798326
28
Verklein
Vergroot
Pagina terug
1/100
Pagina verder
EN-2 452162.66.04 · FD 9912 www.gdts.one
English LAW 9IMR - LAW 14ITR
1 Please read immediately
1.1 Important notes
ATTENTION!
!!
Never use cleaning agents containing sand, soda, acid or
chloride, as these can damage the surfaces.
ATTENTION!
!
!
Before opening the device, ensure that all electric circuits are
disconnected from the power supply.
ATTENTION!
!
!
The indoor unit is to be fixed to the transport pallet with
screws.
ATTENTION!
!
!
In an unfilled state (buffer tank and domestic hot water
cylinder without water), the device has a tendency to tilt in the
direction of the hydraulic assembly. Do not lean on the rear of
the unit!
ATTENTION!
!!
With fully demineralized water, it is important to ensure that
the minimum permissible pH value of 7.5 (minimum
permissible value for copper) is complied with. Failure to
comply with this value can result in the heat pump being
destroyed.
ATTENTION!
!
!
Operating the heat pump at low system temperatures may
cause the heat pump to break down completely. After a
prolonged power failure, the commissioning procedure
detailed above must be followed.
ATTENTION!
!
!
Work on the system must only be performed by authorised
and qualified after-sales service technicians!
ATTENTION!
!
!
Incorrect filling with refrigerant could lead to faults during
operation.
ATTENTION!
!!
Never open the valves of the outdoor component. Carry out
the work from Cap. 8.2 on pag. 12 and Cap. 8.3 on pag. 13 first
of all.
The operational reliability of the safety valve must be checked
at regular intervals. We recommend having an annual service
inspection carried out by a qualified specialist company.
The outflow from the safety valve should visibly flow into a
waste water drain.
The installer of the heating system is responsible for checking
whether an additional expansion vessel is required.
Operating the system in a sensible way can provide significant
energy savings. The heating water temperature should be as
low as required during heat pump operation. The planner of the
heating system is responsible for determining the system tem-
perature.
When installing an underfloor heating system, a sensible value
for the maximum flow and return temperature should be set on
the heat pump manager. The position of the temperature sen-
sor is important in this regard.
1.2 Intended use
This device is only intended for use as specified by the manu-
facturer. Any other use beyond that intended by the manufac-
turer is prohibited. This requires the user to abide by the rele-
vant project planning documents. Please refrain from
tampering with or altering the device.
1.3 Legal regulations and guidelines
This heat pump is designed for use in a domestic environment
according to Article 1, Paragraph 2 k) of EU directive 2006/42/
EC (machinery directive) and is thus subject to the require-
ments of EU directive 2014/35/EU (low-voltage directive). It is
thus also intended for use by non-professionals for heating
shops, offices and other similar working environments, agricul-
tural establishments and hotels, guesthouses and other resi-
dential buildings.
The construction and design of the LAW device complies with
all relevant EU directives, DIN and VDE regulations (see CE de-
claration of conformity).
When connecting the LAW device to the power supply, the rel-
evant VDE, EN and IEC standards are to be fulfilled. Any further
connection requirements stipulated by the mains supply net-
work operator must also be observed.
The current valid regulations must be complied with when con-
necting the heating system. The local regulations for the drink-
ing water supply must also be complied with when connecting
the LAW device to the drinking water supply.
This unit can be used by children aged 8 and over and by per-
sons with limited physical, sensory or mental aptitude or lack of
experience and/or knowledge, providing they are supervised or
have been instructed in the safe use of the unit and understand
the associated potential dangers.
Children must not play with the device. Cleaning and user
maintenance must not be carried out by children without su-
pervision.
ATTENTION!
!
!
When operating or maintaining a heat pump, the legal
requirements of the country where the heat pump is operated
apply. Depending on the refrigerant quantity, the heat pump
must be inspected for leaks at regular intervals by a certified
technician, and these inspections must be recorded.
More information can be found in the accompanying log book.
28

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Dimplex LAW 9IMR bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Dimplex LAW 9IMR in de taal/talen: Duits, Engels, Frans als bijlage per email.

De handleiding is 7.79 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info