730472
3
Verklein
Vergroot
Pagina terug
1/34
Pagina verder
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
FVXS25KV1A
FVXS35KV1A
FVXS50KV1A
FVXS35LV1A
00_CV_3P278434-1A.fm Page 1 Friday, July 22, 2011 4:19 PM
1
CONTENTS
READ BEFORE OPERATION
Safety Precautions......................................... 2
Names of Parts .............................................. 4
Preparation before Operation......................... 7
OPERATION
AUTO · DRY · COOL · HEAT · FAN
Operation ..................................................... 10
Adjusting the Airflow Direction ..................... 12
POWERFUL Operation................................ 14
OUTDOOR UNIT QUIET Operation............. 15
ECONO Operation ....................................... 16
TIMER Operation ......................................... 17
WEEKLY TIMER Operation ......................... 19
Note for Multi System................................... 24
CARE
Care and Cleaning ....................................... 26
TROUBLESHOOTING
Troubleshooting ........................................... 29
01_EN_3P278434-1A.fm Page 1 Tuesday, October 4, 2011 5:54 PM
2
READ BEFORE OPERATION
Safety Precautions
Keep this manual where the operator can easily find it.
Read the precautions in this manual carefully before operating the unit.
The precautions described herein are classified as WARNING and CAUTION. They both contain
important information regarding safety. Be sure to observe all precautions without fail.
After reading, keep this manual in a convenient place so that you can refer to it whenever neces-
sary. If the equipment is transferred to a new user, be sure also to hand over the manual.
WARNING
In order to avoid fire, explosion or injury, do not operate the unit when harmful, among
which flammable or corrosive gases, are detected near the unit.
Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to
air that is too cool or too warm can be harmful to your physical condition and health.
Do not place objects, including rods, your fingers, etc., in the air inlet or outlet. Product malfunctioning,
product or injury damage may result due to contact with the air conditioner's high-speed fan blades.
Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result
in water leakage, electric shocks or fire hazards.
Do not use flammable spray near the air conditioner, or otherwise fire may result.
Beware of fire in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e.
not generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for
assistance. The refrigerant within the air conditioner is safe and normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of nox-
ious gas. Do not longer use the air conditioner until a qualified service person confirms that the leakage has been repaired.
Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric
shocks or fire hazards. Please contact your local dealer or qualified personnel for installation and maintenance work.
When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your
local dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards.
Be sure to install an earth leakage breaker. Failure to install the earth leakage breaker may result in electric shocks or fire.
Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or tele-
phone earth lead. Imperfect earthing may result in electric shocks.
CAUTION
Do not use the air conditioner for purposes other than those for which it is intended. Do not use
the air conditioner for cooling precision instruments, food, plants, animals or works of art as this
may adversely affect the performance, quality and/or longevity of the object concerned.
Do not expose plants or animals directly to airflow from the unit as this may cause adverse effects.
WARNING
Failure to follow these instructions properly may
result in personal injury or loss of life.
CAUTION
Failure to observe these instructions properly may
result in property damage or personal injury, which may
be serious depending on the circumstances.
Never attempt. Be sure to follow the instructions.
Be sure to establish an earth connection.
Never wet the air conditioner nor the remote
controller with water.
Never touch the air conditioner nor the
remote controller with wet hands.
01_EN_3P278434-1A.fm Page 2 Tuesday, October 4, 2011 5:54 PM
3
Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner.
Do not block air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.
Do not sit or place objects on the outdoor unit. Falling yourself or falling objects could cause injury.
Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units.
Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain
blockage may cause dripping, resulting in fouling or failure of the object concerned.
After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged
condition, the unit may fall and cause injury.
To avoid injury, do not touch the air inlet or aluminum fins of the unit.
The appliance is not intended for use by unattended young children or infirm persons. Impairment of
bodily functions and harm to health may result.
To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such
as a burner is used together with the air conditioner.
Before cleaning, be sure to stop unit operation, turn the breaker off or remove the power
cord. Otherwise, an electric shock and injury may result.
Only connect the air conditioner to the specified power supply circuit. Power supplies other than the
one specified may result in electric shocks, overheating and fires.
Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture etc.
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumu-
late around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit,
such animals can cause malfunctions, smoke or fire when making contact with electrical parts.
Do not place objects around the indoor unit.
Doing so may have an adverse influence on the performance, product quality, and life of the air conditioner.
This appliance is not intended to be used by persons with reduced physical, sensory or mental
capabilities, or with lack of operation knowledge, unless they have been given supervision or
instruction concerning the appliance use by person responsible for their safety.
