8. Press the Yes (–) button again.This tells you that at
6.30, the heating system will control your home at
20°C. If you wish to alter the temperature use the +
and – buttons.
9. Press the “SET?” button.The time will now flash. If
you wish to alter the switching time use the + and –
buttons.This will change the switching time in 10
minute steps.
10. Press the “SET?” button, this tells you that at 8.30,
the heating system will control your home at 16°C. If
you wish to alter this temperature use the + and –
buttons.
11. Continue to press the “SET?” button as in steps 9 and
10 above to advance through the times and
temperatures for Mon. to Fri. (1 – 5). If you wish to alter
any of the times and temperatures use the + and –
button, when the one you wish to alter is flashing.
12. Once Mon. to Fri. have been set, the display will show
as here. This means do you want to set the times for
Monday (1) differently from the rest of the week? If you
do, press the Yes (–) Button, and follow the routine as
steps 9 to 11.
13. Continue to press the “SET?” button to advance
through the week (1 – 5).When this display shows,
press the Yes (–) button if you wish to view or alter
the times for Sat.-Sun. (6-7). Repeat steps 9-12 as
required.
14. Continue to press “SET?” button until you return to
normal operating mode with a display similar to the
one shown here.
OPERATING MODES
The Digistat can be operated in one of three modes.
1) – Timed, all preset times and temperatures
2) – Continuous night temperature (useful for low limit temperature
protection when on holiday)
3) – Continuous ‘DAY 1’ temperature
Use the SELECT button to change the operating mode to suit your
requirements, the symbols are positioned on the right hand side of the display.
TEMPERATURE OVERRIDE
If at anytime during normal operation, you wish to temporarily increase or
decrease the set temperature use the + or – buttons to change to your
desired setting. This can be done without entering the SET mode. 5 seconds
after releasing the + or – button the display will revert to showing the actual
room temperature. The Digistat will now control the temperature to the
override setting until the next programmed switching time, when it will revert
to the times and temperatures you have already programmed.
The Digistat RF3i features unique self learning optimum start software.They can
help achieve savings in excess of 10% on heating costs and reduce CO
2
emissions,
by delaying the start time on milder days without affecting your comfort level.
USER INSTRUCTIONS FOR OPTIMUM START
There is no extra programming involved. The self learning software is factory
preset and will start to monitor and adjust the heating start times for setting ,
as soon as the unit is installed.
The optimum start feature only operates on the first switching time of each
day ( ). Switching times , and switch at the programmed times
without any delay.
The delay period can vary between 0 - 60 minutes depending on:
a) The actual room temperature at the first switching time ( ).
b) The set temperature of the Digistat RF3i.
c) The stored data on how fast the heating system responded the previous day.
During normal operation the flame symbol on the display indicates the
current operating status.
Flame on = heating on
No flame = heating off
FIashing flame = saving energy (optimum start cycle operating)
When the flame is flashing, the optimum start cycle can be overriden by pressing
the + button once.This returns the unit to normal operation.
IMPORTANT
Always set your heating to the time that you would normally wish it to start
allowing for the coldest weather conditions. Optimum start will automatically
delay the start time and save you money on milder days.
DIGISTAT RF3i
Once the ‘wireless system’ has been commissioned,
the unit will display the actual room temperature
and the time at somewhere after 12.00 midnight
(Diagram A).
Note: If this unit has replaced a standard room
thermo-stat and/or a programmer is incorporated in
the control system, it is suggested that the central
heating (CH) channel is switched to On/Cont/24hrs.
Operation of the heating times and tempera-tures
will be controlled by this unit.
Diagram A Diagram B
Digistat RF3i has an indicator to show when the heating system is ON or OFF,
e.g. if the SET temperature is 20°C and the actual room temperature is below
20°C a flame symbol will appear on the display (Diagram B). This indicates a
demand for heat (system will switch ON).
During normal operation, the Digistat RF3i will display actual room
temperature continuously.
SETTING THE TIME OF DAY (STEPS 1-5)
THE DIAGRAM NEXT TO EACH STEP DESCRIPTION SHOWS RESULTING DISPLAY.
1. Press “SET?” button
2. Press “Yes” (–) button.The hours will flash as Fig. 2.
Use the + and – buttons to set correct hour.
3. Press “SET?” button again and the minutes will flash,
use + and – buttons to set correct minute time.
4. Press “SET?” button, day of the week will flash,
1 = Monday, 7 = Sunday, use + and – buttons to set
correct day.
5. Press “SET?” button twice to return to normal operating
mode.
PRE-PROGRAMMED TIMES AND
TEMPERATURES
The Digistat RF3i comes with the following preset programme.
Symbol Mon-Fri Sat-Sun Temperature
Time Time
6.30 7.00 20°C
8.30 9.00 16°C
4.30 pm 4.00 pm 21°C
10.30 pm 11.00 pm 7°C*
* 16°C if selector pin removed, see installation instructions.
TO VIEW OR CHANGE THE FACTORY SETTINGS (steps 6-14)
6. Press the “SET?” button until this display is shown.
7. Press the Yes (–) button.You have selected the Monday
to Friday part of the programme.