FFOORR TTHHEE FFIITTTTEERR
As a specialist, you alone are competent to install and connect up De Dietrich appliances.
Our guarantee therefore applies only and exclusively to appliances which have been installed and connected up by
you in accordance with the provisions of current regulations.
Failure to meet this requirement would incur the fitter's liability and release the De Dietrich company from
any liability.
1. Connections
2. Technical characteristics
11
1) CONNECTIONS
Connecting to the mains.
When the cable (H05 RR-F 3x1,5mm
2
, H05 RN-F 3x1,5mm
2
or H05 VV-F 3x1,5mm
2
) requires changing, uns-
crew the screws on the connectors completely before inserting conductors into the appropriate terminals.
The protective conductor must be connected to the terminal on the apparatus.
If you wish to make a permanent connection, put an all-pole circuit breaker with a minimum contact opening of
3mm in the circuit. Under all other conditions, position the oven so that the plug is within easy reaching distance
especially if the oven is built-in.
We cannot be held responsible for any accident resulting from an inexistent or incorrect earth line.
Operating voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ~ 50 Hz
Total power consumption ....................................................................................... 2,03 kW
Energy consumption
-while heating to maintain 200°C for 1 hour ....................................................... 0,70 kWh
Inside dimensions of oven
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,5 cm
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18,2 cm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33,5 cm
Effective volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23,5 litres
This apparatus complies with 73/23/CEE and 89/336/CEE directives.
min.
network voltage connection diameter of fuse
cable
230V~ 50Hz 1 Ph + N 3x1,5 mm2 16 A*
400V 3N~ 50Hz 1 Ph + N 3x1,5 mm2 16 A