OWNERS MANUAL
How to maintain and operate your
EcoWater digital demand water system
EcoWater Digital Demand
MODELS
ESM11CE
ESM15CE
Ver sion 02 -- 2005
2
ECOWATER
SYST E MS Unpacking
The parts required to assemble and install the unit are included in a parts bag.
Thoroughly check the unit for possible shipping damage and parts loss. Also inspect and note any damage to
the shipping carton.
Remove and discard (RECYCLE) all packing materials. To avoid loss of small parts, we suggest you keep the
small parts in the parts bag until you are ready to use them.
ECOWATER
SYST E MS Table of Contents
Unpacking and Inspection 2
Dimensions/Specifications 3
Wiring Schematic 3
Safety Guides 5
Water Conditioning Information 5
Assembly 7
Planning Installation 8
Installation 11
Programming the Faceplate Timer 16
Customizing Features/Options 18
Routine Maintenance 25
Troubleshooting Guide 27
Repair Parts 30
FOR FUTURE REFERENCE, ENTER THE FOLLOWING INFORMATION
MODEL NO. ¡©
CODE ©
WATER HARDNESS
SERIAL NO. ¡©
INSTALLATION DATE
IRON CONTENT PPM
¡on registration decal ©on shipping carton
3
ECOWATER
SYSTEMS Dimensions / Specifications
IN
OUT
8.6 cm
B
C
A
I N --- O U T
32.4 cm
43.2
cm
MODEL NOMINAL RESIN TANK SIZE A B C
ESM11CE 8” DIA. X 19” 54 cm 41.4 cm 66.8 cm
ESM15CE 8” DIA. X 25” 70 cm 58.4 cm 83.8 cm
Wiring Schematic
24VAC
Transformer
NC
NO
Back of Timer
Green
Position Switch
M
24V
OUT
GND
+5
Turbine
Sensor
4
ECOWATER
SYSTEMS Service Information
MODEL CODE ESM11CE ESM15CE
MODEL CODE E11 E15
FILL CYCLE ¡TIME 1.0---4.0 1.7---9.3
©FLOW 0.3 gpm (1.1 l/min) 0.3 gpm (1.1 l/min)
BRINE CYCLE ¢TIME 64---67 60---77
£FLOW 0.15 gpm (0.57 l/min) 0.15 gpm (0.57 l/min)
BRINE RINSE CYCLE £FLOW 0.10 gpm (0.39 l/min) 0.10 gpm (0.39 l/min)
BACKWASH CYCLE ¤TIME 3 3
£MAX. FLOW 2.2gpm(8.33l/min) 2.2gpm(8.33l/min)
FAST RINSE CYCLE ¤TIME 1 1
£MAX. FLOW 2.2gpm(8.33l/min) 2.2gpm(8.33l/min)
¡minutes, varies with capacity operating level
©gallon or liters per minute flow to brine tank
¢includes brine rinse cycle minutes
£gallon or liters per minute flow to drain
¤factory set default minutes
Values listed are certified by WQA ESM11CE ESM15CE
Rated Softening Capacity
_Fm#@kgofSalt
30 @ 0.4
49 @ 0.9
65 @ 1.6
48 @ 0.7
80 @ 1.4
113 @ 3.8
Rated Service Flow Rate (l/ min) 15 23
Amount of High Capacity Resin (Liters) 10.5 15
Pressure Drop at Rated Service Flow (Bar) 0.3 0.6
Peak flow @ 1 bar pressure drop (l/min) 32.8 31.7
Water Supply Max. Clear Water Iron (ppm) 0 4
Water Pressure Limits (min./max. bar) 1.4 to 8.6 1.4 to 8.6
Min. --- Max. Water Temperature (˚C) 4 --- 4 9 4 --- 4 9
Min. Water Supply Flow Rate for a regeneration (litres/min) 11 11
Max. Drain Flow Rate (litres/min) 8.33 8.33
Valve conections 3/4” 3/4”
Electrical rating 24 VAC / 50 Hz 24 VAC / 50 Hz
ESM11CE ESM15CE
Salt Storage Capacities 25 50
5
ECOWATER
SYST E MS Safety Guides
Follow the installation instructions carefully. (Failure to install the unit properly voids the warranty.)
Before you begin installation, read this entire manual. Then, obtain all the materials and tools you will need to
make the installation.
Check local plumbing and electrical codes. The installation must conform to them.
Use only lead--free solder and flux for all sweat-solder connections, as required by local codes.
Use care when handling the unit. Do not turn upside down, drop, or set on sharp protrusions.
Do not locate the unit where freezing temperatures occur. Do not attempt to treat water over 49_C. Freezing, or
hot water damage voids the warranty.
Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non--metallic parts.
The unit requires a minimum water flow of 11 litres per minute at the inlet. Maximum allowable inlet water
pressure is 8.6 bar. If daytime pressure is over 5.5 bar, nighttime pressure may exceed the maximum. Use a
pressure reducing valve if necessary. (Adding a pressure reducing valve may reduce the flow.)
The unit works on 24 volt--50 hz electrical power only. Be sure to use the included transformer.
This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
ECOWATER
SYST E MS Water, and Water Conditioning
Water Conditioning
Water conditioning is the treatment of four general conditions. These are:
1. HARDNESS
2. IRON
3. ACIDITY
4. SEDIMENTS
1. HARDNESS is a term to describe the presence of calcium and magnesium minerals in water. A chemical
analysis accurately measures the amount of minerals in grain weight. For example, one gallon@of water with
5 grains per gallon (gpg)!hardness has dissolved minerals, that if solidified, about equals the size of one
ordinary aspirin tablet. One gallon@of water, 25 gpg!hard, has a mineral content equal in size to 5 aspirin
tablets. Water hardness varies greatly across the country. It generally contains from 3 to 100 gpg!.
Hard water affects living in general. Hardness minerals combine with soap to make a soap curd. The curd
greatly reduces the cleaning action of soap. Precipitated hardness minerals form a crust on cooking utensils,
appliances, and plumbing fixtures. Even the tastes of foods are affected. A water softener removes the
hardness minerals to eliminate these problems, and others.
!1 gpg = 0.959 _d = 1.71 _F
@1 gallon = 3.78 litres.
Sodium Information: Water softeners using sodium chloride (salt) for regeneration add sodium to the water.
Persons on sodium restricted diets should consider the added sodium as part of their overall intake.
6
ECOWATER
SYST E MS Water, and Water Conditioning
2. IRON in water is measured in parts per million (ppm). The total* ppm of iron, and type or types*, is determined
by chemical analysis. Four different types of iron in water are:
¡Ferrous (clear water),
©Ferric (red water),
¢Bacterial and organically bound iron,
£Colloidal and inorganically bound iron (ferrous or ferric).
*Water may contain one or more of the four types of iron and any combination of these. Total iron is the sum
of the contents.
¡Ferrous(clearwater)iron issoluble anddissolves inwater. It is usuallydetected bytaking a sample ofwater
in a clear bottle or glass. Immediately after taking, the sample is clear. As the water sample stands, it gradually
clouds and turns slightly yellow or brown as air oxidizes the iron. This usually occurs in 15 to 30 minutes. This
unit will remove moderate amounts of this type of iron (see specifications).
