GB
10
앬 The equipment is not designed for installation in
laundries.
앬 The equipment must be positioned in such a way
that the mains plug is accessible at all times.
앬 The temperature in the cooling circuit may
become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
Function principle – heating
In heating mode, heat is removed from the outdoor
air by the outdoor device and fed into the indoor
device. This passes the heat on to the room which it
is to heat. Electrical energy is required for this. In
certain circumstances condensation may be
produced on the outdoor device, which must be
discharged via the condensation drain on the
underside of the outdoor device.
Inverter
In both modes of operation, the compressor capacity
adjusts to the demand and regulates the nominal
temperature with minimum temperature fluctuations.
This “inverter technique” saves energy compared to
conventional split air-conditioning systems.
2. Items supplied
1 indoor device (box 1, art. no. 23.654.08)
1 outdoor device (box 2, art. no. 23.654.09)
1 set of installation accessories (for details, see page
18)
3. Technical data
Cooling capacity 3400 watts
Heating capacity 3900 watts
Energy efficiency A (EER 3.30/COP 3.71)
Air capacity 675 m
3
/h
Absorbed humidity (30°C/80% RH) 1.2 l/h
Timer 24 h
Operating voltage 220 - 240 V ~ 50 Hz
Socket fusing 16 A
Nominal power consumption, cooling 1030 watts
Nominal current consumption, cooling 4.9 A
Nominal power consumption, heating 1050 watts
Nominal current consumption, heating 4.7 A
Compressor Rotary piston
Compressor starting current 7,3 A
Outdoor temperature, cooling operation °C
+18 - + 43 (DB)
Outdoor temperature, heating operation °C
-7 - + 24 (DB)
Fluid line Ø A 6,35 mm
Suction pipe Ø A 12,7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1230 g
Refrigerant refill quantity from 5 m 25 g/m
Sound pressure level
Inside ≤ 43 dB (A)
Outside ≤ 54 dB (A)
Dimension Inside 81,5 x 28 x 21,5 cm
Dimension Outside 78 x 59 x 31,5 cm
Weight Inside 9,5 kg
Weight Outside 39,5 kg