Keep out of children's reach to ensure that they do not play with the appliance.
To avoid electric shocks, do not operate with wet hands.
Do not wash the air conditioner with water, as this may result in electric shocks or fire.
Do not place water containers (vases etc.) above the unit, as this may result in electric shocks
or fire hazards.
To install the air conditioner in the following types of environments, consult the dealer.
Places with an oily ambient or where steam or soot occurs.
Salty environment such as coastal areas.
Places where sulfide gas occurs such as hot springs.
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.
For installation, choose a place as described below.
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
Relocating the air conditioner requires specialized knowledge and skills. Please consult the
dealer if relocation is necessary for moving or remodeling.
Installation site.
Consider nuisance to your neighbours from noises.
Electrical work.
System relocation.
01_EN_3P278434-1A.fm Page 3 Tuesday, October 4, 2011 5:54 PM
4
Names of Parts
Indoor Unit
Opening the Front Panel
How to open the front panel: (page 26.)
CAUTION
Before opening the front panel, be sure to stop the operation and turn the breaker off.
Do not touch the aluminum fins on the inside of the indoor unit, as it may result in injury.
12
6
512
2
4
7
8
3
9
13
10
11
14
15
Air outlet selection switch
This setting blows air from upper outlet only.
This setting automatically decides a blow
pattern depending on mode and conditions.
• The unit is shipped from the
factory with this setting.
• This setting is
recommended.
01_EN_3P278434-1A.fm Page 4 Tuesday, October 4, 2011 5:54 PM
5
Outdoor Unit
Indoor Unit
1. Titanium apatite photocatalytic
air-purifying filter:
These filters are attached to the inside of
the air filters.
2. Air outlet
3. Display
4. Front panel
5. Louvers (vertical blades):
(page 12.)
The louvers are inside of the air outlet.
6. Air inlet
7. Air filter
8. Flap (horizontal blade):
(page 12.)
9. OPERATION lamp (green)
10. TIMER lamp (yellow): (page 17.)
11. Indoor Unit ON/OFF switch:
Push this switch once to start operation.
Push once again to stop it.
The operation mode refers to the following
table.
This switch is useful when the remote
controller is missing.
12. Model name plate
13. Signal receiver:
It receives signals from the remote
controller.
When the unit receives a signal, you will
hear a short beep.
Operation start ........ beep-beep
Settings changed ..... beep
Operation stop.......... long beep
14. Air outlet selection switch:
(page 13.)
15. Room temperature sensor:
It senses the air temperature around the unit.
Outdoor Unit
16. Air inlet: (Back and side)
17. Refrigerant piping and inter-unit wiring
18. Drain hose
19. Earth terminal:
It is inside of this cover.
20. Air outlet
21. Outdoor temperature sensor (back)
22. Model name plate
Appearance of the outdoor unit may differ from some models.
17
18
22
19
20
16
21
Mode
Temperature
setting
Airflow rate
COOL
22°C
AUTO
AUTO
25°C
AUTO
01_EN_3P278434-1A.fm Page 5 Tuesday, October 4, 2011 5:54 PM
6
Names of Parts
Remote Controller
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings.
(In this illustration, each section is shown
with all its displays on for the purpose of
explanation.)
3. FAN setting button:
It selects the airflow rate setting.
4. POWERFUL button:
POWERFUL operation (page 14.)
5. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.
6. TEMPERATURE adjustment buttons:
It changes the temperature setting.
7. MODE selector button:
It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN) (page 10.)
8. QUIET button:
OUTDOOR UNIT QUIET operation (page 15.)
9. ECONO button:
ECONO operation (page 16.)
10. SWING button:
Adjusting the airflow direction (page 12.)
11. WEEKLY/PROGRAM/COPY/BACK/NEXT
button:
WEEKLY TIMER operation (page 19.)
12. SELECT button:
It changes the ON/OFF TIMER and
WEEKLY TIMER settings. (page 17, 19.)
13. OFF TIMER button: (page 17.)
14. ON TIMER button: (page 18.)
15. TIMER CANCEL button:
It cancels the timer setting. (page 17, 18.)
It cannot be used for the WEEKLY TIMER
operation.
16. CLOCK button: (page 8.)
1
5
6
2
3
4
<ARC452A2>
7
8
11
12
13
15
<Open the lid>
9
10
14
16
01_EN_3P278434-1A.fm Page 6 Tuesday, October 4, 2011 5:54 PM
7
Preparation before Operation
To set the batteries
1. Slide the front cover to take it off.
2. Set two dry batteries AAA.LR03 (alkaline).
3. Set the front cover as before.
To operate the remote controller
To use the remote controller, aim the transmitter at the indoor
unit. If there is anything to block signals between the unit and
the remote controller, such as a curtain, the unit will not
operate.