When using the softener to remove Ferrous (clear water) iron, add 5 grains!to the hardness setting
for every 1 ppm of Ferrous (clear water) iron. !1 gpg = 0.959 _d = 1.71 _F
©Ferric (red water), and ¢Bacterial and organically bound irons are insoluble. This iron is visible
immediatelywhen drawn from a faucet because it hasoxidized beforereaching thehome. Itappears assmall
cloudyyellow, orange, orreddish suspended particles. After the water stands for a period of time, the particles
settle to the bottom of the container. Generally these irons are removed from water by filtration. Chlorination
is also recommended for bacterial iron. This unit will not remove ferric or bacterial iron.
£Colloidal and inorganically bound iron is of ferric or ferrous formthat will not filter or exchange out of water.
In some instances, treatment may improve colloidal iron water, but always CONSULT A QUALIFIED WATER
CHEMISTRY LAB before attempting to treat it. Colloidal iron water usually has a yellow appearance when
drawn. After standing forseveralhours, the colorpersists and the iron does not settle, but remains suspended
in the water.
Iron in water causes stains on clothing and plumbing fixtures. It negatively affects the taste of food, drinking
water, and other beverages. This unit will not remove colloidal iron.
3. ACIDITY or acid water is caused by carbon dioxide, hydrogen sulfide, and sometimes industrial wastes. It is
corrosive to plumbing, plumbing fixtures, water heaters, and other water using appliances. In can also
damage and cause premature failure of seals, diaphragms, etc., in water handling equipment.
A chemical analysis is needed to measure the degree of acidity in water. This is called the pH of water. Water
testing below 6.9 pH is acidic. The lower the pH reading, the greater the acidity. A neutralizer filter or a
chemical feed pump are usually recommended to treat acid water.
4. SEDIMENT is fine, foreign material particles suspended in water. This material is most often clay or silt.
Extreme amounts of sediment may give the water a cloudy appearance. A sediment filter installed ahead
of the water softener normally corrects this situation.
7
ECOWATER
SYST E MS Assembly
1. Water softeners are factory assembled. During installation, remove the Salt Hole Cover. Set aside to prevent
damage. Check the brinewell to be sure it is secured and vertical (see Figure 1). Slide Faceplate Cover
forward to expose back valve assembly.
2. Lift the brine valve out of the brinewell. Be sure the float stem isparallel to stand tube so sealswillseat properly
during operation. Replace the brine valve in the brinewell bottom and install the Brinewell Cover.
3. Install the brine tank overflow grommet and elbow in the 2 cm diameter hole in the back of the salt storage
tank sidewall.
Grommet
Elbow
Nozzle Assembly
Brine Tubing
Salt
Storage
Tank
Brinewell
Brine Valve
Brinewell
Cover
Float Stem
Faceplate Cover
Salt Hole Cover
Figure 1
8
ECOWATER
SYST E MS Planning Installation
Inlet -- Outlet Plumbing Options
ALWAYS INSTALL either a single bypass valve (not included) or a 3 valve bypass system (not included).
Bypass valves allow you to turn off water to the softener for repairs if needed, but still have water in house
pipes.
Use 3/4” (minimum) pipe and fittings.
Use sweat copper... or, threaded pipe... or, PVC plastic pipe... or, other approved plumbing.
NOTE: Salt Hole and Faceplate cover not
shown for clarity of drawing.
Tieorwirevalvedrainhoseinplace,to
keep over floor drain.
Hard
Water
Conditioned
Water
Floor Drain
Salt Storage Tank
Overflow Hose
4cmAirgap
INLET
OUTLET
Valve Drain Hose
Transformer
To Timer
NOTE: Air gap requirements on Fig. 2.
3/4” pipe and fittings
To O u t si d e
Facets
inlet valve
outlet valve
bypass valve
Figure 2
9
ECOWATER
SYST E MS Planning Installation
Other Requirements
A 220V--50Hz, grounded electrical outlet (continuously ‘live’’) is needed within 2 meters of the unit.
A drain isneeded for regeneration discharge water. A floor drain, close to the unit, is preferred. A laundry tub,
standpipe, etc., are other drain options.
STANDPIPE
4cm
Airgap
Drain
Hose
4cm
Airgap
Drain
Hose
LAUNDRY TUB
Figure 3
Tools and Materials You May Need
Common Screwdriver Tape Measure
Pliers Pipe and fittings as required
Soldered Copper
Tubing cutter LEAD--FREE solder and flux
Propane torch Emery cloth, sandpaper or steel wool
Misc. fittings
Threaded
Pipe cutter or hacksaw Pipe joint compound
Threading tool Misc. fittings
CPVC Plastic
Pipe cutter Solvent cement
Hacksaw Primer
Adjustable wrench Misc. fittings
NOTE: The salt storage tank drain elbow accepts either 1/2” or 3/8” I. D. hose.
VALVE DRAIN OPTIONS: Flexible drain hose is not allowed in all localities (check your plumbing codes). For a
rigid valve drain run, cut the barbed section off the drain fitting for access to the 1/4” pipe threads. Then plumb
a rigid drain as needed (see Figure 4).
10
ECOWATER
SYST E MS Planning Installation
1/4” NPT
Barbs for 3/8 I.D. tubing
#7024160
1/4” NPT Threads
Barbs
1/2” Outside Diameter Copper
Tube (Not Furnished)
Clip
Cut Barbs from Drain Fitting (Pull
Clip and Remove Fitting From
Valve)
Comp Fitting 1/4 NPT x 1/2” O.D. Tube
(Not Furnished)
Figure 4
Select Installation Location
Consider all of the following when selecting an installation location for the unit.
To condition all water in the home, install the unit close to the water supply inlet,and before all other plumbing
connections, EXCEPT outside water pipes. Outside faucets should remain on hard water to avoid wasting
conditioned water and salt.
A nearby drain is needed to carry away regeneration discharge water. Use a floor drain, laundry tub, sump,
standpipe, etc., or other options (check your local codes).
The unit works on 24 volts only. A transformeris required to reduce220V--50 Hzhousehold electricalpower.
Provide an approved, grounded outlet within 2 meters of the unit.
Always install the unit BEFORE the water heater and afterall otherinstalled water conditioning equipment
(see Figure 5 below).
Water
Softener
Pressure
Tank
Well
Pump
Well Water
Supply
Cold to
Water Heater
Optional
Sediment
Filter
Water from
Municipal Supply
Private Well Only
Figure 5
11
ECOWATER
SYST E MS Planning Installation
Optional Weather Protection
If installing the unit in an outside location, be sure to provide protection from the elements, contamination,
vandalism, and direct sunlight.
An optional Weather Cover is available for outdoor installations by contacting your local dealer.
Attaches to back of
Faceplate Cover
Figure 6
ECOWATER
SYST E MS Installation
Step 1. Turn Off Water Supply
1. Close the main water supply valve, near the well pump or water meter.
2. Shut off the electric or fuel supply to the water heater.
3. Open all faucets to drain all water from the house pipes.
Step 2. Move the Unit into Place
Move the unit into installation position. Set it on a solid, smooth and level surface. If needed, place the unit on
a section of plywood, a minimum of 2 cm thick. Then, shim under the plywood to level the unit, see Figure 7.
CAUTION: DO NOT PLACE SHIMS DIRECTLY UNDER THE SALT STORAGE TANK. The weight of the tank,
when full of water and salt, may cause the tank to fracture at the shim.
