ID Feature: Description: Factory Pre-Set:
5 BACKLIGHT Available options are: On with timeout (TIMED), Always Off (OFF) TIMED
7 LOCK Protect MiStat against unauthorised use. If active, any key press will show LOCKED for a few Secs.
To lock: Enter your 3 digit code for protection.
To unlock: Press +&- key for approx. 5 sec. Enter your 3 digit code
000
Master code 401
10 VALV-PROT The output will be activated for the speci ed time (in Minutes). This will happen weekly, related to
the last actuation of the output. Select OFF, 1 to 10 Minutes.
OFF
11 WIRELESS To create a radio link with the receiver or to view the RF signal quality Pre-bound
12 BIND Press (
) key to start connecting to the receiver.
NB. “binding” must also be activated on the receiver, see Step 6 Commissioning
BINDING An RF connection to the receiver will be created. If successful, the SIGNAL level will be displayed.
If unsuccessful, FAILED will be displayed.
13 SIG-LEVEL Indicates the quality of the RF transmission
VERY GOOD, GOOD, POOR, NO SIGNAL
DONE To exit WIRELESS sub menu
15 PROD-INFO View the product details, e.g. Part number, Firmware revision etc. Use (
) key to show the details
16 RESET Will reset all settings to factory pre-sets OFF
DONE Exit from the settings menu to INST-S
INSTALLATION Guide
Step 3: Signal Strength
The MiStat Cylinder thermostat is prebound to the MiStat
receiver in the factory so they just need to be positioned
in the best place for wireless communication. To help
with this there is a built in Signal strength indicator,
available in the Installer settings menu on the MiStat
thermostat, as shown.
It is recommended that the signal strength is Good
or Very Good to ensure ongoing communication is
maintained.
To enter signal strength menu (see step 5 for more detail)
Press + & - for approx. 5 secs, then scroll (+/-) to show
INST-S,
• press (
) to enter the installer menu,
• Press +/- until 11 WIRELESS is shown,
• press ( ) to enter,
• press +/- to show 13 SIG-LEVEL as shown,
• press ( ) to see the current signal strength.
Step 4 (Continued) Step 5: Installer Settings
Customize the MiStat according to application needs.
Step 1: Mounting the Wallplate
Step 2: Wiring
! IMPORTANT:
Installation must only be carried out by a
qualifi ed electrician or heating engineer.
Make sure mains input has a 3 amp fuse.
! CAUTION! Before installation, make sure the
mains supply is switched off!
Option 2: Using an existing wall-plate
Loosen the securing screws on the old receiver
and unplug it. Check that there’s 20mm clearance
to the right of the wall-plate and 25mm above it.
Check the wiring diagram for your product model
to compare terminals and, if necessary, change
the wiring of the wall-plate to suit. Now plug the
MiStat R unit into the wall-plate and tighten the
securing screws.
Check the 3A fuse, and switch on the mains.
Option 1: Fitting a new wall-plate
The ideal location is close to the boiler or central
heating system. For the best performance install
in an open space, at least 30cm distance from
any metal objects including wall boxes and the
boiler housing. It is recommended that the
MiStat R is mounted on the wall nearest the fi nal
location of the MiStat C room unit and not less
than 30cm from the boiler side panel.
Loosen the securing screws, remove the
wallplate and, if surface wiring is to be used,
snap out the cable entry strip on the bottom
edge of the wallplate with a pair of pliers. Fix the
wallplate, terminals at the top, either direct onto
the fl at wall using wall plugs and no 6 x1” wood
screws or on a plastic fl ush mounting single
conduit box using M3.5 x 14 screws. Check that
there’s 20mm clearance to the right of the wall-
plate and 25mm above it. Complete the wiring
to the MiStat R wallplate in accordance with the
wiring diagram in step 2, to comply with current
IEE regulations. Place the MiStat R onto the
wallplate and tighten the securing screws.
Check the 3A fuse, and switch on the mains.
Warning: Installing the MiStat R too close to the
metal side panel or mains cables may interfere
with the radio signal.
! DO NOT
use a surface
mounting box
This product is double insulated and
does not require an earth connection.
The MiStat R should be wired to the
boiler or central heating wiring using the
correct type of cable or fl ex. The MiStat
R should be wired to replace hard wired
room or programmable thermostats,
as shown on the system or boiler wiring
diagrams.
Always check other manufacturers
instructions for compatibility.
Combi boiler basic wiring layout
Zone control basic wiring layout
Note: If not bound, the bind screen will be visible.
For commissioning see Step 6
Note: Only needed if not already bound, ie if
replacing either the MiStat thermostat or the
MiStat receiver.
To exit Installer Settings
Press +/- until ‘DONE’ is shown, then press ‘Select’ or
press + & – keys for approx. 5 seconds to exit. If there
is no key pressed for 2 Minutes, the system will exit the
menu, any changes will be saved.
1. Turn on power for the receiver. The red lamp will
come on. (if green lamp is visible, the device is
already bound, no further action needed here)
(If a separate programmer/Timer is fi tted, ensure
that it is switched on)
2. Push the button for >5 Seconds and the LED will
ash red – yellow – green --- -red – yellow - green…
3. Enter binding mode on the corresponding
MiStat room unit, see Step 5: Installer settings ,
it em 11
Important: It is essential, that the binding is
carried out between the corresponding room
unit and the receiver
4. If binding is successful, the signal strength will
be indicated on both the MiStat room unit and
the MiStat receiver as follows. If unsuccessful,
FAILED will be displayed. If POOR SIGNAL
is displayed, look for a better location. If NO
SIGNAL is displayed, try connecting again with
the room unit in a different position.