Do not drop the remote controller. Do not get it wet.
The maximum distance for communication is about 7m.
To fix the remote controller holder
on the wall
1. Choose a place from where the signals
reach the unit.
2. Fix the holder to a wall, a pillar, etc. with the
screws supplied with the holder.
3. Place the remote controller in the remote
controller holder.
NOTE
Notes on batteries
When replacing the batteries, use batteries of the same type, and replace both old batteries together.
When the system is not used for a long time, take the batteries out.
The batteries will last for approximately 1 year. If the remote controller display begins to
fade and the degradation of reception performance occurs within a year, however, replace
both batteries with new, size AAA.LR03 (alkaline).
The attached batteries are provided for the initial use of the system.
The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
Notes on remote controller
Never expose the remote controller to direct sunlight.
Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth.
Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such
as inverter-type lamps) is in the room. Consult the shop if that is the case.
If the remote controller signals happen to operate another appliance, move that appliance
to somewhere else, or consult the shop.
2
3
1
Position
+
and
– correctly!
Receiver
Remote
controller
holder
Set.
To remove, pull it
upwards.
01_EN_3P278434-1A.fm Page 7 Tuesday, October 4, 2011 5:54 PM
8
Preparation before Operation
To set the clock
1. Press “CLOCK button”.
” is displayed.
” and “ ” blink.
2. Press “SELECT button” to set
the current day of the week.
3. Press “CLOCK button”.
” blinks.
4. Press “SELECT button” to set
the clock to the present time.
Holding down “ ” or “ ” button
rapidly increases or decreases the time
display.
5. Press “CLOCK button”.
Point the remote controller at the indoor
unit when pushing the buttons when
setting the indoor unit’s internal clock.
” blinks.
NOTE
If the indoor unit’s internal clock is not set to the correct time, ON/OFF TIMER and
WEEKLY TIMER will not operate punctually.
1, 3, 5
2, 4
01_EN_3P278434-1A.fm Page 8 Tuesday, October 4, 2011 5:54 PM
9
Turn the breaker on
After the power is turned on, the flap of the indoor unit opens and closes once to set the
reference position.
NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy.
Clean them once in about every two weeks.
Please note
The air conditioner always consumes a small amount of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
Use the air conditioner in the following conditions.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
Recommended temperature setting
For cooling:26-28°C
For heating:20-24°C
Mode Operating conditions If operation is continued out of this range
COOL
Outdoor temperature:
3MXS–5-46°C
RMXS–5-46°C
4MXS–10-46°C
RXS10-46°C
Indoor temperature: 18-32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of
the outdoor unit only.)
Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature:
3/4MXS–15-24°C
RMXS–15-24°C
RXS–15-24°C
Indoor temperature: 10-30°C
A safety device may work to stop the operation.
DRY
Outdoor temperature:
3MXS–5-46°C
RMXS–5-46°C
4MXS–10-46°C
RXS10-46°C
Indoor temperature: 18-32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
01_EN_3P278434-1A.fm Page 9 Tuesday, October 4, 2011 5:54 PM
10
OPERATION
AUTO · DRY · COOL · HEAT · FAN Operation
The air conditioner operates with the operation
mode of your choice.
From the next time on, the air conditioner will
operate with the same operation mode.
To start operation
1. Press “MODE selector button”
and select an operation mode.
Each pressing of the button advances
the mode setting in sequence.
:AUTO
:DRY
: COOL
:HEAT
:FAN
2. Press “ON/OFF button”.
The OPERATION lamp lights green.
To stop operation
3. Press “ON/OFF button” again.
The OPERATION lamp goes off.
To change the temperature setting
4. Press “TEMPERATURE adjustment button”.
DRY or FAN operation AUTO or COOL or HEAT operation
The temperature setting is not variable.
Press “ ” to raise the temperature and press
” to lower the temperature.
Set to the temperature you like.
1
2, 3
4
01_EN_3P278434-1A.fm Page 10 Tuesday, October 4, 2011 5:54 PM
11
To change the airflow rate setting
5. Press “FAN setting button”.
Indoor unit quiet operation
When the airflow is set to “ ”, the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
The unit might lose capacity when the airflow rate is set to a weak level.
NOTE
DRY operation AUTO or COOL or HEAT or FAN operation
The airflow rate setting is not variable.
Five levels of airflow rate setting from “ ” to “
plus “ ” “ ” are available.