Shim Plywood
Figure 7
12
ECOWATER
SYST E MS Installation
Visually check and remove any foreign materials from the valve inlet and outlet ports.
If not already done, put a light coating of silicone grease or Vaseline on the bypass valve o-rings.
Push the bypass valve into the softener valve as far as it will go. Snap the two large holding clips into place,
from the top down as shown in Figure 8.
CAUTION: Be sure the clips snap firmly into place so the bypass valve will not pull out.
Side View End View
O --- r i n g S e a l
Valve Body In-
let or Outlet
Bypass Valve (Push all
the way in)
Clips
Figure 8
Step 3. Assemble Inlet and Outlet Plumbing
Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of the
valve.
Be sure hard water supply pipe goes to the valve inlet side.
NOTE: Inlet and outlet are marked on the valve. Trace the water flow direction to be sure.
CAUTION: Be sure to fit, align and support all plumbing to prevent putting stress on the softener valve inlet
and outlet. Undo stress may cause damage to the valve.
Step 4. Connect Inlet and Outlet Plumbing
Complete the inlet and outlet plumbing as applicable, below.
1. SOLDERED COPPER
a. Thoroughly clean and flux all joints.
b. Make all solder connections. Be sure to keep fittings fully together, and pipes square and straight. DO NOT
solder with installation tubes attached to bypass valve. Soldering heat will damage the valve.
2. THREADED PIPE
a. Apply pipe joint compound to all outside pipe threads.
b. Tighten all threaded joints.
c. If soldering to the inlet and outlet tubes, observe step 1above.
3. CPVC PLASTIC PIPE
a. Clean, prime and cement alljoints, following the manufacturer’s instructions supplied with the plastic pipe and
fittings.
b. If soldering to the inlet and outlet tubes, observe Soldered Copper step 1above.
13
ECOWATER
SYST E MS Installation
Step 5. Cold Water Pipe Grounding
WARNING: The house cold water pipe (metal only) is often used as a ground for the house electrical system.
The 3-valve bypass type of installation, shown in Figure 2, will maintain ground continuity. If you
use a plasticbypass valve at the unit, continuity is broken. To restore the ground, do the following.
Install a #4 copper wire across the removed section of main water pipe, securely clamping at both ends, see
Figure 9 (parts not included).
NOTE: Check local plumbing and electrical codes for proper installation of the ground wire.
Ground Wire
Clamp (2)
Figure 9
Step 6. Install Valve Drain Hose
NOTE: See valve drain options on page 9.
1. Connecta length of 3/8” or7/16” I.D. hose (check codes) to the valve drain elbow, on the controller, see Figure
4. Use a hose clamp to hold the hose in place. Route the hose out through the notch in the Faceplate Cover.
2. Run the hose to the floor drain, and as typically shown in Figure 2, tie orwire the end to a brick or otherheavy
object. This will prevent ‘‘whipping’’ during regenerations. Be sure to provide a 4 cm minimum air gap, to
prevent possible sewer water backup.
NOTE: In addition to a floor drain, you can use a laundry tub, or standpipe as a good drain point for thishose.
Avoid long drain hose runs, or elevating the hose more than 2.5 meters above the floor.
Step 7. Install Salt Storage Tank Overflow Hose
1. Connect a length of 3/8” I. D. hose to the salt storage tank overflow elbow and secure in place with a hose
clamp(seeFigure2).
2. Runthe hose to the floor drain, orothersuitable drain point no higher thanthe drain fitting onthe saltstorage
tank. (This is a gravity drain.) If the tank overfills with water, the excess water flows to the drain point.
NOTE: Route the tubing neatly out of the way and cut it to the desired length.
DO NOT connect the valve drain tubing from step 6 to the salt storage tank over flow hose.
14
ECOWATER
SYST E MS Installation
Step 8. Pressure Testing for Leaks
To prevent excessive air pressure in the unit and plumbing system, do the following steps EXACTLY in
order.
1. Fully open two or more softened cold water faucets nearby the unit.
2. Place the bypass valve(s) in “bypass” position. See Figure 10.
3 --- V a l v e B y p a s s
Outlet
Valve
Inlet
Valve
Bypass
Valve
To
Conditioner
From
Conditioner
Single Valve Bypass
3 --- Va l v e B y p a s s
for SERVICE:
Open the inlet and
outlet valves.
Close the bypass
valve.
for BYPASS:
Close the inlet and
outlet valves.
Open the bypass
valve.
PUSH IN
for Bypass
PULL OUT
for Service
Figure 10
3. Fully open the main water supply valve. Observe steady flow from the opened faucets, with no air bubbles.
4. EXACTLY as follows, place bypass valve(s) in “service”.
a. SINGLE BYPASS VALVE: SLOWLY, move the valve stem toward “service”, pausing several times to allow
the unit to pressurize slowly.
b. 3--VALVE BYPASS: Fully close the bypass valve and open the outlet valve. SLOWLY, open the inlet valve,
pausing several times to allow the unit to pressurize slowly.
5. After about three minutes, open a hot water faucet for about one minute, or until all air is expelled, then
close.
6. Close all cold water faucets and check your plumbing work for leaks.
Step 9. Add Water and Salt to the Salt Storage Tank
1. Using a container, add about 4 litres of clean water into the salt storage tank.
2. Fill the salt storage tank with salt.
NOTE: See page 25 for additional information on salt.
Step 10. Sanitizing the Softener
Care is taken at the factory to keep your unit clean and sanitary. Materials used to make the unit will not infect
or contaminate your water supply, and will not cause bacteria to form or grow. However, during shipping, storage,
installing and operating, bacteria could get into the unit. For this reason, sanitizing as follows is suggested 1when
installing.
1Recommended by the Water Quality Association. On some water supplies, the unit may need periodic disinfecting.
1. Remove the Brinewell Cover and pour about 45 ml. (2 to 3 tablespoons) of common household bleach into
the softener brinewell, Figure 1, page 7. Clorox, Linco, BoPeep, White Sail, Eagle, etc. are brand names
of bleach readily available. Replace the Brinewell Cover.
2. The final step in the sanitizing procedure is done as you complete the following steps, including timer
programming on page 16.
15
ECOWATER
SYST E MS Installation
3. This process will flush out all sanitizing solution and condition the unit.
Step 11. Connect Transformer
1. Connect the power cable leads to the two terminals on the transformer.
NOTE: Check to be sure all leadwire connectors are secure on the back of the timer.
CAUTION: Be sure allwiring is away from the valve gear and motorarea, which rotates during regenerations.
2. Plugthe transformerinto acontinuously live”,grounded houseelectricaloutlet,approved bylocalcodes.THE
UNIT WORKS ON 24V ONLY. DO NOT CONNECT WITHOUT THE TRANSFORMER.
Transformer
Position Switch
Valve
Motor
Back of Timer
Turbine Sensor
Figure 11
Step 12. Start a Recharge
Press the RECHARGE button and hold for three seconds untilRecharge Nowbegins to flash inthe timer display,
starting a recharge. This recharge draws the sanitizing bleach into and through the unit. Any air remaining in the
unit is purged to the drain.
Step 13. Restart the Water Heater
Turn on the electricity or fuel supply to the water heater, and light the pilot, if applicable.
