1 Introduction
The Danfoss ECtemp Touch is an electronic programmable
timer thermostat used for controlling electrical oor heat-
ing elements. The thermostat is designed for xed instal-
lation only and can be used for both direct heating of the
entire room and for comfort heating of the oor. Among
others, the thermostat has the following features:
A touchscreen display with backlight.
An easy-to-follow menu-driven programming and
operation.
1 Introduction � � � � � � � � � � � � � � � � � � � � � 2
1.1 Technical Specications . . . . . . . . . . . 3
1.2 Safety Instructions . . . . . . . . . . . . . . . 5
2 Mounting Instructions � � � � � � � � � � � � � � � 6
3 Settings � � � � � � � � � � � � � � � � � � � � � � � � 9
3.1 Initial Settings. . . . . . . . . . . . . . . . . . 9
3.2 Forecast . . . . . . . . . . . . . . . . . . . . 13
3.3 Window Open . . . . . . . . . . . . . . . . 15
3.4 Maximum Floor Temperature . . . . . . . 16
4 Symbols � � � � � � � � � � � � � � � � � � � � � � � 18
5 Warranty� � � � � � � � � � � � � � � � � � � � � � � 19
6 Disposal Instruction � � � � � � � � � � � � � � � 19
Table of Contents
Danfoss ECtemp Touch
3Installation Guide
An installation wizard with room/oor type-specic
setup.
Support for multiple frame systems.
Compatible with several 3rd party NTC sensors.
Thermostat settings can be specied before instal-
lation and imported to the thermostat using a
web-generated code, or copied from a thermostat in a
similar installation.
Smart access to thermostat settings after installa-
tion by using a web code interface for easy setup or
remote troubleshooting.
More information on this product can also be found at:
electricheating�danfoss�com
1�1 Technical Specications
Operation voltage 220-240 V~, 50/60 Hz
Standby power consumption Max. 0.40 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Sensing units NTC 6.8 kΩ at 25°C
NTC 10 kΩ at 25°C
NTC 12 kΩ at 25°C
NTC 15 kΩ at 25°C (Default)
NTC 33 kΩ at 25°C
NTC 47 kΩ at 25°C
Danfoss ECtemp Touch
Installation Guide4
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kΩ
18 kΩ
6 kΩ
Control PWM (Pulse Width Modulation)
Ambient temperature 0° to +30°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. oor: 20-35°C (if unrecov-
erable seal is broken then up to
45°C). Min. oor: 10-35°C, only
with combination of room and
oor sensor.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch o the heating if the
sensor is disconnected or short-
circuited
Cable specication max. 1x4 mm
2
or 2x2,5 mm
2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
Danfoss ECtemp Touch
5Installation Guide
IP class 21
Protection class Class II -
Dimensions 85 x 85 x 20-24 mm
(in-wall depth: 22 mm)
Weight 103 g
Electrical safety and Electro-Magnetic Compatibility for
this product is covered by the compliance with the EN/IEC
Standard Automatic electrical controls for household and
similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
1�2 Safety Instructions
Make sure the mains supply to the thermostat is turned o
before installation.
Important: When the thermostat is used to control a oor
heating element in connection with a wooden oor or
similar material, always use a oor sensor and never set the
maximum oor temperature to more than 35°C.
Please also note the following:
The installation of the thermostat must be done by an
authorized and qualied installer according to local
regulations.
Danfoss ECtemp Touch
Installation Guide6
The thermostat must be connected to a power supply
via an all-pole disconnection switch.
Always connect the thermostat to continuous power
supply.
Do not expose the thermostat to moisture, water, dust,
and excessive heat.
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall
(typically 80-170cm.).
The thermostat should not be placed in wet rooms.
Place it in an adjacent room. Always place the ther-
mostat according to local regulation on IP classes.
Do not place the thermostat on the inner side of an
exterior wall.
Always install the thermostat at least 50 cm. from
windows and doors.
Danfoss ECtemp Touch
7Installation Guide
Do not place the thermostat in a way that it will be
exposed to direct sunlight.
Note: A oor sensor enables a more accurate
temperature control and is recommended in all oor
heating applications and mandatory under wooden
oors to reduce the risk of over-heating the oor.
Place the oor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
Equally distant and >2cm from two heating cables.
The conduit should be ush with the oor surface -
countersink the conduit if necessary.
Route the conduit to the connection box.
The bending radius of the conduit must be min 50mm.
Danfoss ECtemp Touch
Installation Guide8
Follow the steps below to mount the thermostat:
1. Open the thermostat:
Important: Do NOT press on the display screen when
removing the front part.