MiStat Room Unit
MiStat Receiver
Immediately after binding, these signals will indicate
the signal quality for 1 minute.
three green fl ashes = Very good signal
double amber fl ashes = Good signal
single red fl ashes = Poor signal
steady red = No signal
To check the wireless connection
A green lamp on the receiver will indicate a good RF
connection.
To enter Installer Settings
Press + & – keys for approx. 5 Seconds to enter the
settings menu as shown.
Note: If not bound, the bind screen will be visible.
For commisioning see Step 6
Technical Data
Step 6: Commissioning
MiStat C110C & MiStat R111M
Supply voltage MiStat C: 2 x AA 1,5V alkaline
batteries
MiStat R: 230V
Switch rating MiStat R: 2(1)A 230V a.c.
Ambient
temperature
Operating: MiStat C 0°C to 50°C;
MiStat R 0º to 4C
Storage: –20°C to 55°C;
Battery life MiStat C: 2 years (typically)
Temperature
range
40°C to 70°C
Control accuracy +/- 8°C
Wiring MiStat R: Fixed wiring only, to comply
with current IEE regulations (BS7671)
MiStat C: No wiring required
MiStat Sensor: Ø0.5mm2 2 core
cable between Sensor & MiStat.
Mounting MiStat R: Industry standard wallplate
MiStat C: Wall bracket
MiStat Sensor: Direct mounting onto
cylinder
Radio frequency 868.3 (Bi-directional communication)
Radio signal range 30m typically. The range may be
affected by the composition / density
and number of walls between the
MiStat C and MiStat R
Pollution degree 2
Software class A
Rated impulse
voltage
MiStat R: 2.5kV
Ball pressure test
temperature
MiStat R: 75°C
Energy class I = 1% (According to EU 811/2013,
812/2013, 813/2013, 814/2013)
Relevant EC
Directives:
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic
Compatibility Directive
1995/5/EC R&TTE Directive
2006/66/EC Battery Directive
2011/65/EU RoHS Directive
Applied
Standards:
EN60730-1; EN60730-2-9
ETSI EN 300 220-3; ETSI EN 301 489-3
eg. eg.
eg. eg.
User Code:
N L 1 2 3
L
MiStat R
MiStat R
Switched live
from wiring
centre
Motorised valve
N
To boiler
and/or
pump
Radio signals
to MiStat R - no wiring
230V AC
fused 3A
N L 1 2 3
L -
N -
Radio signals
to MiStat R - no wiring
Sw
i
tched
230V AC
fused 3A,
Internal
boiler
electronics
External
controls
connections
N L 1 2 3
L
MiStat R
MiStat R
Switched live
from wiring
centre
Motorised valve
N
To boiler
and/or
pump
Radio signals
to MiStat R - no wiring
230V AC
fused 3A
N L 1 2 3
L -
N -
Radio signals
to MiStat R - no wiring
Sw
i
tched
230V AC
fused 3A,
Internal
boiler
electronics
External
controls
connections
If POOR is displayed, look for a better location.
If NO SIGNAL is displayed, try connecting again with
the room unit in a different position.
Step 4: Mounting Options
The MiStat C should be located in a convenient position
for the end user, close to the domestic hot water cylinder
being controlled.
Once the best position has been identi ed, the MiStat
C should be fi xed to the wall using the wall bracket as
shown.
MiStat
Wiring
Cylinder Thermostat
Cylinder Thermostat Sensor
Locate the external sensor terminal block on the lower
edge of the MiStat C thermostat, connect a 2-core
cable, cut to the required length to reach the sensor
position. Connect to the sensor in the position shown
and fold wires back through the cable grip & out
through the cable entry, re-assemble the housing.
Clip the spacer
provided onto
the sensor
housing
The sensor should be installed approximately one
third of the way up the hot water cylinder. With pre-
insulated cylinders, mark the position and size, and
remove just enough insulation to allow the sensor to fi t
against the metal of the cylinder in the recess formed.
The plastic covered spring fi xing cable should be cut
to an un-stretched length of approximately 60-75mm
(2½”-3”) less than the circumference of the cylinder
and the hook and eyelet should be screwed into the
ends. Stretch the cable round the cylinder, over the
insulation, and position it in the groove across the front
of the sensor housing, Engage the hook and eyelet.
1/3 cylinder height
Cylinder
Insulation
Fixing cable
Sensor
Sensor
Cylinder
Cable entry
Connect here NTC
Sensor
Cable
grip
External
Sensor
Client Invensys File Name 7449 Instruction Manual Amends 6490192_F V2
Artworker -
Proof Stage
PRINT
Finished Size A3 297x420mm
Creative Director Mike Lane Artwork % 100%
Modification Date 18/06/15 10:26AM Bleed 3mm
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Drayton MiStat C - C110C bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Drayton MiStat C - C110C in de taal/talen: Engels als bijlage per email.

De handleiding is 3,85 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info