NOTE: The water heater is filled with HARD water and, as hot water is used, it refills with conditioned water.
In a few days, the hot water will be fully conditioned. To have fully conditioned hot water immediately,
wait until the recharge (Step 12) is over. Then, drain the water heater until water runs cold.
Step 14. Install the Salt Hole and Faceplate Cover(s).
Complete the Programming Steps on pages 16 -- 17.
16
ECOWATER
SYSTEMS Programming the Digital Demand Faceplate Controller
UP Keypad
DOWN Keypad
SELECT/EXIT Keypad
RECHARGE Keypad Display
Digital Demand
RECHARGE
SALT
LEVEL
SALT LEVEL Keypad
Figure 12
THE FOLLOWING STEPS ARE FOR FIRST TIME SET UP ONLY.
When the transformer is plugged in, a ‘beep’ will sound, followed by the factory set model code display and soft-
ware version for a few seconds. Then, 12:00 PM present time display.
1. MODEL CODE: The controller is factory set to the model code, which provides the shortest recharge times
and greatest water savings. Verify the correct model code or set if needed.
Note: To reset the model code, see page 24.
2. SET THE CLOCK:Use the ()or() keypads to set the present time of day. Press () to move the display
ahead; press () to move the time backward. NOTE:Each pressof a keypadchanges thetime by1 minute.Hold-
ing a keypad in changes the time by 32 minutes each second. Pressing the SELECT/EXIT () keypad will set
the clock.
17
ECOWATER
SYSTEMS Programming the Digital Demand Faceplate Controller
3. SET WATER HARDNESS:The controller is factory set to 430 ppm (25 gpg)!. Set the ppm(gpg)!hardness
of your water supply. Water hardness is determined by water analysis, or call your local water department. Use
the ()keypad to advance the number; use the () keypad to reduce thenumber. Eachpress ofa keypadchanges
the display by 10 (or in gpg mode by 1). Hold down the keypad to scroll. After 400 ppm (25 gpg), scrolling will
be at a faster rate. NOTE: To compensate for iron in the water, add 86 ppm(5gpg) to the hardness number for
each 1 ppmof iron.Pressing theSELECT/EXIT () keypad will set the hardnesslevel. NOTE: If usingpotassium
chloride (KCl) instead ofstandard sodium chloride (NaCl)water softenersalt, hardness settingmust beincreased
by 25%.
!1 gpg = 0.595 _d = 1.71 _F = 17.1 PPM
4. SET RECHARGE (REGENERATION) TIME: The controller is factory set to 2:00 AM. At this setting, the
EcoWater conditioner begins recharge, or regeneration, ending no later than 5:30 AM. This is a good time in most
households because water is not being used. If hot water is used while the unit is regenerating, the water heater
will refill with hard water. To select a different recharge start time, use the ()or() keypad. Pressing the SELECT/
EXIT ( ) keypad will set the recharge time.
5. Press the RECHARGE keypad to get to the recharge menu. Move the cursor to Start Recharge Now and press
the SELECT/EXIT ( ), starting a recharge. This recharge draws the bleach (see step 12, page 15) through
the EcoWater conditioner to sanitize it and to purge any air remaining in the resin tank assembly.
6. RESTART THE WATER HEATER: Turn on the electric or fuel supply to the water heater, and light the
pilot, if applies.
NOTE: The water heater is filled with HARD water and, as hot water is used, it refills with conditioned water.
In a few days, the hot water will be fully conditioned. To have fully conditioned hot water immediately, wait
until the recharge (step 6) is over. Then, drain the water heater until water runs cold.
INSTALLATION OF THE DIGITAL DEMAND ECOWATER CONDITIONER IS COMPLETE.
Additional faceplate controller features and options are described on following pages.
18
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
NORMAL SCREEN VIEWS
The display will scroll through as many as 5 screens at an interval of 4 seconds
each.
FSoft Water Available will show a percent of available soft water and a bargraph
at the bottom of the display.
FWater Flow Rate shows litres per minute or gallons per minute (GPM) flowing
through the system at that time and a moving bar graph at the bottom of the
screen.
FRecharge Tonight is shown only if the unit will be initiating a recharge that
night.
FSalt Level is Low is shown only if the salt level is below the amount set for
warning.
FIf the unit is in recharge, the display will show remaining time in recharge and
current stage of recharge.
PROGRAM MEMORY: If electrical power to the EcoWater conditioner goes off, the display isblank, but the face-
plate controller keeps the correct time for at least two days. When electrical power comes on again, you have to
verify clock time iscorrect.The MODEL CODE, HARDNESS and RECHARGE TIME never need resettingunless
a change is desired.
Even if the controller is incorrect, after a long power outage, the unit works as it should to keep your water condi-
tioned. However, regenerations may occur at the wrong time of day until you reset the controller to the correct
time of day. To reset present time, see step 2 on page 16.
CONTROL FEATURES:There are two keypads on the left side of the display. Salt Level
keypad is used when adding salt to the brine tank. The level number on the brinewell corre-
sponds to the number toprograminto the controller. Recharge keypad hastwo options: Set/
Cancel recharge tonight, which either sets or cancels a recharge for that night and Start Re-
charge Now, which will start a recharge immediately. NOTE: If in a recharge, and the
Recharge keypad is pressed, it will advance the valve to the next regeneration cycle.
DSOUND ‘BEEPER’-- A ‘beeper’ sounds while pressing keypads for controller setup. One beep signals a
change in the faceplate display. Repeated beeps means the controller will not accept a change from the keypad
you have pressed, telling you to use another keypad. Forexample,while settingthe hardnessnumber, the beeper
sounds repeatedly when the display reaches 1 using the () keypad or 160, for example, using the () keypad.
SALT LEVEL: This feature is used when salt is added to the conditioner. Press the salt level keypad and use
the () keypad to reset the level of salt as it corresponds to the decal on the brinewell. Press the SELECT/EXIT
() to set and return to Normal Screen Views.
19
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
INITIATING EXTRA RECHARGES
RECHARGE NOW: Press the Recharge keypad to go to the recharge menu. Move square cursor down to Start
Recharge Now. Press SELECT/EXIT keypad and a recharge begins immediately.
To assure an adequate supply of conditioned water, at times of unusual or unexpected high water use demand,
use the RECHARGE NOW feature. For example, if you have guests and the Soft Water Available screen is at
or below 50%, you could deplete conditioned water capacity before the next recharge is automatically initiated.
To be sure this will not happen, use RECHARGE NOW to restore 100% conditioned water capacity.
RECHARGE TONIGHT: Press the Recharge keypad to go to the recharge menu. Move cursor down to Set/Can-
cel Recharge Tonight. Press SELECT/EXIT keypad to return to Normal Screen Views. When this feature is set,
the EcoWater conditioner will regenerate at the next programmed start time. This feature is beneficial to assure
a sufficient supply of conditioned water for an expected heavy water usage the next day.
To cancel a recharge when RECHARGE TONIGHT is shown, press the Recharge keypad to go to the recharge
menu. Move cursor down to Set/Cancel Recharge Tonight. Press SELECT/EXIT keypad to return to Normal
Screen Views.
