Operating voltage...........................................................................230 V ~ 50 Hz
Total power absorbed during cooking....................................................2,591 kW
Nominal power of grill.............................................................................1,50 kW
Energy consumption
-while heating to175°C.........................................................................0,29 kWh
-while heating to maintain 175°C for 1 hour.........................................0,78 kWh
TOTAL...................................................................................................1,07 kWh
Inside dimensions of oven
Width.......................................................................................................42 cm
Height......................................................................................................21 cm
Depth.......................................................................................................37 cm
Effective volume....................................................................................32 litres
FFOORR TTHHEE FFIITTTTEERR
Electrical connections must only be made by an electrical fitter. He must ensure that the appliance is connected up in
accordance with the fitting instructions and local regulations.
Where the appliance is not connected to the mains electricity supply by a plug, an omni polar cutout device (with a contacts
gap of at least 3 mm) must be fitted on the supply side of the connection to meet safety requirements.
NOTE: When power is connected, the electronics of the oven are initialised; this neutralizes the lighting for a few seconds.
The earth wire must be connected to the terminal of the oven.
If the oven is connected to the power supply by a plug, this must remain accessible once the oven has been fitted.
We cannot accept any liability in the event of an accident resulting from non-existent or faulty earthing.
WARNING: Certain inside parts may cause electric shocks, even after the oven has been disconnected. Interventions by non-
qualified personnel are dangerous.
min.
network voltage connection diameter of fuse
cable
230V~ 50Hz 1 Ph + N 1,5 mm
2
16 A*
As a specialist, you alone are competent to install and connect up De Dietrich appliances.
Our guarantee therefore applies only and exclusively to appliances which have been installed and connected up by
you in accordance with the provisions of current regulations.
Failure to meet this requirement would incur the fitter's liability and release the De Dietrich company from
any liability.
1. Connections
2. Technical characteristics
17