Notes on HEAT operation
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the
heating capacity becomes smaller in lower outdoor temperatures. If the heating effect is
insufficient, it is recommended to use another heating appliance in combination with the air
conditioner.
The heat pump system heats the room by circulating hot air around all parts of the room.
After the start of heating operation, it takes some time before the room gets warmer.
In heating operation, frost may occur on the outdoor unit and lower the heating capacity. In
that case, the system switches into defrosting operation to take away the frost.
During defrosting operation, hot air does not flow out of indoor unit.
Note on COOL operation
This air conditioner cools the room by releasing the heat in the room outside.
Therefore, the cooling performance of the air conditioner may be degraded if the outdoor
temperature is high.
Note on DRY operation
The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and airflow late, so manual
adjustment of these functions is unavailable.
Notes on AUTO operation
In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT)
based on the room and outside temperatures and starts the operation.
The system automatically reselects setting at a regular interval to bring the room
temperature to user-setting level.
If you do not like AUTO operation, manually change the set temperature.
Note on airflow rate setting
At smaller airflow rates, the cooling (heating) effect is also smaller.
01_EN_3P278434-1A.fm Page 11 Tuesday, October 4, 2011 5:54 PM
12
Adjusting the Airflow Direction
You can adjust the airflow direction to increase
your comfort.
To adjust the flap
(horizontal blade)
1. Press “SWING button”.
” is displayed on the LCD and the
flap will begin to swing.
2. When the flap has reached the
desired position, press
“SWING button” once more.
The flap will stop moving.
” disappears from the LCD.
To adjust the louvers
(vertical blades)
Hold the knob and move the louvers.
(You will find a knob on the left-side and the right-
side blades.)
Notes on flap and louvers angle
Unless “SWING” is selected, you should set the
flap at a near-horizontal angle in HEAT operation
and at a upward position in COOL or DRY
operation to obtain the best performance.
ATTENTION
When adjusting the flap by hand, turn off the unit,
and use the remote controller to restart the unit.
Be careful when adjusting the louvers. Inside the
air outlet, a fan is rotating at a high speed.
1, 2
COOL/
DRY
HEAT
01_EN_3P278434-1A.fm Page 12 Tuesday, October 4, 2011 5:54 PM
13
Airflow selection
Make airflow selection according to what suits you.
When setting the airflow selection switch to .
Air conditioner automatically decides the appropriate blowing pattern depending on the operating
mode/situation.
During DRY operation, so that cold air does not come into direct contact with people, air is blown
upper air outlet.
When setting the air outlet selection switch to .
Regardless of the operating mode or situation, air blows from the upper air outlet.
Use this switch when you do not want air coming out of the lower air outlet. (While sleeping etc.)
CAUTION
Operating mode Situation Blowing pattern
COOL operation
When the room has become fully
cool, or when one hour has
passed since turning on the air
conditioner.
So that air does not come into
direct contact with people, air is
blown upper air outlet, room tem-
perature is equalized.
At start of operation or other
times when the room is not fully
cooled.
Air is blown from the upper and
lower air outlets for high speed
cooling during COOL operation,
and for filling the room with warm
air during HEAT operation.
HEAT operation
At times other than below.
(Normal time.)
At start or when air temperature
is low.
So that air does not come into
direct contact with people. Air is
blown upper air outlet.
Do not try to adjust the flap by hand.
When adjusting by hand, the mechanism may not operate properly or condensation may drip
from air outlets.
01_EN_3P278434-1A.fm Page 13 Tuesday, October 4, 2011 5:54 PM
14
POWERFUL Operation
POWERFUL operation quickly maximizes the
cooling (heating) effect in any operation mode.
You can get the maximum capacity.
To start POWERFUL
operation
1. Press “POWERFUL button”.
POWERFUL operation ends in
20minutes. Then the system
automatically operates again with the
previous settings which were used
before POWERFUL operation.
” is displayed on the LCD.
When using POWERFUL operation,
there are some functions which are
not available.
To cancel POWERFUL
operation
2. Press “POWERFUL button”
again.
” disappears from the LCD.
NOTE
Notes on POWERFUL operation
POWERFUL operation cannot be used together with ECONO or QUIET operation.
Priority is given to the function of whichever button is pressed last.
POWERFUL operation can only be set when the unit is running. Pressing the operation
stop button causes the settings to be canceled, and the “ ” disappears from the LCD.
POWERFUL operation will not increase the capacity of the air conditioner if the air
conditioner is already in operation with its maximum capacity demonstrated.
In COOL, HEAT and AUTO operation
To maximize the cooling (heating) effect, the capacity of outdoor unit is increased and the
airflow rate is fixed to the maximum setting.