Press your ngers under the side of the front part and
pull toward you:
2. Connect the thermostat according to the connection
diagram.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by
using a separate connector.
Note: Always install the oor sensor in a conduit in the
oor.
N
IP21
T30
Dtouch
Mains
220-240V
50-60 Hz
Maximum
Load 16 (1) A
Sensor
Standby maximum 0.4W
L
L
L
O
A
D
NTC N
L
O
A
D
Danfoss ECtemp Touch
9Installation Guide
3. Mount and reassemble the thermostat.
Fasten the thermostat to a socket or an exterior wall
box by driving the screws through the holes in each
side of the thermostat.
Put the frame on.
Click the display module back in place.
Important: Do NOT press on the display screen when click-
ing the display module back in place.
Initially main supply the thermostat for 15 hours to fully
charge the battery. The current time and day is then kept
for 24 hours if mains supply is o. All other settings are
stored permanently.
3 Settings
3�1 Initial Settings
Initial settings must be specied when the unit is activated
for the rst time:
Danfoss ECtemp Touch
Installation Guide10
1. Use the arrows in the right
side of the screen to go to
your language, and press to
select it. Then press in the
upper right corner to
conrm.
2. Press the hour numbers and
use the < and > arrows to set
the hour. Press to conrm.
3. Press the minutes numbers
and use the < and > arrows
to set the minutes. Press
to conrm. Press again to
go to the SET DATE screen.
4. Press the day, month and
year respectively and set the
date using the < and >
arrows and pressing to
conrm. When the date is
correct, press to conrm
on the SET DATE screen.
Danfoss ECtemp Touch
11Installation Guide
5. If you have already made
the installation setup online,
press ENTER CODE and go
directly to Step 13 now. Oth-
erwise press
SETUP WIZARD
and go to Step 6.
6. On the SETUP information
screen, press to start.
7. Use the < and > arrows to
select whether only a oor
sensor or a combination of
room and oor sensors
should be used. Press to
conrm.
Note: A “room only” option may also be available. For details, see
the “Maximum Floor Temperature” section.
Danfoss ECtemp Touch
Installation Guide12
8. Use the < and > arrows to
select the installed oor
sensor type. (Measured
resistance and correspond-
ing temperature are shown
in brackets). Press to
conrm.
9. Use the < and > arrows to
select the ooring type. Press
to conrm.
10. Use the < and > arrows to
select the room type. Press
to conrm.
11. Use the < and > arrows to
select the approximate load
of the heating element. If an
external relay is used or the
installed output is unknown,
select the “– –” option. Press
to conrm.
Danfoss ECtemp Touch
13Installation Guide
12. Use the < and > arrows to
select whether the timer
should be activated or not.
Press to conrm and end
the initial thermostat setup.
Skip Step 13.
13. Enter your web-generated
code. Then press to end
the initial thermostat setup.
If no check mark ( )
appears, the hexacode is
incorrect.
3�2 Forecast
The forecast feature is used when you switch between
economy temperature and comfort temperature. If forecast
is turned on, heating will start so that the requested tem-
perature is reached at the specied time.
For example, if your comfort temperature is set to 22°C and
the comfort period starts at 6.00 oclock am, heating will
start before 6 oclock so that your room temperature will be
22°C at 6 oclock. If forecast is turned o, heating will not
start until 6 o’clock and it will take a while to reach a room
temperature of 22°C.
The forecast feature also optimises heating stop when switch-
ing from comfort temperature to economy temperature.
Danfoss ECtemp Touch
Installation Guide14
How to turn the forecast feature on and o
1. Touch the thermostat display
to activate it, then press menu.
2. Press SETTINGS in the bottom
right corner of the menu. Then
press OPTIONS.
3. Press FORECAST. Then press
ON to optimise heating start/
stop or OFF to simply let the
heating start/stop at the speci-
ed time. Press to conrm.
To return to the normal temperature display, press the back
arrow in the upper left corner of the screen until you get to
the main menu, then press .
Danfoss ECtemp Touch
15Installation Guide
3�3 Window Open
How to turn “window open detection” on or o
1. Touch the thermostat display
to activate it, then press
menu.
2. Press SETTINGS in the bottom
right corner of the menu. Then
press OPTIONS.
3. Press WINDOW OPEN. Then
press ON to temporarily turn
o heating in case of a sudden
temperature drop in the room
or OFF to let the thermostat
heat during sudden tempera-
ture drops in the room. Press
to conrm.
To return to the normal temperature display, press the back
arrow in the upper left corner of the screen until you get to
the main menu, then press .
