646315
47
Verklein
Vergroot
Pagina terug
1/60
Pagina verder
7
Operation
Main functions of the control panel
Button Action Procedure Display / Function
Setting up the required
room temperature
HK2 jointly with HK1
Turn the rotating button left or right
Turn the rotating button again for
storing with OK button
or wait for 5 sec.
or push
comfort target value with blinking temperature display
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort value active
Comfort value not active
- Basic display appears after 3 sec.
Setting the required room temperature
for HK1 or HK2
or
2nd HK independent of HK1
Turn rotating button left/right
Then push OK
Turn rotating button left/right
Save with OK button
or wait for 5 sec.
or push
Select heating circuit
Heating circuit active
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort target value active
Comfort target value not active
- Basic display appears after 3 sec.
Switching warm water operations ON
or OFF
Push button Warm water operation ON / OFF
(segmented bar under symbol for warm water visible/invisible)
- ON: Warm water preparation according to switching program
- OFF: No warm water preparation
- Safety function active
Change operating mode
Factory setting
1 x short push of button and then
once more, short push of button
Automatic operating mode ON, with:
- heating operation according to timer program
- Temperature target values according to heating program
- Safety function active
- Summer/Winter - automatic switching active
- ECO functions active
(segmented bar under corresponding symbol visible)
Continuous COMFORT heating ON, with:
- Heating operation without timer program, at comfort target value
- Safety function active
Continuous REDUCED heating ON, with:
- Heating operation without timer program, at reduced target value
- Safety function active
- Summer/Winter - automatic switching active
- ECO functions active
Automatic safety mode ON, with:
- Heating operations switched off
- Temperature according to frost protection value
- Safety function active
Control stop function
1 x push button (> 3 sec)
push button once more (> 3 sec)
304: Control stop function Set target value
Basic display appears after 3 sec.
Display of various
information
1 x push button
push button again
push button again
Push button
INFO section is displayed
- Boiler status - Room temperature
- Room temperature minimum
- Warm water status - Room temperature maximum
- Status heating circuit 1 - Outdoor temperature
- Status heating circuit 2 - Minimum outdoor temperature
- Maximum outdoor temperature
- Time / date - Water temperature 1
- Error message - Boiler temperature
- Maintenance report - Flow temperature
(Display of the information lines depends on the conguration)
Back to basic display; INFO segment is suppressed
Operating mode according to
target values that are
set manually
Change of the factory setting
for boiler temperature
short push of button
short push of button
short push of button
Rotating button turn -/+
short push of button
short push of button
short push of button
Manual operating mode ON (spanner symbol is visible)
- Heating operations at preset boiler temperature (factory setting = 60°C)
301: Manual operation mode Set target value for manual
operation?
Blinking temperature display
Set required target value
Boiler status
Manual operating mode OFF (spanner symbol disappears)
De-aeration function 1 x push button (> 3 sec)
push button once more (> 3 sec)
312: De-aeration function ON
De-aeration function OFF
Activation of chimney sweep function Push button (> 3 sec)
push button once more (> 3 sec)
Chimney sweep function ON
Chimney sweep function OFF
Short-term reduction of room
temperature at QAA75 / 78
Push button
push button again
Heating at reduced target value
Heating at comfort target value
RESET
Reset button Push button (< 3 sec.) push button
again > 3 sec.
Facility is manually locked, unreleased equipment is unlocked, alarm bell
disappears
= Conrmation
= Abort or back to basic display
47

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elco THISION S PLUS Combi bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elco THISION S PLUS Combi in de taal/talen: Duits, Engels, Italiaans als bijlage per email.

De handleiding is 1,21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info