The temperature and airflow settings are not variable.
In DRY operation
The temperature setting is lowered by 2.5°C and the airflow rate is slightly increased.
In FAN operation
The airflow rate is fixed to the maximum setting.
When using priority-room setting
See note for multi system. (page 24.)
1, 2
01_EN_3P278434-1A.fm Page 14 Tuesday, October 4, 2011 5:54 PM
15
OUTDOOR UNIT QUIET Operation
OUTDOOR UNIT QUIET operation lowers the
noise level of the outdoor unit by changing the
frequency and fan speed on the outdoor unit.
This function is convenient during night.
To start OUTDOOR
UNIT QUIET operation
1. Press “QUIET button”.
” is displayed on the LCD.
To cancel OUTDOOR
UNIT QUIET operation
2. Press “QUIET button” again.
” disappears from the LCD.
NOTE
Notes on OUTDOOR UNIT QUIET operation
If using a multi system, the OUTDOOR UNIT QUIET operation will work only when this
function is set on all operated indoor units.
However, if using priority-room setting, see note for multi system. (page 24.)
This function is available in COOL, HEAT, and AUTO operation.
(This is not available in FAN and DRY operation.)
POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the
same time.
Priority is given to the function of whichever button is pressed last.
If operation is stopped using the remote controller or the indoor unit ON/OFF switch when
using OUTDOOR UNIT QUIET operation, “ ” will remain on the remote controller
display.
OUTDOOR UNIT QUIET operation will drop neither the frequency nor fan speed if the
frequency and fan speed have been already dropped low enough.
1, 2
01_EN_3P278434-1A.fm Page 15 Tuesday, October 4, 2011 5:54 PM
16
ECONO Operation
ECONO operation is a function which enables
efficient operation by limiting the maximum power
consumption value.
This function is useful for cases in which attention
should be paid to ensure a circuit breaker will not
trip when the product runs alongside other
appliances.
To start ECONO
operation
1. Press “ECONO button”.
” is displayed on the LCD.
To cancel ECONO
operation
2. Press “ECONO button” again.
” disappears from the LCD.
This diagram is a representation for illustrative purposes only.
* The maximum running current and power consumption of the air conditioner in ECONO
operation vary with the connecting outdoor unit.
NOTE
Notes on ECONO operation
ECONO operation can only be set when the unit is running. Pressing the operation stop
button causes the settings to be canceled, and the “ ” disappears from the LCD.
ECONO operation is a function which enables efficient operation by limiting the power
consumption of the outdoor unit (operating frequency).
ECONO operation functions in AUTO, COOL, DRY, and HEAT operation.
POWERFUL and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
Power consumption may not drop even if ECONO operation is used of the level of power
consumption is already low.
1, 2
Running current and
power consumption
From start up until set
temperature is reached
Time
Maximum during
normal operation
Maximum during
ECONO operation
Normal
operation
ECONO
operation
01_EN_3P278434-1A.fm Page 16 Tuesday, October 4, 2011 5:54 PM
17
TIMER Operation
Timer functions are useful for automatically
switching the air conditioner on or off at night or in
the morning. You can also use OFF TIMER and
ON TIMER in combination.
To use OFF TIMER
operation
Check that the clock is correct.
If not, set the clock to the present time.
(page 8.)
1. Press “OFF TIMER button”.
” is displayed.
” blinks.
2. Press “SELECT button” until
the time setting reaches the
point you like.
Each pressing of either button
increases or decreases the time
setting by 10 minutes. Holding down
either button changes the setting
rapidly.
3. Press “OFF TIMER button”
again.
The TIMER lamp lights yellow.
To cancel the OFF TIMER operation
4. Press “CANCEL button”.
The TIMER lamp goes off.
NOTE
Notes on TIMER operation
When TIMER is set, the present time is not displayed.
Once you set ON/OFF TIMER, the time setting is kept in the memory. (The memory is
canceled when remote controller batteries are replaced.)
When operating the unit via the ON/OFF TIMER, the actual length of operation may vary
from the time entered by the user. (Maximum approx. 10 minutes)
NIGHT SET MODE
When the OFF TIMER is set, the air conditioner automatically adjusts the temperature
setting (0.5°C up in COOL, 2.0°C down in HEAT) to prevent excessive cooling (heating) for
your pleasant sleep.
1, 3
4
2
01_EN_3P278434-1A.fm Page 17 Tuesday, October 4, 2011 5:54 PM
18
TIMER Operation
To use ON TIMER
operation
Check that the clock is correct. If not, set
the clock to the present time. (page 8.)