The following is a description of the options in the Primary Menu. To enter this menu press SELECT/EXIT ()
keypad and move square cursor (J) to menu choice. To exit to Normal Screen Views move square cursor (J)
to EXIT, which appears at either the top or the bottom of this menu. If no keypad has been pressed display will
show for 4 minutes before defaulting back to the Normal Screen Views.
SetClock:Enter PrimaryMenu. Press the ()or() keypads untilcursor is next
to Set Clock. Again, use the ()or() keypads to set the present time of day,
being sure AM or PM shows, as applicable. Press () to move the display
ahead; press () to move the time backward. NOTE: Each press of a keypad
changes the time by 1 minute. Holding a keypad in changes the time by 32 min-
utes each second. Press the SELECT/EXIT ( ) keypad to set.
Set Water Hardness:Enter Primary Menu. Press the ()or() keypads until
cursor is next to Set Hardness. Press the SELECT/EXIT ( ) keypad once to
display a flashing number and ppm (or GRAINS). Set the ppm!hardness of
your water supply. Use the () keypad to advance the number; use the ()key-
pad to reduce the number. Pressing the SELECT/EXIT ( ) keypad will set the
hardness level. NOTE: If using potassium chloride (KCl) instead of standard
sodiumchloride (NaCl)water softener salt, hardness settingmust beincreased
by 25%. !1gpg = 0.959 _d = 1.71 _F = 17.1 ppm
Set Recharge (Regeneration) Time: Enter Primary Menu.Press the ()or()
keypads until cursoris next to Set Recharge Time. Pressthe SELECT/EXIT()
keypad once to display a flashing 2:00 AM. At this setting, the EcoWatercondi-
tioner begins recharge, or regeneration, at 2:00 AM., ending no later than 5:30
AM. This is a good time in most households because water is not being used.
If hot waterisused while the unit is regenerating, the water heater will refill with
hard water. To select a different recharge start time, use the ()or() keypad.
Pressing the SELECT/EXIT ( ) keypad will set the recharge time.
continued
20
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
Primary Menu, continued
Water Flow Rate: Enter Primary Menu. Press the ()or() keypads until cursor
is next to Water Flow Rate. Press the SELECT/EXIT () keypad. When se-
lected, this screen will show the water flow rate in liters per minute (LPM) or gal-
lons per minute (GPM) with the moving bar graph at the bottom of the display.
Water Used Today: Enter Primary Menu. Press the ()or() keypads until cur-
sor is next to Water Used Today. Press the SELECT/EXIT () keypad and the
liters/gallons used since midnight will be shown in the display.
Average Water Use: EnterPrimaryMenu. Pressthe ()or() keypads untilcur-
sor is next to Average Water Use. Press the SELECT/EXIT () keypad and the
average liters/gallons use each day will be shown in the display.
Soft Water Meter: Enter Primary Menu. Pressthe ()or() keypads untilcursor
is next to Soft Water Meter. Press the SELECT/EXIT () keypad. This screen
issimilartoatripodometerinthat itwill count the numberof liters/gallonsthrough
the system until it is reset. To reset back to zero press the () keypad.
Set Rolling Screen: Enter Primary Menu. Press the ()or() keypads until cur-
sor is next to Set Rolling Screen. Press the SELECT/EXIT () keypad. This
menu will disable the Normal Screen Views from scrolling and will show only the
screen that is most current.
Set 12/24 Hour Clock: Enter Primary Menu. Press the ()or() keypads until
cursor is next to Set 12/24 Hour Clock. Press the SELECT/EXIT ( ) keypad.
Moving the ()or() keypads will change clock display from 12 hour (AM & PM)
or 24 hour format.
Set Gallons/Liters: Enter Primary Menu. Press the ()or() keypads until cur-
sor is next to Set Gallons/Liters. Press the SELECT/EXIT () keypad. Moving
the ()or() keypads will change displays to indicate water in gallons or liters.
Set Grains/PPM: Enter Primary Menu. Press the ()or() keypads until cursor
is next to Set Grains/PPM. Press the SELECT/EXIT () keypad. Change be-
tween diplaying hardness units in grains or parts per million (PPM). Note: 1 gpg
= 0.959 _d = 1.71 _F = 17.1 ppm
continued
21
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
Primary Menu, continued
Send E.A.S.E. Message: Enter Primary Menu. Press the ()or()key-
pads until cursor is next to Send E.A.S.E. Message. Press the SELECT/
EXIT ( ) keypad. The unit will automatically start sending E.A.S.E.mes-
sage and show a progress bar on the display.
Advanced/Service: By entering these menus, a warning screen will first
be displayed. Only technicians or knowledgeable users should use these
menus.
22
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
The following is a description of the options in the Advanced/Service Menu. To enter any of the following menus,
pressSELECT/EXIT() to enterPrimary Menu. Pressthe ()or() keypads until cursor is next to Advanced/Ser-
vice. Press the SELECT/EXIT ( ) keypad to enter this menu. Warning screen will show, press the () keypad
to continue. To exit to Normal Screen Views move square cursor (J) to EXIT, which appears at either the top or
the bottom of this menu. If no keypad has been pressed display will show for 4 minutes before defaulting back
to the Normal Screen Views.
Set Language: Press the ()or() keypads until cursoris next to Set Language.
Language can be changed from English to Spanish or French. Warning: If the
language has been mistakenly changed, the following steps can be followed to
reset.
1) Unplug transformer, then reapply power to the unit. After 4 seconds, the time
of day should show in the upperright corner. If the time of day is not shown, press
the SELECT/EXIT ( ) keypad until it is.
2) Press the SELECT/EXIT ( ) keypad.
3) Press the ()keypad untilthe square cursor(J) is next to one of the following:
Advanced/Service (English)
Servicio/Avanzando (Spanish)
Fonct avanc (French)
4) Press the SELECT/EXIT ( ) keypad.
5) Press the () keypad.
6) Press the ()keypad untilthe square cursor(J) is next to one of the following:
Set Language (English)
Seleccionar idioma (Spanish)
Réglage langue (French)
7) Press the SELECT/EXIT ( ) keypad.
8) Language can now be selected bypressing the ()or() keypads until the cur-
sor is next to correct language.
9) Press the SELECT/EXIT ( ) keypad to select language.
10) Press the ()or() keypads until cursor is next to EXIT.
11) Press the SELECT/EXIT ( ) keypad.
Diagnostics: Press the ()or() keypads until cursor is next to Diagnostics and
press SELECT/EXIT ( ). This screen is for viewing only and will show any error
codes plus information about the unit. Use the ()or() keypads to view all lines
of the screen. See page 28.
Set Low Salt Alert: Press the ()or() keypads until cursor is next to Set Low
Salt Alert and press SELECT/EXIT ( ). Use the ()or() keypads to change
Alert Level. At this level the controller will signal that salt needs to be added to
the conditioner brine tank. Press SELECT/EXIT ()toexit.
continued
23
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
Advanced/Service Menu, continued
Efficiency Mode: Press the ()or() keypads until cursor is next to Efficiency
Mode and press SELECT/EXIT ( ). Default is Auto Adjusting which has a
minimum efficiency of 3350 grains/lb of salt ( = 48.2 _Fm#/kg of salt). Use the ()
or () keypads to change to either High Capacity which sets the regeneration
salt doses that are increased by a certain % to handle applications requiring 1.5
PPM (parts per million) or less soft water, or to handle special cases such as low
leakage requirement or problemwater conditions; and SaltEfficient which oper-
ates at a minimum of 4000 grains/lb of salt (= 57.5 _Fm#/kg of salt) . Changing
this setting will prompt a warning that changes could affect performance. Press
SELECT/EXIT ()toexit.
