• Teide model. Connection for lateral convectors.
• AIRTIGHT INSTALLATION. "DIFLUX" mounting and
direct connection to the outside. Air intake pipe
connection.
LOCATION AND SAFETY DISTANCES.
4.11. Do not install the stove in a sleeping room.
4.12. Install a fire protection between the ground and the stove if the floor is a combustible material.
4.13. Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Ensuring a
better access to the stove for future maintenance or repair work is also worth considering.
Drawing 6
INSTALLATION OF BUILT-IN STOVES
The measurement of the lateral ventilation openings indicates the effective area of air passage through
them. If a decorative grid is placed, the effective area of air passage of the said grid must coincide with the effective
area of passage of the openings, varying the dimensions (height and / or width) of the grids to achieve the right air
passage area.
Drawing 7 shows the minimum permitted dimensions of the built-in space (non-flammable material) with
respect to the stove and the position of the ventilation grids, for the installation of the Córdoba, Córdoba ducted,
Teide and Granada models.