1. Press “ON TIMER button”.
” is displayed.
“” blinks.
2. Press “SELECT button” until
the time setting reaches the
point you like.
Each pressing of either button
increases or decreases the time setting
by 10 minutes. Holding down either
button changes the setting rapidly.
3. Press “ON TIMER button”
again.
The TIMER lamp lights yellow.
To cancel ON TIMER
operation
4. Press “CANCEL button”.
The TIMER lamp goes off.
To combine ON TIMER and OFF TIMER
A sample setting for combining the two timers is shown below.
ATTENTION
In the following cases, set the timer again.
After a breaker has turned off.
After a power failure.
After replacing batteries in the remote controller.
1, 3
4
2
(Example)
Present time: 11:00 p.m.
(The unit operating)
OFF TIMER at 0:00 a.m.
ON TIMER at 7:00 a.m.
Combined
Display
01_EN_3P278434-1A.fm Page 18 Tuesday, October 4, 2011 5:54 PM
19
WEEKLY TIMER Operation
Up to 4 timer settings can be saved for each day of the week. It is convenient if the WEEKLY TIMER is
set according to the family’s life style.
Using in these cases of WEEKLY TIMER
An example of WEEKLY TIMER settings is shown below.
6:00 8:30 17:30 22:00
25˚C 27˚C
6:00 8:30 17:30 22:00
25˚C 27˚C
8:00 10:00 19:00 21:00
27˚C 27˚C25˚C
Example:
The same timer settings are made for the week from Monday through
Friday while different timer settings are made for the weekend.
Up to 4 reservations per day and 28 reservations per week can be set in the WEEKLY TIMER.
The effective use of the copy mode ensures ease of making reservations.
The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode
and set temperature changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn-
off time of each day can be set. This will turn off the air conditioner automatically if the user
forgets to turn it off.
Make timer settings up to programs 1-4. (see page 20.)
[Monday]
No timer settings
[Saturday]
Make timer settings up to programs 1-4. (see page 20.)
[Sunday]
Use the copy mode to make settings for Tuesday to Friday, because these
settings are the same as those for Monday. (see page 22.)
[Tuesday]
to
[Friday]
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
ON OFF OFF ON
Program 1 Program 2 Program 3 Program 4
OFF
OFF OFF
OFF
27˚C
27˚C
ON
25˚C
25˚C
ON
ON
25˚C
25˚C
ON
27˚C
27˚C
01_EN_3P278434-1A.fm Page 19 Tuesday, October 4, 2011 5:54 PM
20
WEEKLY TIMER Operation
To use WEEKLY TIMER operation
Make sure the day of the week and time are set.
If not, set the day of the week and time. (page 8.)
1. Press “ button”.
The day of the week and the reservation
number of the current day will be displayed
.
1 to 4 settings can be made per day.
2.
Press the “SELECT button” to select the desired
day of the week and reservation number.
Pressing the “SELECT button” changes the
reservation number and the day of the week.
3. Press “NEXT button”.
The day of the week and reservation number will be set.
” and “ ” blink.
4.
Press “SELECT button” to select the desired mode.
Pressing the “SELECT button” changes
” or “ ” setting in sequence.
In case the reservation has already been set, selecting “blank” deletes the reservation.
Go to STEP 9 if “blank” is selected.
5. Press “NEXT button”.
The ON/OFF TIMER mode will be set.
” and the time blink.
6. Press “SELECT button” to select the desired time.
The time can be set between 0:00 and 23:50 in 10 minute intervals.
To return to the ON/OFF TIMER mode setting, press “BACK button”.
Go to STEP 9 when setting the OFF TIMER.
7. Press “NEXT button”.
The time will be set.
” and the temperature blink.
Setting mode
3, 5, 7
1
2, 4, 6
6:00 8:30 17:30 22:00
25˚C 27˚C
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
[Monday]
ON OFF Blank
ON TIMER OFF TIMER blank
Day and number settings
ON/OFF settings Time settings Temperature settings
01_EN_3P278434-1A.fm Page 20 Tuesday, October 4, 2011 5:54 PM
21
8. Press “SELECT button” to
select the desired temperature.
The temperature can be set between
10°C and 32°C.
Cooling: The unit operates at 18°C even
if it is set at 10 to 17°C.
Heating: The unit operates at 30°C even
if it is set at 31 to 32°C.
To return to the time setting, press
“BACK button”.
The set temperature is only displayed
when the mode setting is on.
9. Press “NEXT button”.
The temperature will be set and go to
the next reservation setting.
To continue further settings, repeat the
procedure from STEP 2.
