536311
2
Verklein
Vergroot
Pagina terug
1/3
Pagina verder
3. Installation
The controller should be arranged in a place within the
room which:
is easily accessible for operation
is free from curtains, cupboards, shelves, etc.
enables free air circulation
is free from direct sun radiation
is free from draughts (e.g. opening of windows and doors)
is not affected directly by the source of heat
is not located on an external wall
is located approx. 1,5 m above floor level
Mounting directly on conduit box or with adapter
frame ARA easy.
Electric connection
Warning! Disconnect electric circuit from supply
Proceed as follows:
pull off temperature setting knob
push retaining hook outwards using screwdriver
remove housing cover
make connection in compliance with wiring diagram (see
housing cover).
watch notes
4. Technical data
Temperature setting range:
comfort temperature 530°C
setback temperature 5…30°C
Regulation proportional controller (due to
PWM quasi-continuous, see Fig. 1)
Cycle period adjustable 10 or 25 min.
(sum of PWM ON and OFF times)
Proportional band 1.5 K
Hysteresis at ~0,5 K 10 A (see fig. 2)
~2,5 K at 16 A
ON/OFF regulation adjustable via jumper
Output relay, 1 volt-free*
changeover contact
Switching current 10 mA16 A cos ϕ = 1
max. 4 A cos ϕ = 0,6
max. 10 electro-thermal actuators
Switching voltage 24250 V AC
Time switch output max. 20 temperature setback inputs,
230 V: max. 50 mA,
24 V: max. 150 mA
Mode selector switch comfort / automatic / setback
Indicator lamp: red controller demands heat
green setback mode
Temperature sensor internal
Range limitation inside setting knob
Clock: accuracy <10 min./year
switching time setting every 15 min. with daily timer
every hour with weekly timer
power reserve approx. 100 h
Protection class of housing IP 30 / insulated
Degree of protection II (see Warning)
Ambient temperature 10…40°C, without condensation
Storage temperature –25…65 °C
Dimensions 160 x 80 x 36 mm
Weight approx. 220 g
* The volt-free contact of this mains-operated unit does not
ensure the requirement for the use of safety extra-low voltage
(SELV).
For units with 230 V supply voltage
Type easy 3pt with daily timer
easy 3pw with weekly timer
Article-Nr. easy 3pt 517 2703 51 100
easy 3pw 517 2704 51 100
Operating voltage 195…253 V AC 50/60 Hz
Power consumption <1.5 W
For units with 24 V supply voltage
Type easy 3pt/24 with daily timer
easy 3pw/24 with weekly timer
Article-No. easy 3pt/24 517 2703 21 100
easy 3pw/24 517 2704 21 100
Operating voltage 2030 V AC 50/60 Hz
Power consumption < 1.5 W
1. Applications
The easy 3p electronic clock thermostat is designed for
room temperature control in conjunction with:
heating systems, e.g. hot-water heaters, convector hea-
ters or floor heating
electric convector heaters, ceiling and storage heating
night-storage heaters
circulation pumps
burners and boilers
heat pumps, etc.
Airconditioning applications (cooling only)
other temperature controllers can be controlled
via time switch output.
Features
very simple operation
comfort and setback temperature adjustable
3 operating modes for:
permanent comfort temperature (5…30°C)
permanent setback temperature (5…30°C)
clock mode (automatic)
Indicator lamps for:
heat demand
setback mode
time switch output (for temperature setback of other
temperature controllers)
available with daily or weekly timer
output signal PWM or ON/OFF regulation (adjustable via
jumper)
relay output, 1 x changeover contact
hinged cover
new design
2. Function description
The clock thermostat is designed to control the room tem-
perature.
In the automatic mode, a changeover is effected between
comfort and setback mode by the built in timer.
In setback mode the green indicator lamp lights up.
If room temperature drops below set value, heating will
start, the red indicator lamp will light up.
Indicator lamps
Red indicates when controller demands heat,
Green indicates when setback mode is activated.
