IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
UK
IMPORTANT SAFETY ADVICE
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.
ENSURE THE APPLIANCE IS EARTHED.
Do not use this heater in areas where excessive dust exists.
This heater must not be located immediately above or below a fixed
socket outlet or connection box.
Always disconnect supply before working on the product.
A suitable termination to the fixed wiring of the premises must be
provided adjacent to the final position of the appliance.
This product should be mounted safely to solid wall or ceiling
surfaces only.
This product must not be subjected to water spray or immersion.
Ensure the supply cables are of adequate current carrying capacity
and are protected by a suitable fuse.
If the appliance is mounted in a toilet or washroom, the appliance
should be mounted such that no part of it can be touched by a
person using a fixed bath or shower.
If the appliance is mounted in a toilet or washroom an isolating
switch must be provided outside the washroom adjacent to the
entrance door.
This appliance is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervi-
sion or instruction concerning use of appliance by a person re-
sponsible for their safety.
This heater is not equipped with a device to control the room tem-
perature. Do not use this heater in small rooms when they are
occupied by persons not capable of leaving the room, unless con-
stant supervision is provided.
WARNING: Isolate electrical supply to ALL modular linked units
when carrying out maintenance.
Models
Electrical
The installation of this appliance should be carried out by a competent electrician
and be in accordance with the current IEE wiring regulations.
Dimplex Compact Air Barriers
Models : CAB10E, CAB15E, CAB10W, CAB15W, CAB10A, & CAB15A
DAB10E, DAB15E, DAB10W, DAB15W, DAB10A, & DAB15A
(1)
Fixing Positions
This appliance may be either wall-mounted or fixed to a ceiling - see Fig. 3 for
various fixing positions and ‘Mounting’ sections below, for fixing details. A mini-
mum distance of 100mm is required from top of the appliance to ceiling (see ‘a’ in
Fig. 1) and also the distance between the bottom of the appliance and the top of the
door should be kept to a minimum (see ‘b’ in Fig. 1).
Wall Mounting
Using the wall mounting bracket as a guide (see Fig. 2) mark off hole positions on
the wall (a minimum height of 2.0 metres is required from the floor level to the
bottom of the bracket). Position the bracket such that the air outlet of the installed
air barriers will be as close to the top of the doorway as possible but will remain
unobstructed when installation is complete.
Solid brick or concrete block walls must be drilled and plugged (using a spirit level as
a guide - see ‘x’ in Fig. 2 - to ensure the bracket is level) with rawlplug No. 8 size fibre
inserts. The plug must be located in the solid part of the wall and not just in the
plaster layer.
When fixing to ‘panel’ walls, the wall bracket should be attached to the stud-work
using No. 8 wood screws or by an alternative, equally secure method of fixing.
Once the wall bracket has been fitted, the air barrier can be clipped in place as
shown in Fig. 3a.
Ceiling Mounting
By using threaded inserts in the top panel of the air barrier, attachment to a ceiling
over the product can be achieved using suitable M8 threaded steel rod or similar
supports of sufficient strength - see Fig. 3b.
Electrical connection
All products are fitted with a microprocessor control. Electrical power and control
connections are made as shown in Fig. 6. A suitable local isolating switch must be
provided in the electrical supply circuit with at least 3mm clearance on each pole.
In order to access the electrical connections, remove the outlet grilles (‘x’, and ‘y’
in Fig. 4) by releasing the quick release fasteners and hinging the mouldings as
shown. Remove the bottom panel (‘z’ in Fig. 4) and also remove the pressure plate
(‘w’ in Fig. 4).
All Electric Models - Having removed a ‘knock out’ in the top panel, feed an
appropriate supply cable (see ‘a’ in Fig. 6A) through a suitable cable gland (not
supplied) fitted in the top panel and attach to the terminal block (see ‘b’ in Fig. 6A).
All Water heated and Ambient Models - Having removed a 'knock out'
in the top panel, feed an appropriate supply cable (see 'a' in Fig. 6B) through a
suitable cable gland (not supplied) fitted in the top panel and attach to the PCB (see
'b' in Fig. 6B).
All Models - A suitable cable (CAT5 or equivalent) for a switch panel (kit ref. -
CABC5 for electrically heated models or CABC6 for water heated/ambient models)
can be similarly introduced through the top panel and plugged into the circuit board
as shown in Fig. 6A & 6B. If the unit is to be operated in conjunction with a door
switch, a normally open switch should be wired as per Fig. 7 & 8 as appropriate.
Note: If using a door switch, an additional 2 core (low Voltage) cable is required
between the door switch and the air barriers.
If the unit is to be connected to a Building Energy Management System, connections
are made as per Fig. 7 & 8 as appropriate. Ensure that the air curtain is securely
fastened in position and that the supply cables are firmly clamped before operating
the appliance.
Water connection
Models designed for use in conjunction with a low pressure hot water supply should
be individually connected (in a parallel circuit) to the flow and return pipe-work.
Connections (see ‘a’ in Fig. 5) are: ½ “BSPT (CAB series) and ¾” BSPT (DAB series)
and isolation valves (see ‘b’ in Fig. 5) should be fitted as close to the air barrier
connection points as possible. For commissioning, air bleed valves (see ‘c’ in Fig.
5) are fitted to the coil, which can be accessed by removal of the lower panel and
intake grille - see Fig. 4. The drain (see ‘d’ in Fig. 5) can also be accessed when the
grille and lower panel is removed.
Maximum water supply conditions are 125ºC and 8 bar.
To aid installation, the water coil connections may be moved to either side of the
appliance. By removing the water coil and appropriate knockouts the water coil can
then be re-inserted into the required orientation. This procedure should be carried out
before mounting the appliance.
AMBIENT / COLD STORE
CAB10A n/a 220-240V ~1PN 0.3 15.5 2.7
CAB15A
n/a 220-240V ~1PN 0.5 21.5 2.7
DAB10A
n/a 220-240V ~1PN 1.5 21.5 4.0
DAB15A
n/a 220-240V ~1PN 2.3 27.5 4.0
ELECTRICALLY HEATED
CAB10E 4.5 / 9.0 380-415V ~3PN 14 20.5 2.7
CAB15E 6.75 / 13.5 380-415V ~3PN 20 29 2.7
DAB10E 6.0 / 12.0 380-415V ~3PN 18 26.5 4.0
DAB15E 9.0 / 18.0 380-415V ~3PN 27 35 4.0
WATER HEATED (at 82/71 °C - LPHW)**
CAB10W 9.0 220-240V ~1PN 0.3 17.7 2.7
CAB15W 13.5 220-240V ~1PN 0.5 24.6 2.7
DAB10W 12.0 220-240V ~1PN 1.5 24.7 4.0
DAB15W 18.0 220-240V ~1PN 2.3 31.9 4.0
Model
Heat
output
kW
Electrical
Supply
Electrical
load
A
Weight
Kg
Max
Installed
height
m
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Dimplex DAB15W bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Dimplex DAB15W in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Pools, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 1,67 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info