Set Max Days/Recharge: Press the ()or() keypads untilcursor is next to Set
Max Days/Recharge and press SELECT/EXIT ( ). Default is Automatic. The
algorithm will determine when to recharge. Use the ()or() keypads to change
between 1 and 15 days. With this setting the unit will never go past number of
days set for a recharge, but could recharge before. Press SELECT/EXIT ()to
exit.
Set 97% Feature: Press the ()or() keypads until cursor is next to Set 97%
Feature and press SELECT/EXIT ( ).DefaultisOff.Usethe() keypad to set
to On. By setting to On, unit will automatically recharge when 97% capacity has
been used, at any time of day. Press SELECT/EXIT ()toexit.
SetBackwashTime:Pressthe()or() keypadsuntilcursoris next to SetBack-
wash Time and press SELECT/EXIT ( ). Time can be changed from 1 to 30
minutes. See chart on page 4 for recommended backwash time. Press SE-
LECT/EXIT ()toexit.
Set 2nd Backwash: Press the ()or() keypads until cursor is next to Set 2nd
Backwash and press SELECT/EXIT ( ). Default is Off. Use the () keypad to
set to On. When set to On, unit will always perform a 2nd backwash and rinse.
Press SELECT/EXIT () to exit. Elect this feature if water contains a lot of sedi-
ment or iron.
SetFastRinse:Press the ()or() keypads untilcursorisnext to Set FastRinse
and press SELECT/EXIT (). Time can be changed from 1 to 30 minutes. See
chart on page 4 for recommended fast rinse time. Press SELECT/EXIT ()to
exit.
continued
24
ECOWATER
SYSTEMS Faceplate Controller, Features/Options
Advanced/Service Menu, continued
Set Model: The controller is factory set to the model code, which provides the
shortest recharge times and greatest water savings. Do the following to change
to this code, if desired.
1) Press the ()or() keypads until cursor is next to Set Model and press SE-
LECT/EXIT (). Warning screen will display, press () to continue.
2) Use the ()or() keypads to change to new model code. Be sure to set the
correct code, or the EcoWater conditioner will operate on incorrect timing.
NOTE: If this feature is changed, it will delete all information stored in the control-
ler (Hardness, Recharge time will have to be reset. All usage history will be
cleared). When you are certain the correct code appears, press SELECT/EXIT
() to exit. Warning screen will appear after changing model code, press ()to
continue. The display will return to the start--up screens.
MODEL NUMBER
(on rating decal) Required Code
ESM11CE E11
ESM15CE E15
Restore To Factory Settings: Press the ()or() keypads until cursor is next
to Restore System and press SELECT/EXIT (). Default is No. If set to Yes will
restore controller to factory settings. NOTE: This will affect ALL settings, and
controller will go through first time set--up screens again. Press SELECT/EXIT
()toexit.
NOTE: ALSO SEE SERVICE INFORMATION, PAGES 28 THROUGH 29.
25
ECOWATER
SYST E MS Routine Maintenance
Refilling With Salt
Remove the Salt Storage Tank Front Cover and check the salt storage level frequently. If the conditioner uses
all the salt before you refill it, you will get hard water. Until you have established a refilling routine, check the salt
every two or three weeks. ALWAYS refill if less than 1/3 full. Be sure the Brinewell Cover is on.
NOTE: In humid areas, it is best to keep the salt storage level lower, and to refill more often.
RECOMMENDED SALT: Cube,pellet, coarse solar, etc., water conditionersalt isrecommended. Thistype ofsalt
is from high purity evaporated crystals, sometimes formed, or compressed, into briquets. It has less than 1%
insoluble (will not dissolve in water) impurities.
SALT NOT RECOMMENDED: Rock salt, high in impurities, block, granulated, table, ice melting, ice cream
making salts, etc., are not recommended.
SALT WITH IRON REMOVING ADDITIVES: Some salts have an additive to help a water conditioner handle iron
in a water supply.
Breaking A Salt Bridge
Sometimes, a hard crust or salt bridge forms in the brine tank. It is usually caused by high humidity or the wrong
kind of salt. When the salt bridges, an empty space forms between the water and the salt. Then, salt will not
dissolve in the water to make brine. Without brine, the resin bed does notregenerate and you will have hard water.
If the storage tank is fullof salt, it ishard to tellif you have a salt bridge. Salt isloose on top,but thebridge isunder
it. Take a broom handle, or like tool, and push it straight down into the salt. If a hard object is felt, it’s most likely
a salt bridge. Carefully push into the bridge in several places to break it. DO NOT use any sharp or pointed
objects as you may puncture the tank.
Broom
Handle
Push Tool into Salt
Bridge to Break
Salt
Salt Bridge
Water Level
Pencil
Mark
2---5
cm
Figure 13
26
ECOWATER
SYST E MS Routine Maintenance
Cleaning the Nozzle and Venturi
A clean nozzle and venturi (see Figure 14) is a must for the conditioner to work properly. This small unit creates
the suction to move brine from the brine tank, into the resin tank. If it should become plugged with sand, silt, dirt,
etc., the conditioner will not work, and you will get hard water.
To get to the nozzle and venturi,slide Faceplate Cover forward. Be sure the unitis in soft watercycle (no water
pressure at nozzle and venturi). Then, holding the nozzle and venturi housing with one hand, turn off the cap.
Do not lose the o--ring seal. Lift out the screen support and screen. Then, remove the nozzle and venturi. Wash
the parts in warm, soapy water and rinse in fresh water. If needed, use a small brush to remove iron or dirt. Be
careful not to scratch, misshape, etc., surfaces of the nozzle and venturi. Also, check and clean the gasket and
flow plug(s).
Carefully replace all parts in the correct order. Lubricate the o--ring seal with silicone grease and locate in position.
Install and tighten the cap, by hand only. Do not overtighten and break the cap or housing.
*Install with Numbered Side Up
ConcaveSideDown.
Cap
O --- r i n g S e a l
Screen Support
Screen
Nozzle & Venturi
Gasket
*Flow Plug (HVDC)
Nozzle & Venturi
Housing
Screen
IMPORTANT: Be sure small hole in
the gasket is centered directly
over thesmallholeinthenozzle&
venturi housing.
*Flow Plug
(1---EP)
Ferrule Nut
Figure 14
27
ECOWATER
SYST E MS Troubleshooting Guide
Tools Needed For Most Repairs: 5/16 Hex Driver, Phillips Screwdriver, Needle---nose Pliers
PROBLEM CAUSE SOLUTION
REPAIR KIT(S)
NEEDED
No Soft Water 1. No salt in the storage tank a. Refill with salt (see page 25)
b. UseRechargeNowfeature(page21)
None
No Soft Water Timer
Display Blank
1. Transformer unplugged at wall outlet, or power
cable disconnected, Transformer OR POWER
CORD defective
a. Check for loss of power and correct. Reset timer
andusetheRechargeNowfeature(page21)
Transformer Power
Cord
2. Fuse blown, circuit breaker popped, or circuit
switched off. (See page NO TAG “Timer Power
Outage Memory”).
a. Replace fuse, reset circuit breaker, or switch
circuit on use the Recharge Now feature (page
21).
