ENGLISH
INTRODUCTION ON INSTALLATION INTRODUCTION ON INSTALLATION
Remember that:Remember that:
the product must be installed by qualified staff the product must be installed by qualified staff
who can issue a Declaration of Conformitywho can issue a Declaration of Conformity
all the local and national laws and the European all the local and national laws and the European
Standards must be met for installation and use of Standards must be met for installation and use of
the product.the product.
In the event of installation in apartment blocks, ask In the event of installation in apartment blocks, ask
the administrator’s opinion beforehand.the administrator’s opinion beforehand.
We give some general instructions below, however We give some general instructions below, however
these do not obviate the need to comply with local these do not obviate the need to comply with local
regulations and do not affect the installer’s liability for regulations and do not affect the installer’s liability for
the installation.the installation.
INSTALLATION
CHIMNEY SYSTEM CHIMNEY SYSTEM
(Smoke channel, chimney flue and chimney (Smoke channel, chimney flue and chimney
stack)stack)
This chapter is drafted according to the European
Standards EN 13384, EN 1443, EN 1856, EN 1457. The
installation technicians must take into consideration
these and any other local standards. The manual
should in no way be considered a replacement for the
laws in force.
The product must be connected to a suitable smoke
discharge that guarantees completely safe evacuation
of the smoke produced by combustion.
Before positioning the product, you need to check the
chimney flue is suitable.
SMOKE CHANNEL, CHIMNEY FLUESMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fireplace with the chimney flue inlet) and the
chimney flue must, along with other legal provisions:
receive the discharge for a single product (multiple
product discharges are not permitted together)
have a mainly vertical development
no section should have a reserve slope
have an inner section preferably circular and
however with a ratio between sides lower than 1.5
complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
be created with materials with a fire reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
be appropriately certified, with an appropriate
fireplace plate, if metal
keep the initial section
The hot air can circulate naturally The hot air can circulate naturally
(natural convection) or with the aid of a (natural convection) or with the aid of a
ventilation system (AIR DIFFUSER KIT) ventilation system (AIR DIFFUSER KIT)
to be purchased separately and applied to be purchased separately and applied
BEFORE completing the installation BEFORE completing the installation
process. process.
Contact your retailer for any further Contact your retailer for any further
information.information.
Checking the suitability of the installation
premises
The volume of the room must be over 40 m3
Installation is not permitted in bedrooms,
bathrooms or premises with other products that
take in air for combustion of the same premises
or in premises with an explosive atmosphere. Any
extractor fans, if working in the same environment
or space in which the product is installed, can
cause draft problems.
In Italy, check compatibility pursuant to UNI 10683
and UNI 7129 in the presence of gas products.
The floor must be able to support the weight of the
product and the accessories.
Protection from heat and safe distances
All the surfaces of the building adjacent to the pro-
duct must be protected against heating.The insulation
measurements to implement depend on the type of
surface present.
The product must be installed in accordance with the
following safety instructions:
- minimum distance of 20 cm from flammable materials
along the sides and back.
- no flammable materials may be kept within 80 cm
from the front of the appliance.
Electricity lines
There must be no electricity lines in the
walls or ceiling of the fireplace installation
area.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Edilkamin Windo 2 - 75 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Edilkamin Windo 2 - 75 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.93 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Edilkamin Windo 2 - 75

Edilkamin Windo 2 - 75 Gebruiksaanwijzing en installatiehandleiding - Nederlands - 20 pagina's

Edilkamin Windo 2 - 75 Gebruiksaanwijzing en installatiehandleiding - Deutsch - 20 pagina's

Edilkamin Windo 2 - 75 Gebruiksaanwijzing en installatiehandleiding - Français, Italiano - 40 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info