TECHNICAL DATA
Thermal output (burnt) kW 23 29,4 34,5
Power output kW 18 23 27
Overall efficiency % 78,3 78,3 78,3
Efficiency to the water % ~ 70 ~ 70 ~ 70
Optimal wood consumption kg/h 5 6,4 7,5
Total weight including the packaging (min-max) kg 171/189 184/230 251/302
ø female smoke outlet cm 18 20 25
ø stainless steel chimney flue for a height ranging from 3 to 5 m cm 20 25 25
ø stainless steel chimney flue for a height ranging from 5 to 7 m cm 18 22 25
ø stainless steel chimney flue for a height exceeding 7 m cm 18 20 22
ø external air inlet cm 10 10 10
Water capacity litres 60 70 90
Maximum operating pressure bar 1,5 1,5 1,5
Hot sanitary water production (kit 1-3-n3-n3bis-6)
*
l/min
**
10 12 14
Heating capacity
***
m3470 600 705
System return inches 1” 1”¼ 1”¼
System flow inches 1” 1”¼ 1”¼
70
50/50CS 100
A
The fireplace must be installed with an open tank
(EXCEPT FOR IDRO 50/CS).
The water of the radiator circuit warms up, circulates in the
heat exchanger pipe (4) and the hollow space (A) and
skims along the semi-circular wall. The hollow space is
created by using thick steel sheet metal.
4
*boiler temperature is 70°
** (ΔT=25K)
***
Insulation in accordance with the Legislative Decree 192/2005 ex Italian Law 10/91 and subse-
quent changes together with an expected heat output of 35 Kcal/m³ per hour.
IDRO 100
door
IDRO 50
IDRO 50 CS
fixed door
leaf
IDRO 70
fixed door
leafs
IDRO 70
door
IDRO 100
fixed door
leafs
thermal insulation
on the vaulted top
(implemented by the
client)
Specifications
Ø 20
55
18
66
2
64
77 5
65
138
Ø 25
77
80
3138,5
18 55 65,5
99
81
Ø 25
55
18
78
2
81
94
65
138
5
Ø 18
55
18
64
2
64
77 5
65
138
Ø 20
55
18
65
68
3
64
80 8
65,5
138,5
93
105
8
66
68
80