Electronic Intelligent Timer
Thermostat
Installation Guide
electricheating.danfoss.com
Danfoss ECtemp Next Plus
Installation Guide2
1 Introduction � � � � � � � � � � � � � � � � � � � � � 2
1.1 Technical Specications . . . . . . . . . . . 3
1.2 Safety Instructions . . . . . . . . . . . . . . . 5
2 Mounting Instructions � � � � � � � � � � � � � � � 5
3 Symbols � � � � � � � � � � � � � � � � � � � � � � � � 8
4 Settings � � � � � � � � � � � � � � � � � � � � � � � 10
4.1 Power ON/OFF . . . . . . . . . . . . . . . . 11
4.2 Initial Settings . . . . . . . . . . . . . . . . 11
4.3 Advanced Programmable Timer . . . . . 13
4.4 Temperature Setting . . . . . . . . . . . . 15
4.5 Timer Setting . . . . . . . . . . . . . . . . . 16
4.6 Safety Lock. . . . . . . . . . . . . . . . . . . 17
4.7 Away Mode . . . . . . . . . . . . . . . . . . 17
4.8 Present Floor Temperature. . . . . . . . . 17
4.9 Change to Room control only . . . . . . 18
4.10 Extending Maximum oor temperature
limitation to 45°C . . . . . . . . . . . . . . 18
4.11 Table for 4.9 Change to Room control
only and 4.10 Extending Maximum Floor
temperature limitations to 45°C . . . . . 19
5 Error Codes � � � � � � � � � � � � � � � � � � � � � 20
6 Warranty� � � � � � � � � � � � � � � � � � � � � � � 21
7 Disposal Instruction � � � � � � � � � � � � � � � 21
Table of Contents
Danfoss ECtemp Next Plus
3Installation Guide
1 Introduction
The Danfoss ECtemp Next Plus is an electronic program-
mable timer thermostat used for controlling electrical oor
heating elements. The thermostat is designed for xed
installation only and can be used for both direct heating of
the entire room and for comfort heating of the oor.
More information on this product can also be found at:
electricheating�danfoss�com
1�1 Technical Specications
Operation voltage 85-250V~, 50/60 Hz
Standby power consumption 0,4 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Floor sensor Floor Sensor NTC 10 kΩ
at 25°C
Room Sensor NTC 10 kΩ
at 25°C
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kΩ
18 kΩ
6 kΩ
Control Hysteresis ± 1.0° C
Danfoss ECtemp Next Plus
Installation Guide4
Ambient temperature -10°C to +60°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: Max. 35°C
is default.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch o the heating if the
sensor is disconnected or short-
circuited
Cable specication max. 1x4 mm
2
or 2x2,5 mm
2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
IP class 30
Protection class Class II -
Dimensions 86 x 86 x 16/40.5 mm
(in-wall depth: 24.5 mm)
Weight 103 g
Electrical safety and Electro-Magnetic Compatibility for
this product is covered by the compliance with the EN/IEC
Danfoss ECtemp Next Plus
5Installation Guide
Standard Automatic electrical controls for household and
similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
1�2 Safety Instructions
Make sure the mains supply to the thermostat is turned o
before installation.
Important: When the thermostat is used to control a oor
heating element in connection with a wooden oor or
similar material, always use a oor sensor and never set the
maximum oor temperature to more than 35°C.
Please also note the following:
The installation of the thermostat must be done by an
authorized and qualied installer according to local
regulations.
The thermostat must be connected to a power supply
via an all-pole disconnection switch.
Always connect the thermostat to continuous power
supply.
Do not expose the thermostat to moisture, water, dust,
and excessive heat.
Danfoss ECtemp Next Plus
Installation Guide6
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall
(typically 80-170cm.).
The thermostat should not be placed in wet rooms.
Place it in an adjacent room and use oor sensor
only. Always place the thermostat according to local
regulation on IP classes and use oor sensor only.
Do not place the thermostat on the inner side of an
exterior wall.
Always install the thermostat at least 50 cm. from
windows and doors.
Do not place the thermostat in a way that it will be
exposed to direct sunlight.
Note: A oor sensor enables a more accurate
temperature control and is recommended in all oor
heating applications and mandatory under wooden
oors to reduce the risk of over-heating the oor.
Danfoss ECtemp Next Plus
7Installation Guide
Place the oor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
Equally distant and >2cm from two heating cables.
The conduit should be ush with the oor surface -
countersink the conduit if necessary.
Route the conduit to the connection box.
The bending radius of the conduit must be min 50mm.
Connect the thermostat according to the connection
diagram.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using a
separate connector.
Note: Always install the oor sensor in a conduit in the
oor.
Danfoss ECtemp Next Plus
Installation Guide8
3 Symbols
The following symbols appears in the display:
Symbols Function description Symbols Function description
Room temperature Away mode
Floor temperature Child safety lock
Temperature indication Power ON/OFF
SET
Set temperature
Timer and program
operation
Floor heating, Active
M
Mode change/check
oor temp./child
safety lock/parameters
setting
Frost protection, Active
< >
Up/down selectors
Power ON/OFF
SET
M
<
>
<
<
M
Danfoss ECtemp Next Plus
9Installation Guide
4 Settings
4�1 Power ON/OFF
Switch thermostat ON/OFF by pressing button on top of
thermostat.
4�2 Initial Settings
Initial settings must be specied when the unit is activated
for the rst time:
Press M button for 6 seconds to enter the parameter setting
mode.
The upper digits indicate the parameter number.
Press M for parameter selection.
Press < or > to set the parameter range.
Complete all adjustments.
Press to exit ECtemp Next Plus settings, which is available
for this purpose.
To exit ECtemp Next settings automatic wait approx. 30
seconds.
Danfoss ECtemp Next Plus
Installation Guide10
The digits indicate the set value as follows:
No� Parameter settings Settings range Default
P01 Working mode 01: Manual
02: Advanced Program-
mable Timer
02
P02 Temperature control
mode
01: Room and oor temp;
02: Only oor temp.;
03: Only room temp.*
01
P03 Maximum oor
temperature
20-30˚C (only for 01 in
P02)**
35˚C
P04 Frost protection 01: Enable; 02: Disable 01
P05 Frost protection
setpoint
5-9˚C 5˚C
P06 Timer display option 01: 24h; 02 12h 01
P07 Room temp. display
option at shutdown
01: No display surrent
temp.;
02: Display current temp.
01
* It will be possible to use only a room sensor. However, this option is not recom-
mendable due to an increased risk of overheating the oor. See 4.9 Change to
Room control only
** P03 appears on relevant temperature control mode. See 4.10 Extending
Maximum oor temperature limitations to 45°C
4�3 Advanced Programmable Timer
The Advanced Programmable Timer mode enables the set-
ting of a timer-controlled program for automatic comfort
Danfoss ECtemp Touch
Produced by Danfoss © 04/201608096226 & VIIOK202
Danfoss A/S
Electric Heating Systems
Ulvehavevej 61
7100 Vejle
Denmark
Phone: +45 7488 8500
Fax: +45 7488 8501
http://electricheating.danfoss.com/
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other
printed material. Danfoss reserves the right to alter its products without notice. This also applies
to products already on order provided that such alterations can be made without subsequential
changes being necessary in specications already agreed. All trademarks in this material are
property of the respective companies. Danfoss and the Danfoss logotype are trademarks of
Danfoss A/S. All rights reserved.
23

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Danfoss ECtemp Next Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Danfoss ECtemp Next Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 1,01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info