78
14.16.1. Parameters
INSTALLER
To adjust some parameters. The probe parameters are active depending on the chosen setup.
Pellet level sensor: Enables or disables the possibility for the end customer to view and select the status of the
pellet reserve light
Airkare mode: To select WHETHER Airkare is active and how big the room is (SMALL, less than 30 m3 or BIG)
or not activate (OFF)
Reset airkare: To reset the working hours of Airkare
Number of fans: Enables or disables the possibility for the end customer to operate the fan, if present.
Room input: To choose which item can be read and adjusted by the customer on the Home display. It depends
on the type of system
Probe: Room probe, standard in the product
No input: Enables the display reading of the water temperature in the boiler. It excludes the heat demand from
the probe or thermostat.
Thermostat: Enables the thermostat, which can be installed instead of the room probe.
Room2/cyl. input: defines the item to be enabled according to the connected component. It depends on the
type of system:
No input (default)
Room probe
Room thermostat
Cylinder probe
Cylinder thermostat
Room3/cyl/se input: Defines the item to be enabled according to the connected component. It depends on the
type of system:
No input (default)
Room probe
Room thermostat
Low cyl probe
Low buff probe
Input puffer: Defines the item to be enabled according to the connected component. It depends on the type of
system:
No input (default)
Probe
Thermostat
Hysteresis DHW: Defines the hysteresis
Buffer hysteresis: Defines the hysteresis
Hyst. buffer : Defines whether or not the water pressure is displayed, via the kit pressure reader.
Pump temp. on: Defines the water temperature for starting the primary pump.
Aux output: Sets the auxiliary output according to system setups:
Remote alarm (default)
Aux boiler
Chrono synch: Synchronises the chrono prog.
Unpair bluetooth: Enables
Enable antifreeze: Enables or disables the antifreeze function
Antifreeze: Sets the temperature for the antifreeze function
Max pump pwm: Defines the maximum pump speed
Climatic k curve: Sets the value for the climatic k curve
Min H2O deliv.C°: Sets the minimum automatic boiler set temperature based on the outside temperature
Max H2O deliv.C°: Sets the maximum automatic boiler set temperature based on the outside temperature