Check List
14
5.11
Failure : No cooling (the aggregate at the back of the device is cold).
Possible Cause Self Help Authorised Service
a.) The thermostat is set to 0.
b.) The device plug is not
plugged in.
c.) No voltage in socket.
d.) Defective electronics or
sensor feelers.
e.) Defective heating cartridge.
f.) The device is in its defrosting
phase.
a.) Set temperature control to
middle position.
b.) Plug in device plug.
c.) Check building fuse.
f.) See operating instruction
5.3
d.) Install new
electronics or sensor.
e.) Install new heating
cartridge.
Failure : No cooling (the aggregate is warm).
Possible Cause Self Help Authorised Service
a.) The device is not level.
b.) The device was only
switched on a short while
ago.
c.) Defective cooling aggregate.
a.) Level the device using a
spirit level.
b.) Switch on the device and
let it run for 5-6 hours.
c.) Check whether
repair is feasible.
If not, exchange
device.
Failure : Poor Cooling Performance.
Possible Cause Self Help Authorised Service
a.) The cooling aggregate is not
sufficiently ventilated.
b.) The device is exposed to
direct sunlight.
c.) The fridge door does not
close tightly.
d.) Light permanently on when
door closed.
e.) The fridge was stocked a
short while ago.
a.) Check that the ventilation
grids are not covered.
Check that device has
been installed properly
(installation instruction 4.5).
b.) Follow installation
instruction 4.5.
c.) Check installation is in line
with 4.5.
e.) Check fridge after 5-6
hours for proper cooling
function.
c.) Is door magnet there?
Install new door, if
required.
d.) Replace lighting sen
sor. Install new door,
if required.
Failure : Frost formation in fridge.
Possible Cause Self Help Authorised Service
a.) The fridge door does not
close tightly.
a.) Check installation is in line
with 4.5.
a.) Is door magnet there?
Install new door.