Connect the red cable to the post marked positive
(+) on the back panel of the inverter. Connect the
red battery clip to the positive (+) terminal of the bat-
tery.
Check that all the connections between battery clips
and terminals are secure
CAUTION:
Loose connections may cause overheated wires and
melted insulation. Check to make sure you have not
reversed the polarity.
Connection to load
The inverter is equipped with a standard AC household
type socket. Plug the cord from the appliance you wish
to use into the socket. Make sure that the combined
load requirement of your equipment does not exceed
the rated watts.
The inverter is engineered to be connected directly
to standard electrical and electronic equipment in the
manner described above. Do not connect the power
inverter to household or recreational vehicle AC distri-
bution wiring .Do not connect the inverter to any AC
load circuit in which the neutral conductor is connected
to earth or the negative of the DC (battery) source.
WARNING:
Never connect to AC distribution wiring.
CAUTION: RECHARGEABLE APPLIANCES
Certain rechargeable devices are designed to be re-
charged by plugging them directly in to a household
socket. This type of device must never be used in the
inverter. The device will damage the inverter. Do not
use the inverter to recharge items that can be plugged
directly into a household socket. This problem does not
occur with the vast majority of battery-operated equip-
ment. Most of these devices use a separate charger
or transformer that is plugged into an AC household
socket. The inverter is easily capable of running most
chargers and transformers.
POSITIONING THE INVERTER
For best operating results, the inverter should be
placed on a at surface such as the ground, car oor
or seat, or another solid surface. The unit is equipped
with a 1 meter-power cord for easy positioning. The in-
verter should only be used in locations that meet the
following criteria.
Dry : do not allow water or liquids to come into con-
tact with the inverter
• Cool: ambient air temperature should be between
-1 ºС non-condensing, and 40 ºС. Do not place the
inverter on or near a heating vent or any equipment,
which is generating heat above room temperature
keep the inverter out of direct sunlight.
Ventilated: keep the area surrounding the inverter clear
to ensure free air circulation around the unit. Do not
place items on or near the unit whilst it is operating. A
fan is helpful if the unit is operating at maximum power
outputs for extended periods of time. If the internal tem-
perature of the inverter exceeds 90 ºС the inverter will
shut down and restart when it has cooled.
The modi ed sine wave produced by the inverter has
an RMS (root mean square) voltage, which is the same
as standard household power. Most AC voltmeters
(analog and digital) are sensitive to the average value
of the waveform rather than the RMS value. They are
calibrated for RMS voltage under the assumption that
waveform measured will be a pure sine wave. Voltme-
ters will not read the RMS voltage of a modi ed sine
wave correctly. The reading will be around 20-30 volts
too low when measuring the inverters output.
INSTALLING THE INVERTER
Power source requirements
The power source for the inverter must provide be-
tween 11 and 15 volts DC and must be able to supply
the necessary current to operate the load. The power
source may be a battery or a well regulated DC power
supply. To obtain a rough estimate of the current in
Amps the power source must deliver simply divide the
power consumption of the load by 10.
Example: If a load is rated at 700 watts AC, the power
source must be able to deliver 700 by 10=70Amps.
CAUTION:
The inverter must be connected only to batteries with a
nominal output voltage of 12 volts. The inverter will not
work if connected to a 6 volts battery and will sustain
permanent damage if connected to a 24 volts battery.
Connecting to the power source
The inverter is equipped with a cigarette lighter plug
and battery clip cables (Inverter of 150 watts output
without battery clip cables) for connection directly to
the power source.
Using the fused cigarette lighter plug
The cigarette lighter plug is suitable for operating the
inverter at power outputs up to 150 watts. The tip of the
plug is positive and the side contact negative. Connect
the inverter to the power source by rmly inserting the
cigarette lighter plug into the cigarette lighter socket.
CAUTION:
Connect directly to battery or power source when
operating above 150watts.
NOTE:
Most vehicle cigarette lighter circuits use fuses rated at
15 to 20 amps or greater. To operate at full output use
the battery clip cable.
Connecting to a power source using provided ca-
bles
If the inverter is to be used for extended periods at
power levels above 150 watts, direct connection to the
power source is required. Use the leads provided to
connect directly to the 12-volt power source using the
following guidelines
Check that the inverter is switched off and no am-
mable fumes are present
Connect the black cable to the post marked nega-
tive (-) on the back panel of the inverter Connect the
black clip to the negative (-) terminal the battery
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Defort DCI-150C bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Defort DCI-150C in de taal/talen: Nederlands, Duits, Engels, Frans, Deens als bijlage per email.

De handleiding is 0,57 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info