RT51/52 + RF
Installation Instructions
User Instructions
Instructions d’installation
Instructions d’utilisateur
Installationsanweisungen
Inbetriebnahme-Instruktion
Instrucciones de instalación
Instrucciones del usuario
Instruktions vejledning
Brugervejleding
Electronic room thermostat with
manual or automatic Day/Night set-back
Installatie handleiding
Instructiesevoor Gebruik
Ïäçãßåò åãêáôÜóôáóçò
Ïäçãßåò ÷ñÞóçò
Instrukcja instalacji
Instrukcja Użytkownika
Montavimo instrukcijos
Informacija Vartotojui
Istruzioni per l’uso
Istruzioni per l’utente
GB
F
D
ES
DK
NL
GR
PL
LT
I
®
Certification Mark
2
Installation Instructions 3-7
User Instructions 8-12
Instructions d’installation 13-17
Instructions d’utilisateur 18-21
Installationsanweisungen 22-26
Inbetriebnahme-Instruktion 27-30
Instrucciones de instalación 31-35
Instrucciones del usuario 36-39
Instruktions vejledning 40-44
Brugervejleding 45-48
Installatie handleiding 49-53
Instructiesevoor Gebruik 54-57
Ïäçãßåò åãêáôÜóôáóçò 58-62
Ïäçãßåò ÷ñÞóçò 63-66
Instrukcja instalacji 67-71
Instrukcja Użytkownika 72-75
Montavimo instrukcijos 76-80
Informacija Vartotojui 81-84
Istruzioni per l’uso 85-89
Istruzioni per l’utente 90-93
GB
F
D
ES
DK
NL
GR
PL
LT
I
Index
3
Installation Instructions
Important note RF products: Ensure that there are no large metal objects, such as boiler cases
or other large appliances, in line of sight between the transmitter and receiver as these will
prevent communication between thermostat and receiver.
Product Speci cation
Please Note:
This product should only be installed by a quali ed
electrician or competent heating installer and should
be in accordance with the current edition of the IEEE
wiring regulations.
Thermostat features RT51/52 RT51/52-RF
Power supply 2 x AA/MN1500/LR alkaline cells
Memory back-up 1 min. for battery change
Switching action of output relay 1 x SPDT, Type 1B N/A
Switch rating of relay contact 3(1)A, 10-230Vac N/A
Transmission frequency (RF model) N/A 433.92MHz
Transmitter range (RF model) N/A 30m max
Temperature range 5-30°C
Dimensions, mm 110 wide, 88 high, 28 deep
Design standard EN60730-2-9 (EN300220 for RF)
Rated impulse voltage 2.5Kv
Ball hardness test 75°C
Control pollution situation Degree 2
Temperature accuracy ±1°C
Installation Instructions
GB
4
Installation
First, remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 140mm to the right, 15mm to the left,
30mm above and 100mm below in order to mount the plug-
in module.
Installation Instructions
GB
5
Prior to mounting the unit should be set in either ON/OFF or
chrono-proportional control mode (see below).
ON/OFF - boilers switches ON when below set temperature
and OFF when above.
Chrono-Proportional - energy saving feature which  res
the boiler at regular intervals to maintain a set temperature,
achieving a constant ambient environment for the user.
Some existing thermostats will have a Neutral wire and/or
Earth wire connected. These are not required by the RT51/52
and must NOT be connected to any RT51/52 terminals. Instead
they should be made electrically safe and coiled in the recess at
the back of the RT51/52.
ON/OFF CHRONO
!
Installation Instructions
GB
6
Thermostat Wiring (not RF models)
TP5000, RT51, RT52 (3061 12/01)
RX1
RX2 & RX3
12
3
4
ELECTRONICS
N
L
COM
ZONE
1 ON
ZONE
1 OFF
A
ELECTRONICS
B
C1
2
345
6
N
L
ZONE
1 ON
ZONE
1 OFF
ZONE
2 ON
ZONE
3 ON
COM
TERMINAL 6
RX3 ONLY
RX Receiver Wiring (RF models only)
N L
NB. For mains voltage operated systems link terminal 2 to mains live supply.
Installation Instructions
GB
7
Commissioning (RF models only)
If the thermostat and the receiver have been supplied together
in a combined pack, the units have been paired in the factory
and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal,
follow steps 1-5 below.