10.Press “ button” to
complete the setting.
Be sure to direct the remote controller
toward the indoor unit and check for a
receiving tone and flashing the
OPERATION lamp.
” is displayed on the LCD and
WEEKLY TIMER operation is activated.
The TIMER lamp lights yellow.
A reservation made once can be easily
copied and the same settings used for another day of the week.
Refer to . (page 22.)
NOTE
Notes on WEEKLY TIMER operation
Do not forget to set the clock on the remote controller first.
The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER
mode) can be set with WEEKLY TIMER. Other settings for ON TIMER are based on the
settings just before the operation.
Both WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The
ON/OFF TIMER operation has priority if it is set while WEEKLY TIMER is still active. The
WEEKLY TIMER will go into standby state, and “ ” will disappear from the LCD.
When ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
Only the time and set temperature set with the weekly timer are sent with the “ button”.
Set the weekly timer only after setting the operation mode, the fan strength, and the fan
direction ahead of time.
Shutting the breaker off, power failure, and other similar events will render operation of the
indoor unit’s internal clock inaccurate. Reset the clock. (page 8.)
The “BACK button” can be used only for the time and temperature settings.
It cannot be used to go back to the reservation number.
9
10
8
01_EN_3P278434-1A.fm Page 21 Tuesday, October 4, 2011 5:54 PM
22
WEEKLY TIMER Operation
A reservation made once can be copied
another day of the week. The whole reservation
of the selected day of the week will be copied
.
1. Press “ button”.
2.
Press “SELECT button” to confirm
the day of the week to be copied
.
3. Press “COPY button” to
activate copy mode.
The whole reservation of the selected
day of the week will be copied.
4.
Press “SELECT button” to select
the destination day of the week
.
5. Press “COPY button”.
The reservation will be copied to the
selected day of the week. The whole reservation of the selected day of the week will be copied.
To continue copying the settings to other days of the week, repeat STEP 4 and STEP 5.
6. Press “ button” to complete the setting.
” is displayed on the LCD and WEEKLY TIMER operation is activated.
NOTE
Copy mode
COPY MODE
The entire reservation of the source day of the week is copied in the copy mode.
In the case of making a reservation change for any day of the week individually after
copying the content of weekly reservations, press “ button” and change the settings
in the steps of . (page 20.)
3, 5
1, 6
2, 4
6:00 8:30 17:30 22:00
25˚C 27˚C
6:00 8:30 17:30 22:00
25˚C 27˚C
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
[Monday]
COPY
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
[Tuesday]
to
[Friday]
Setting Displays
Confirmation display Copy display Paste display Normal display
Setting mode
01_EN_3P278434-1A.fm Page 22 Tuesday, October 4, 2011 5:54 PM
23
Confirming a reservation
The reservation can be confirmed.
1.
Press “ button”.
The day of the week and the reservation number of
the current day will be displayed.
2.
Press “SELECT button” to select the
day of the week and the reservation
number to be confirmed.
Pressing the “SELECT button” displays the
reservation details.
To change the confirmed reserved settings, select the
reservation number and press “NEXT button”.
The mode is switched to setting mode. Go to
STEP 4. (page 20.)
3.
Press “ button” to exit
confirming mode.
•“
is displayed on the LCD and WEEKLY
TIMER operation is activated.
The TIMER lamp lights yellow.
To deactivate WEEKLY
TIMER operation
4.
Press “WEEKLY button” while
” is displayed on the LCD.
The ” will disappear from the LCD.
The TIMER lamp goes off.
To reactivate the WEEKLY TIMER operation, press the “WEEKLY button” again.
If a reservation deactivated with “WEEKLY button” is activated once again, the last reservation mode will be used.
To delete reservations
Refer to . (page 20.)
When selecting desired mode at STEP 4 in setting mode, select “blank”. The reservation will be deleted.
This function can be used for deleting reservations for each day of the week.
5.
Press “ button”.
6.
Select the day of the week to be canceled with the “SELECT button”.
7.
Hold the “WEEKLY button” for 5 seconds.
The reservation of the selected day of the week will be deleted.
8.
Hold “WEEKLY button” for 5 seconds while normal display.
Be sure to direct the remote controller toward the main unit and check for a receiving tone.
This operation is not effective while WEEKLY TIMER is being set.
All reservations will be deleted.
The individual reservation
The reservations for each day of the week
All reservations
1, 3, 5
2, 6
4, 7, 8
Setting mode
Setting Displays
Normal display Confirmation display
Setting mode
01_EN_3P278434-1A.fm Page 23 Tuesday, October 4, 2011 5:54 PM
24
Note for Multi System
This system has one outdoor unit connected to multiple
indoor units.