Red flashing for failure.
Operating voltage to be switched OFF and ON again.
Temperature setback of other temperature
controllers
Temperature setback inputs of other temperature control-
lers can be connected to time switch output (terminal 28).
They are then controlled by the time switch.
The position of the mode selector switch (see 6.6) influen-
ces this output accordingly.
Controller heat demand at PWM
If room temperature drops below the set value, heating
mode will start. The controller output is in the form of pul-
ses of varying length (PWM). The length of the pulses
depends on the difference between set and actual room
temperature.
The sum of pulse and pause times can be selected with
J4 (between 10 or 25 min.).
If there are large temperature differences, the controller
will switch ON or OFF permanent, e.g. when changing
over to temperature setback mode. Use PWM only at
current 10 A.
Fig.1: Characteristic of impulse pause ratio depending on temperature
Cycle time setting
For inert applications (e.g. burners) we recommend the
long cycle time.
For quick applications (e.g. electric direct heaters) we
recommend the short cycle time.
Plug-in jumper J4 Time
(right side of board)
Double-pole jumper 25 min
connection (as-delivered condition)
Single-pole jumper 10 min
connection
Heat demand of the controller at ON/OFF regulation
When room temperature drops below set temperature the
output will be switched on, whereas it will be switched off,
when set value is exceeded.
Fig. 2: ON/OFF regulation
Plug-in jumper J3 Regulation
(right side of board)
Double-pole jumper ON/OFF
connection
Single-pole jumper PWM
connection (as delivered condition)
set temperature
temperature
OFF
ON
Hysteresis
On
Off
Temperature
10/25 min
set temperature
For units with low voltage output
Type easy 3pt with daily timer
easy 3pw with weekly timer
Article No. easy 3pt 5172713 51100
easy 3 pw 517 2714 51 100
Operating voltage 195…253 V AC 50/60 Hz
Switching current >1V/>1mA…max 250 V/AC 10 A
Power consumption <1.5W
5. Wiring diagram
Symbol explanation
U Heating P Cooling
TA Temperature set-back for other controllers
Note
For heating applications
connect n/c actuators to terminal 2.
connect n/o actuators to terminal 3.
For cooling applications
connect n/c actuators to terminal 3
connect n/o actuators to terminal 2
To use the red lamp U as indicator for “Ccooling
ON”, connect n/o actuators to terminal 2
6. Operation
Temperature setting
Comfort temperature (daytime temperature)
is set by means of externally visible setting knob (1)
Setback temperature (night temperature)
is set by means of adjustment knob (2) beneath
cover.
Time setting
by putting one finger on dial (3) and turning in any
direction, you can set the time.
Arrow (4) points to the selected time.
Switching time setting
Bring movable tappets (5) into required position
using a pointed object.
Outer ring = comfort temperature
Inner ring = setback temperature
Mode selector switch (6) – internally
É Comfort temperature, permanent
2 Automatic mode, time-controlled changeover
between comfort and setback temperature
Setback temperature, permanent
21
1
4 5
0
3
6
9
12
15
18
36
2
Ñ
6
5
4
3
2
1
U 468 931 002 915-05
Installation and
Operating Instructions
Electronic
Clock Thermostat
easy 3p
Warning!
This unit must not be opened and installed
except by authorized persons and in compli-
ance with the circuit diagram provided inside
the cover. It is mandatory in all work on the
unit to observe the current safety regulations.
In order to classify for protection class II it is
necessary to take adequate installation mea-
sures.
This separately mounted unit is designed for
temperature control exclusively in dry and
closed rooms with standard environment. The
unit features radio-interference suppression
in compliance with VDE 0875 T.14 and
EN 55014, respectively and works according
to operating principle 1 C (EN 60730).
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw EBERLE Easy 3P bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van EBERLE Easy 3P in de taal/talen: Duits, Engels, Frans als bijlage per email.

De handleiding is 0,13 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info