16
Technical specification
TECHNICAL SPECIFICATION
Power supply see rating plate
Max. absorbed power
in air conditioning “
Max. absorbed power
when dehumidifying “
Refrigerating capacity* “
Number of fan speeds 2 + silent
Max. air flow 460 m
3
/h
Dimensions of internal unit:
• width 452 mm
• height 800 mm
• depth 455 mm
• weight 33 kg
* Standard conditions:
Room temperature 27°C (80,6°F)
47% relative humidity
Outside temperature 35°C (95°F)
41% relative humidity
OPERATING LIMITS
Room temperature 21 - 35°C
69,8 - 95°F
ELECTRICAL CONNECTION (U.K. ONLY)
A) If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should
be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off
plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a moulded-
on type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nea-
rest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instructins provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with
the following code:
Green and yellow Earth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead may not corre-
spond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The green and yellow wire must be connected to the termi-
nal in the plug marked with the letter E or the earth symbol
or coloured green or green and yellow.
The blue wire must be connected to the terminal marked with
the letter N or coloured black.
The brown wire must be connected to the terminal marked
with the letter L or coloured red.