Step 1 RT51/52-RF
Reset the unit by removing the
batteries for 2 minutes, then replace.
Step 2 Press and hold V and +
buttons for 3 seconds (Thermostat now
transmits unique signal continuously
for 5 minutes).
Step 3 RX1
Press and hold buttons PROG and CH1
for 3 seconds until green light  ashes
once.
Step 4 RX2 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps 1-2 and
then press PROG and CH2 on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps 1-2 and then press PROG and
CH2 on RX3.
Stat 3 - wait 5 mins, perform steps 1-2 and then press PROG and
CH3 on RX3.
Step 5 RT51/52-RF
Press Λ or V to select temperature - unit will revert back to operating
mode.
Installation Instructions
GB
8
User Instructions
GB
What is a programmable room thermostat?
... an explanation for householders
A room thermostat simply switches the heating system on and o as
necessary. It works by sensing the air temperature, switching on the
heating when the air temperature falls below the thermostat setting,
and switching it o once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the
room heat up any faster. How quickly the room heats up depends on
the design of the heating system, for example, the size of boiler and
radiators.
Neither does the setting a ect how quickly the room cools down.
Turning a room thermostat to a lower setting will result in the room
being controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has
switched it o .
The way to set and use your room thermostat is to  nd the lowest
temperature setting that you are comfortable with, and then leave it
alone to do its job. The best way to do this is to set the room thermostat
to a low temperature – say 18°C – and then turn it up by one degree
each day until you are comfortable with the temperature. You wont
have to adjust the thermostat further. Any adjustment above this
setting will waste energy and cost yo u more money.
If your heating system is a boiler with radiators, there will usually be
only one room thermostat to control the whole house. But you can have
di erent temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators. If you don’t have TRVs,
you should choose a temperature that is reasonable for the whole
house. If you do have TRVs, you can choose a slightly higher setting to
make sure that even the coldest room is comfortable, then prevent any
overheating in other rooms by adjusting the TRVs.
Room thermostats need a free  ow of air to sense the temperature, so
they must not be covered by curtains or blocked by furniture. Nearby
electric  res, televisions, wall or table lamps may prevent the thermostat
from working properly.
9
Your room thermostat
RT51
The RT51 is a simple to use room thermostat which allows you
to programme a Day and a Night temperature, and to switch
between the two settings simply by pressing 2 buttons.
RT52
The RT52 has the same functionality as the RT51 with the added
bene t of a built-in timer, which will return the thermostat to Day
temperature at a time chosen by you.
Wireless RF versions
Both models are available in wireless versions - RT51-RF and RT52-
RF - which o er exactly the same functions as the hard-wired
models.
Each thermostat communicates with an RX receiver, which can be
located up to 30m away.
Reading your display
User Instructions
22
C
20.0
22
C
20.0
DAY mode
NIGHT mode
Actual room temperature
Required room temperature
Room temperature is lower than
required temperature, therefore
thermostat has switched on and
is calling for heat
User Instructions
GB
10
Before you start
To reset the unit, open the  ap on the
front of the programmer. Remove the
batteries for 2 minutes, then replace.
The display will automatically default to
DAY mode (d shown top left of display)
and show actual temperature in the large
characters and required temperature in
the smaller characters.
DAY temperature
Use the and buttons until the
required DAY temperature is shown.
NIGHT (set-back) temperature
Press and buttons together once to
select NIGHT mode (n shown top left of
display).
Use the and buttons until the
required NIGHT (set-back) temperature
is shown (between 5-30°C or O ).
Setting the DAY & NIGHT temperatures
22
C
20.0
22
C
20.0
All models
User Instructions
GB
11
Pressing the and buttons
together once allows you to toggle
between DAY and NIGHT mode as
required.
Setting the clock
Press PROG button once.
Use and buttons until the correct
TIME is shown.
Press PROG button again.
Use and buttons to select the
time you wish the unit to return to
DAY mode.
RUN Mode
Moving between DAY and NIGHT mode
RT52 / RT52-RF only
Setting the Return to Day Time
i2 00
Press PROG again to return to RUN mode.
The unit will now control your heating at the temperatures you
have set.
User Instructions
GB
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Danfoss RT-RF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Danfoss RT-RF in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Pools, Deens als bijlage per email.

De handleiding is 3,82 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info