Danfoss ECtemp Touch
Installation Guide16
3�4 Maximum Floor Temperature
How to set the maximum oor temperature
1. Touch the thermostat display
to activate it, then press
menu.
2. Press SETTINGS in the bottom
right corner of the menu. Then
press INSTALLATION and
MANUAL SETUP.
3. Press MAX� FLOOR. Then use
the < and > arrows to set the
allowed maximum oor
temperature.
Press to conrm.
To return to the normal temperature display, press the back
arrow in the upper left corner of the screen until you get to
the main menu, then press .
Danfoss ECtemp Touch
17Installation Guide
If you break the small plastic seal
on the back of the display mod-
ule, e.g. using a screwdriver, it will
be possible to set the maximum
oor temperature up to 45°C.
Furthermore, it will be possible to
use only a room sensor. However,
this option is not recommendable due to an increased risk
of overheating the oor.
Important: When the thermostat is used to control a oor
heating element in connection with a wooden oor or
similar material, always use a oor sensor and never set the
maximum oor temperature to more than 35°C.
Note: Please contact the oor supplier before changing the
maximum oor temperature and be aware of the following:
The oor temperature is measured where the sensor
is placed.
The temperature of the bottom of a wooden oor can
be up to 10 degrees higher than the top.
Floor manufactures often specify the max. tempera-
ture on the top surface of the oor.
Danfoss ECtemp Touch
Installation Guide18
Thermal
resistance
[m
2
K/W]
Examples of
ooring
Details Approximate
setting for
25˚C oor
temperature
0.05 8 mm HDF based
laminate
> 800 kg/m
3
28˚C
0.10 14 mm beech
parquet
650 - 800
kg/m
3
31˚C
0.13 22 mm solid oak
plank
> 800 kg/m
3
32˚C
< 0.17 Max. carpet thick-
ness suitable for
oor heating
acc. to EN
1307
34˚C
0.18 22 mm solid r
planks
450 - 650
kg/m
3
35˚C
4 Symbols
The following symbols may appear in the upper left corner
of the temperature display:
Symbol What it means
The thermostat is in manual mode, i.e. the timer
function is o. The timer lets you automatically
switch between economy and comfort tempera-
tures according to a predened schedule.
Danfoss ECtemp Touch
19Installation Guide
Symbol What it means
An away period has been planned. On the date of
departure, the away period starts at 00:00 and the
specied away temperature will be maintained 24
hours a day until the date of return at 00:00. At this
time the normal temperature settings will resume.
An error has occurred. If you press the warning
symbol, more information on the error will appear.
5 Warranty
6 Disposal Instruction
Danfoss ECtemp Touch
Installation Guide20
Danfoss ECtemp Touch
21Installation Guide
Danfoss ECtemp Touch
Installation Guide22
Danfoss ECtemp Touch
Danfoss A/S
Electric Heating Systems
Ulvehavevej 61
7100 Vejle
Denmark
Phone: +45 7488 8500
Fax: +45 7488 8501
http://electricheating.danfoss.com/
Produced by Danfoss © 04/201508091366 & VIIOH102
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other
printed material. Danfoss reserves the right to alter its products without notice. This also applies
to products already on order provided that such alterations can be made without subsequential
changes being necessary in specications already agreed. All trademarks in this material are
property of the respective companies. Danfoss and the Danfoss logotype are trademarks of
Danfoss A/S. All rights reserved.
ECtemp Touch - Pure White
088L0122 EN
Design Frame
Intelligent Timer Ther-
mostat
Floor / Room Sensor
220-240V~
50-60Hz
0°C to +30°C
16A/3680W@230V~
IP 21
Product documentation
21
,7
Designed in Denmark for Danfoss A/S
*08091366*
5 7 0 3 4 6 6 2 3 5 4 8 5
dMA
4

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Danfoss-ECtemp-Touch
  • Wat betekenen de concentrische cirkels op het (begin)scherm vaan de thermostaat? Gesteld op 3-8-2023 om 15:19

    Reageer op deze vraag Misbruik melden
  • We hebben een Danfoss ECtemp Touch. Sinds een dag is het in de ruimte 35 gr terwijl de thermostaat op 20 gr staat. We hebben glasverwarming en het ene raam is koud en het andere gloeiend heet. Weet iemand of het aan de thermostaat kan liggen? Gesteld op 30-12-2021 om 10:56

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Danfoss ECtemp Touch bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Danfoss ECtemp Touch in de taal/talen: Engels als bijlage per email.

De handleiding is 1,73 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info