None
3. Timer control board defective a. Replace Electronic Control Board (page 28) Timer Control Board
No Soft Water Salt 1. Salt in storage tank bridged a. Refer to page 25 to break. None
Level Not Dropping 2. Manual bypass valve(s) in bypass position a. Seepage16figure10.Movesteminsingle
bypass to service
None
No Soft Water, Salt
Storage Tan
k
Full Of
1. Dirty, plugged or damaged nozzle & venturi a. Take apart, clean and inspect nozzle and venturi
(see page 23)
Nozzle Kit
S
t
o
r
a
g
e
a
n
k
F
u
l
l
O
f
Water, Water
R
i
h
2. Inner valve defect causing leak a. Replace seals and rotor (page 28) Rotor/Seal Kit
,
Running To The
Drain (While Unit Is
I
h
S
f
W
3. Valve drain hose plugged a. Hose must not have any kinks, sharp bends or
any water flow blockage (see page 8)
None
(
In The Soft Water
Cycle
4. Low or high system water pressure (low
pressure may disrupt brine draw during
recharge, high pressures may cause inner valve
parts failure)
a. If pressure is low, increase well pump output to a
minimum 1.4 bar. Add a pressure reducing valve
in the supply pipe to the softener, if daytime
pressure is over 7 bar.
None
5. Brine valve float kit dirty or defective a. Clean Brine or replace valve float kit assembly
(page 28)
Float Kit
6. Leak between valve and resin tank assembly a. Replace Tank/Valve O---Rings Tank/Valve O--- ring Kit
Water Hard
S
1. Time setting wrong a. Check and change time setting None
Sometimes 2. Incorrect water hardness setting a. Refer to page 19 to find correct settings None
3. Incorrect model code programmed a. Refer to page 18 to find correct settings None
4. Hot water being used when softener is
regenerating
a. Avoid using hot water while the softener is
regenerating as the water heater will fill with
hard water. Check timer for correct settings
None
5. Possible increase in water hardness a. Test the raw water for hardness and iron and
program the timer accordingly (page 19).
None
6. Leaking faucet or toilet valve. Excessive water
usage.
a. A small leak will waste hundreds of gallons of
water in a few days. Fix all leaks and always fully
close faucets.
None
Iron In Water 1. Clear water iron in water supply
2. Iron in soft water
3. Bacterial or organic bound iron
a. Test the raw water for hardness and iron and
program the timer accordingly (page 19).
b. Clean resin bed with Resin Bed Cleaner
c. Cannot be treated by water softener
None
ResinInHousehold
Plumbing, Resin
Ta n k L e a ki n g
1. Crack in distributor or riser tube a. Replace resin tank assembly (page 28) Resin Tank Assembly
Salt Storage Tank
Leaking
1. Crack in brine tank a. Replace salt storage tank assembly (page 28) Salt Storage Tank
Assembly
Motor Stalled Or
Clicking
1. Motor defective or inner valve defect causing
high torque on motor
a. Replace Rotor/Seal kit (page 28)
b. Replace Motor & Switch
Rotor/ Seal Kit
Motor/Switch Kit
Error Code E1, E2,
E3, or E4 appears
1. Wiring Harness or Connection to Position Switch
2. Switch
3. Valve Defect Causing High Torque
4. Motor Inoperative
a. Replace Wiring Harness or Connection to
Position Switch
b. Replace Switch
c. Replace Rotor Seal Kit
d. Replace Motor
Motor/Switch Kit
Rotor/ Seal Kit
Error Code E5
appears
1. Faceplate a. Replace Electronic Control Board Electronic Control
Board Kit
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1 . U n p lu g t r a n s f o r m e r --- --- --- --- 2 . C o r r e c t d e f e c t --- --- --- --- 3 .
P l u g i n t r a n s f o r m e r --- --- --- --- 4 . W a i t f o r 6 m i n u t e s . T h e e r r o r c o d e w i l l r e t u r n i f t h e d e f e c t w a s n o t c o r r e c t e d .
28
ECOWATER
SYST E MS Service Information
Automatic Electronic Diagnostics
The faceplate computer has a self--diagnostic function for the electrical system
(except input power and water meter).The computermonitors electronic compo-
nents and circuits for correct operation. If a malfunction occurs, the computerat-
tempts to self correct, displaying ADJUST VALVE in the Normal View Screen. If
self correction fails, an error code appears in the faceplate display.
The chart below shows the error codes that could appear, and the possible defects for each code.
While an error code appears in the display, all faceplate keypads are inoperable except the SELECT keypad.
SELECT remains operational so the service person can make the MANUAL INITIATED ELECTRONIC DIAG-
NOSTICS, below, to further isolate the defect, to check the water meter and to send an E.A.S.E. transmission.
POSSIBLE DEFECT
CODE MOST LIKELY '-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 'LEAST LIKELY
Error 1 Error 2
Error 3 Error 4 wiring harness or connection to position switch / switch / valve defect causing high torque /
motor inoperative
Error 5 faceplate
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer-------- 2. Correct defect-------- 3.
Plug in transformer-------- 4. Wait for 8 minutes. The error code will return if the defect was not corrected.
Manual Advance Diagnostics
1.To enterdiagnostics, pressthe SELECT/EXIT()to enterthe menu.This screen con-
tains information that can be used to troubleshoot errors. Use the () and () keypads
to scroll through all lines on this screen.
The first line shows time of day and error code.
Second line is Pos: which shows what position the valve is in. Example: Service, Fill,
Brining and Brine Rinse,Backwash and Fast Rinse. The clockto the right counts back-
ward the time for each of the positions to be completed.
The next line is Req Pos: which is for requested position, or what position the valve is travelling to.
Next line displays Motor:, either on or off, and Sw: (switch) either open or closed.
Next is Trbn: (turbine) and Gals: (gallons) or Ltrs: (litres)which indicate water meter operation as follows.
000 (steady) = conditioned water not in use...no flow through the meter.
--open a nearby CONDITIONED WATER faucet--
000 to 199 (continual) = repeats displayfor each gallon (roughly 4 litres)of waterpassing through the meter. Gal-
lons up by one or litres up by 4.
If you don’t get a reading in the display, with a faucet open, pull the
sensorhousing from the valve outlet port. Passa smallmagnetback
and forth in front of the sensor. You should get a reading. If you do
geta reading, disconnect the outletplumbing and checkthe turbine
for binding. Ifyou don’t geta reading, the sensoris probably defec-
tive.
29
ECOWATER
SYST E MS Service Information
Use the recharge keypad to manually advance the valve into each cycle and check correct switch operation,
and observe the valve position indicator.
NOTE: The position switch is closed when the plunger is depressed, open when extended.
While in this diagnostic screen, the following information is available and may be beneficial. This information
is retained by the computer from the first time electrical power is applied to the faceplate.
...Remote: either Installed or Not Installed.
...Days: displays the number of days this faceplate has had electrical power applied.
...Rchg: to show the number of regenerations initiated by this faceplate since power was first applied.
NOTE: This number resets to 0 if the model code is changed.
...Last Rchg: displays the number of days since last recharge.
...Cap: displays numerically the capacity the softener is operating at with 1 lowest and 5 highest.
