12
Installation
4.1.3 Gas connection
The correct connection of the fridge has to
be carried out by a skilled specialist.
Note the particularly valid national rules for
usage of LG-driven appliances.
- Technical Standards EN 732
A preset pressure regulator (1), Fig. 3, has
to be installed within the supplying line to
the fridge. The fridge must not be operated
with any other pressure than the one indi-
cated on the rating label.
The fridge has to be connected to the gas
bottle with a security hose
Choose a sufficient length to connect the
hose pipe without kinks. The hose must
not be longer than 1.5 m.
The gas connection to the appliance is
effected by means of a suitable coupling
tube fitting L8, DIN 2353-ST, complying
with EN 1949 (e. g. Ermeto).
The hose has to be replaced within the
intervals settled in the particular national
rules.
After having connected the gas bottle, a
leak test at all joints and a burner flame test
have to be carried out. Use a leak indica-
ting spray or a foaming agent carrying out
the leak test. After having opened the bott-
le valve check the joints for bubbles
Never use a naked flame to check the
appliance for leaks.
DANGER !
The refrigerator should only be operated using
liquid gas (propane, butane).
Do not use town gas or natural gas.
1
Bottle valve
Fig. 3
Fig. 5
Fig. 6
SW 14
SW 17
Detail
2. Adjust door handle
at the door and screw
onto it.
1. Fixing points:
use true-to-scale tem-
plate (1) (see Item
5.14)
3. Attach cover and fix
by pushing.
4.2 Assembling the doorgrip
1
Fig. 4
Template
1
Ø 2mm