93mm
305mm
Energy Related Product Directive
Type of heat output/ room temperature control
With electronic room temperature control Yes
Electronic room temperature control plus week
timer Yes
With open window detection Yes
Model Identifier(s):
B075E C100E D150E E200E
Nominal heat
output Pnom 0.75 kW 1 kW 1.25 kW 1.5 kW
Height (mm)
659 659 659 659
Width (mm)
570 840 1105 1373
Depth (mm)
50 50 50 50
Minimum heat
output (indicative) Pmin 0.75 kW 1.00 kW 1.25 kW 1.5 kW
Maximum continu-
ous heat output Pmax,c 0.75 kW 1.00 kW 1.25 kW 1.5 kW
Auxiliary electricity Consumption
At nominal heat
output elmax 0.00 0.00 0.00 0.00
At minimum heat
output elmin 0.00 0.00 0.00 0.00
In standby mode elSB <0.0005 <0.0005 <0.0005 <0.0005
With open window detection Yes
This product complies with Lot20 of the Energy Eciency Directive (2015/1188)
General Information
Please read the instructions closely before first using the product.
The necessary wall mounting brackets are provided with the product as a
standard.
It should only be operated when in the upright position as shown - see Fig.1.
All models are IP20 rated. Before connecting the heater check that the supply
voltage is the same as that stated on the heater.
For further information on heater guards, please contact our guard supplier
direct on Tel. No. 020 7987 1184 or visit www.aianos.co.uk, or in case of diculty
or for further advice contact the Customer Helpline.
Wall Mounting
IMPORTANT - The radiator must only be mounted using the kit supplied
WARNING - This product is heavy and care should be taken in installation
Select a suitable position on a wall, near to a mains power outlet. The radiator
should not be mounted closer than 75mm from the floor - see Fig. 2 (to enable
cleaning), or adjacent side walls. Ensure at least 305mm clear space between
the radiator and any overhanging shelf. It should not be mounted closer than 1
metre from the ceiling.
STEP 1: Check that you have all the necessary components:
(a) 2 x Bottom wall brackets
(b) 2 x Top wall brackets
(c) 2 x Radiator securing brackets
(d) 2 x Self-tapping screws.
STEP 2: Using a straight edge, draw a horizontal line (see ‘Y’ in Fig. 2) for the
bottom brackets at the required mounting height from the floor.
75mm
(min)
‘C’
‘Y’
75mm
(min)
Fig. 2
Fig. 3
Fig. 4 Fig. 5
Electrical Connection
Place the bottom brackets centrally over these centres with the top row of holes
on the line, and mark the fixing hole positions – see Fig. 2.
STEP 3: Drill the holes and fit wall plugs. Screw the bottom brackets in position
– see Fig. 2.
STEP 4: Measure dimension D in Fig. 1 according to model, from the top of the
bottom brackets and draw a horizontal line. Mark o the fixing centres for the
top brackets in line with the bottom brackets. Place each top bracket on the
line and mark the fixing holes – see Fig. 3. Drill and plug the wall and fix the
top brackets in place.
STEP 5: Place the radiator on the bottom brackets, then fit each securing
bracket to the top of the radiator and secure it with the self-tapping screw
provided – see Fig. 4.
Check that the radiator is securely fixed to the wall.
This guide is for quick reference only
To view the full manual, please visit - www.dimplex.nl
NOTE - The bottom of the radiator must not be less than 75mm from the
floor. To achieve this the top edge of the bottom brackets must be at least
160mm from the floor - see Fig 2. On this line, mark o the fixing centres
according to model - see `C’ in the table in Fig. 1 and Fig. 2
IMPORTANT - For safe clearances from shelf/obstacle - see Fig. 5
(max)
(min)
The electrical installation must be carried out by a competent electrician,
and be in strictaccordance with the current I.E.E. Regulations for Electrical
Equipment in Buildings. The wires in this mains lead are coloured in accordance
with the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
The heater is fitted with a length of flexible cable type H05VV-F size 3 x
1.0mm2 for connection to the fixed wiring of the premises through a suitable
connection box positioned adjacent to the heater.
A means for disconnection must be incorporated in the fixed wiring of the
premises in accordance with the wiring rules. The supply circuit to the heater
must incorporate a double pole isolating switch having a contact separation
of at least 3mm.
WARNING - THIS APPLIANCE MUST BE EARTHED
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Dimplex MK1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Dimplex MK1 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0.91 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info