Press the SELECT/EXIT () to exit to the Advanced/Service menu, move cursor up to EXIT and press SE-
LECT/EXIT ()togotoNormalScreenViews.
Manual Initiated Electronic Diagnostics
This check verifies proper operation of the gearmotor, brine tank fill, brine draw, regeneration flow rates, and
other controller functions. Always make the initial checks, and the manual initiated diagnostics first.
1. Press the RECHARGE keypad. Move cursor down to Start Rchg Now and press SELECT/EXIT ()tostart
a recharge. As the EcoWater conditioner enters the fill cycle of regeneration, remove the brinewell cover and,
using a flashlight, observe fill water entering the tank.
a. If water does not enter the tank, look for an obstructed nozzle and venturi, fill flow plug or brine tubing Fig-
ure 14, page 26.
2. After verifying fill, press Recharge keypad to move the valve into brining*. A slow flow of water to the drain
will begin. Verify brine draw from the brine tank by shinning the flashlight into the brinewell and observing a
noticeable drop in the liquid level.
*If the 2ND BACKWASH option is set, the valve will enter backwash and fast rinse before brining, see page
23.
NOTE: Be sure water is in contact with the salt, and not separated by a salt bridge, see page 25.
a. If the unit does not draw brine, check for...
...dirty or defective nozzle and venturi, page 26
...nozzle and venturi not seated on the gasket, or gasket defective
...restriction in valve drain, causing a back-pressure (bends, kinks, elevated too high, etc.), installation step 8
...obstruction in brine valve or brine tubing, Figure 1, page 7
...inner valve failure (obstructed outlet disc, wave washer defective, etc.)
3. Again press Recharge keypad to move the valve into backwash. Look for a fast flow of water from the
drain hose.
a. If flow is slow, check for a plugged top distributor, backwash flow plug or drain hose.
4. Press Recharge keypad to move the valve to fast rinse position. Again look for a fast drain flow. Allow the
unit to rinse for several minutes to flush out any brine that may remain from the brining cycle test.
5. To return the valve to service position, press RECHARGE ONCE AGAIN.
30
ECOWATER
SYST E MS Repair Parts
1
31
30
28
27
26
23
25
24
22
21
20
19
17
16
15
18
8
7
9
3
4
5
6
10
14
13
11
12
29
2
31
ECOWATER
SYST E MS Repair Parts
KEY -
NO.
PART
NO. DESCRIPTION
130476 Rep’l PWA ESM 11 ED
30477 Rep’l PWA ESM 15 ED
27269257 Cap, 2 req’d
37269524 Brine Tube, ESM15CE
7269532 Brine Tube, ESM11CE
47113016 Tubing Assembly
57131365 Screen
67080653 Clip
77092252 Brine Valve Body
87116713 Clip
97113008 Float, Stem & Guide Asm., ESM15CE
7269508 Float, Stem & Guide Asm., ESM11CE
10 7266819 Salt Hole Cover
11 7219888 Brinewell Cover, ESM11CE & ESM15CE
12 7219595 Washer
13 7267027 Brinewell, ESM15CE
7267035 Brinewell, ESM11CE
14 7219587 Screw
15 7268934 Repl. Brine Tank, ESM15CE
7268926 Repl. Brine Tank, ESM11CE
KEY
NO.
PART
NO. DESCRIPTION
16 0900431 Hose Clamp
17 1103200 Hose Adaptor
18 9003500 Grommet
19 RMH001 Resin
20 7105047 Repl. Bottom Distributor
21 7264037 Resin Tank, 8 in. dia x 25 in., ESM15CE
7256377 Resin Tank, 8 in. dia x 19 in., ESM11CE
22 7088033 Clamp Retainer, 2 req’d
23 7176292 Clamp Section, 2 req’d
24 7170270 O --- r i n g S e a l , 2 --- 3 / 4 i n . x 3 i n .
25 7077870 Top Distributor, ESM11CE & ESM15CE
26 7170254 O ---ring Seal, 13/16 in. x 1 --- 1/16 in.
27 7170296 O --- r i n g S e a l , 2 --- 7 / 8 i n . x 3 --- 1 / 4 i n .
28 7237381 Vapor Barrier
29 7225499 Locking Plate
30 7258028 Faceplate Cover (order decal below)
7265295 Decal (for above cover)
31 7235460 Weather Cover
32
ECOWATER
SYST E MS Repair Parts
70
32
74
76
77
75
78
33
34
35
36
37
38
39
40
43
44
46
49
50
41
42
47
51
48
52
53
54
55
56
57
58
59
60
65
61
62
63
64
66
67
68
69
71
73
72
45
33
ECOWATER
SYST E MS Repair Parts
KEY
NO.
PART
NO. DESCRIPTION
32 7070412 S c r e w, # 4 --- 2 4 x 1 --- 1 / 8 i n .
33 7117816 Spacer
34 7030713 Switch
35 7077472 Expansion Pin
36 7074123 Screw,#1014x2in.(5)
37 7199729 Cap
38 7170262 O---ringSeal,1.1in.x1.4in.
39 7167659 Screen Support
40 7146043 Screen
41 0521829 Flow Plug, .1gpm
42 7095030 Cone --- Screen
43 7248007 Nozzle & Venturi, w/Gasket Kit, ESM11CE
& ESM15CE
7190547 Gasket (only)
44 1148800 Fill Flow Plug, .3 gpm, ESM11CE &
ESM15C
45 1202600 Nut --- Ferrule
46 7081104 Nozzle & Venturi Housing
47 7081201 Retainer
48 7081764 Seal (Nozzle & Venturi)
49 7170319 O---ringSeal,1/4in.x3/8in.(2)
50 7082053 Valve Body
51 7129889 Spring
52 7092642 Plug (Drain Seal)
53 7170204 O---ringSeal,3/8in.x9/16in.
KEY
NO.
PART
NO. DESCRIPTION
54 7134224 Rotor Seal / Wear Strip
55 7170246 O --- r i n g S e a l , 3 --- 3 / 8 i n . x 3 --- 5 / 8 i n .
56 7199232 Rotor & Disc
57 7082087 Wave Washer
58 7170212 O ---ring Seal, 3/4 in. x 15/16 in.
59 7170238 O ---ring Seal, 7/16 in. x 5/8 in.
60 7085263 Valve Cover
61 7170327 O ---ring Seal, 5/8 in. x 13/16 in.
62 0900431 Hose Clamp
63 7024160 Drain Hose Adaptor
64 7142942 Clip
65 0501228 Flow Plug, Backwash / F. Rinse control
66 7113927 Cam and Gear
67 0503288 Bearing
68 7231385 Motor Plate
69 0900857 Screw, #6 --- 20 x 3/8 in. (2)
70 7250622 M o t o r --- I n c l u d e s K e y N o . 7 1
71 7224087 Screw, #6 --- 20 x 7/8 in. (2)
72 7170288 O---ring (2)
73 7116713 Clip (2)
74 7248714 Sensor Housing/Wiring Harness Asm
75 7113040 Turbine and Support Assembly
76 --- --- Turbine Support
77 --- --- Tu rb in e
78 0900060 O---ring Seal
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ecowater Systems ESM15CE bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ecowater Systems ESM15CE in de taal/talen: Engels als bijlage per email.

De handleiding is 0.68 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info