7.3. Spark plug
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark plug
after every 50 hours of operation.
앬 Pull off the spark plug boot with a twist.
앬 Remove the spark plug with the supplied spark
plug wrench.
앬 Assemble in reverse order
7.4 Changing the oil and checking the oil level
(before using the machine)
The motor oil is best changed when the motor is at
working temperature.
앬 Only use motor oil (15W40).
앬 Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
앬 Open the oil filler plug.
앬 Open the oil drain plug and let the hot engine oil
drain out into a drip tray.
앬 After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
앬 Fill in engine oil up to the top mark on the oil dip
stick.
앬 Important: Do not screw the dipstick in to check
the oil level, simply insert it up to the thread.
앬 Dispose of the waste oil properly.
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too little
oil in the engine. In this case it will not be possible to
start the engine or it will cut out automatically after a
short period of time. It cannot be started again until
the engine oil has been topped up.
7.6 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
GB
17