EN-9 452163.66.36 · FD 9506 www.dimplex.de
English
LA 6TU
11 Device information
1 Type and order code LA 6TU
2Design
2.1 Heat source Air
2.2 Model Universal
2.3 Controller WPM Econ5Plus, wall-mounted
2.4 Thermal energy metering Integrated
2.5 Installation location Outdoors
2.6 Performance levels 1
3 Operating limits
3.1 Heating water flow / return °C up to 60 ± 2K / from 18
3.2 Air °C -20 to +35
4 Flow / sound
4.1 Heating water flow internal pressure differential
according to 14511 m³/h / Pa 1.1 / 9500
Minimum heating water flow m³/h / Pa 0.52 / 2400
4.2 Sound power level according to EN 12102
Normal mode / reduced operation mode1dB(A) 56/52
4.3 Sound pressure level at a distance of 10 m 2
Normal mode / reduced operation mode 1dB(A) 28/24
4.4 Air flow m³/h 2700
5 Dimensions, weight and filling quantities
5.1 Device dimensions 3H x W x L mm 940 x 1350 x 600
5.2 Weight of the transportable unit(s) incl. packaging kg 165
5.3 Device connections for heating system Inches G 1"A
5.4 Refrigerant / total filling weight type / kg R410A / 3.4
5.5 Lubricant / total filling quantity type / litres Polyolester (POE) / 0.7
6 Electrical connection
6.1 Supply voltage / fuse protection 3~/N/PE 400 V (50 Hz) / C 10 A
6.2 Control voltage / fuse protection 1~/N/PE 230 V (50 Hz) / C 13 A
6.3 Degree of protection according to EN 60 529 IP 24
6.4 Starting current limiter no
6.5 Rotary field monitoring no
6.6 Starting current A 27
6.7 Nominal power consumption at A7/W35 /
max. consumption 4kW 1.40/ 2.93
6.8 Nominal current at A7/W35 / cosA / --- 2.88 / 0.7
6.9 Power consumption of compressor protection (per compressor)W -
6.10 Power consumption of fan W 55
7 Complies with the European safety regulations 5