60
Below is a description of the items
SMOKE TEMP.: Indicates the temperature value read inside the product. To be read only with the guidance of
the Technical Service Centre.
AUGER MOTOR: Indicates the set and read speed. Useful to understand any anomalies of the pellet loading
motor. To be read only with the guidance of the Technical Service Centre.
SMOKE EXTR.: Indicates the set and read speed. Useful to understand any anomalies of the combustion
chamber vacuum motor. To be read only with the guidance of the Technical Service Centre.
LEONARDO: Indicates the set and read target value. To be read only with the guidance of the Technical Service
Centre.
FAN: Indicates the output voltage. To be read only with the guidance of the Technical Service Centre.
IGNITION PLUG (GLOW PLUG): Indicates whether the ignition component is on or off. Useful during ignition to
understand functionality.
HOME AUTOMATION CONTACT: Indicates whether ON or OFF. Useful to understand functionality.
BOILER TEMPERATURE: Indicates the water temperature value read inside the product. It also appears on the
first level display only if the Room Input parameter is set to “No input”. Note that the room temperature will no
longer appear on the display. EACH CASE MUST BE CLARIFIED IN DETAIL WITH THE CUSTOMER. To be
read only with the guidance of the Technical Service Centre.
PWM PUMP: Indicates the primary circuit pump output value (of the kit if optional).
HEATING 3-WAY VALVE: Indicates the functionality of the valve.
SECONDARY PUMP: Indicates whether the pump is ON or OFF.
RELAY AUX: Indicates whether it is OPEN.
REMOTE SIG. PWR: Indicates the signal strength in decibel-milliwatts. Permissible values from 0 to -95 db