the appliance is switched off before replacing the lamp to avoid the
possibility of electric shock. Only use the correct lamp E14 230V 20W 300ºC.
ELECTRICAL CONNECTION (UK ONLY)
For your safety please read the following information.
Warning: This appliance must be earthed.
The appliance must be connected to a 220-240 volts 50 cycle AC supply
by means of a three pin socket, suitably earthed and should be protected by
a 13 amp fuse in the plug.
The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with
a 13 amp fuse. Should the fuse require replacement, it must be replaced with
a fuse rated at 13 amp and approved to BS1362.
The plug contains a removable fuse cover that must be refitted when the
fuse is replaced. In the event of the fuse cover being lost or damaged, the
plug must not be used until a replacement cover has been obtained.
If the mains plug is unsuitable for the socket outlet in your home or is
removed for any other reason, then the fuse should be removed and the
cut off plug disposed of safely to prevent the hazard of electric shock.
There is a danger of electric shock if the cut off plug is inserted into any
13 amp socket outlet.
How to wire a 13 amp plug.
Important
The wires in the mains lead on this appliance are coloured in accordance
with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
As the colours may not correspond with the markings identifying the terminals
in your plug proceed as follows.
The green and yellow wire must be connected to the terminal in the plug which
is marked withthe letter E or with the earth symbol or coloured green and yellow.
The blue wire must be connected to the terminal marked N or coloured black.
The brown wire must be connected to the terminal marked L or coloured red.
You must make sure the mains cord is held securely under the cord clamp