Selecting the operation mode
1. With the priority room setting present
but inactive or not present.
When more than 1 indoor unit is operating, priority is
given to the first unit that was turned on.
In this case, set the units that are turned on later to
the same operation mode as the first unit.
Otherwise, they will enter the standby state, and the
OPERATION lamp will flash: this does not indicate
malfunction.
NOTE
CAUTION
1. With the priority room setting
active.
See “Priority room setting” on the next page.
NIGHT QUIET mode
(Available only for COOL operation)
NIGHT QUIET mode requires initial programming during installation. Please consult your retailer
or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the night time hours to
prevent annoyance to neighbors.
The NIGHT QUIET mode is activated when the temperature drops 6°C or more below the
highest temperature recorded that day. Therefore, when the temperature difference is less than
4°C, this function will not be activated.
NIGHT QUIET mode reduces slightly the cooling efficiency of the unit.
Notes on operation mode for multi system
COOL, DRY and FAN operation may be used at the same time.
AUTO operation automatically selects COOL operation or HEAT operation based on the
room temperature.
Therefore, AUTO operation is available when selecting the same operation mode as that
of the room with the first unit to be turned on.
Normally, the operation mode in the room where the unit is first run is given priority, but the
following situations are exceptions, so please keep this in mind.
If the operation mode of the first room is FAN operation, then using HEAT operation in any
room after this will give priority to HEAT operation. In this situation, the air conditioner
running in FAN operation will go on standby, and the OPERATION lamp will flash.
01_EN_3P278434-1A.fm Page 24 Tuesday, October 4, 2011 5:54 PM
25
OUTDOOR UNIT QUIET operation
(page 15.)
1. With the priority room setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the multi system, set all indoor
units to OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.
2. With the priority room setting active.
See “Priority room setting”.
COOL/HEAT mode lock
The COOL/HEAT mode lock requires initial programming during installation. Please consult your authorized dealer
for assistance. The COOL/HEAT mode lock sets the unit forcibly to either COOL or HEAT operation. This function
is convenient when you wish to set all indoor units connected to the multi system to the same operation mode.
NOTE
Priority room setting
The priority room setting requires initial programming during installation. Please consult your retailer or dealer for assistance.
The room designated as the priority room takes priority in the following situations;
1. Operation mode priority.
As the operation mode of the priority room takes precedence, the user can select a different
operation mode from other rooms.
* Room A is the priority room in the examples.
Example
When COOL operation is selected in room A while operating the following modes in room B, C and D:
2. Priority when POWERFUL operation is used.
* Room A is the priority room in the examples.
Example
The indoor units in rooms A, B, C and D are all operating. If the unit in room A enters
POWERFUL operation, operation capacity will be concentrated in room A. In such a case, the
cooling (heating) efficiency of the units in rooms B, C and D may be slightly reduced.
3. Priority when using OUTDOOR UNIT QUIET operation.
* Room A is the priority room in the examples.
Example
Just by setting the unit in room A to QUIET operation, the air conditioner starts OUTDOOR UNIT QUIET operation.
You don’t have to set all the operated indoor units to QUIET operation.
The COOL/HEAT mode lock cannot be activated together with the priority room setting.
Operation mode in
room B, C and D
Status of room B, C and D when the unit
in room A is in COOL operation
COOL or DRY or FAN Current operation mode maintained
HEAT
The unit enters standby mode. Operation resumes when
the room A unit stops operating.
AUTO
If the unit is set to COOL operation, it continues. If set to
HEAT operation, it enters standby mode. Operation
resumes when the room A unit stops operating.
01_EN_3P278434-1A.fm Page 25 Tuesday, October 4, 2011 5:54 PM
26
CARE
Care and Cleaning
CAUTION
Indoor unit and remote controller
1. Wipe them with dry soft cloth.
Front panel
1. Open the front panel.
Slide the two stoppers on the left and right
sides inward until they click.
2. Remove the front panel.
Remove the string.
Allowing the front panel to fall forward will
enable you to remove it.
3. Clean the front panel.
Wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
In case of washing the front panel with water,
dry it with cloth, dry it up in the shade after
washing.
4. Attach the front panel.
Insert the front panel into the grooves of the
unit (3 places).
Attach the string to the right, inner-side of the
front grille.
Close the panel slowly.
CAUTION
Units
Do not touch the metal parts of the indoor unit. If you touch those parts, this may cause an
injury.
When removing or attaching the front panel, use a robust and stable stool and watch your
steps carefully.
When removing or attaching the front panel, support the panel securely with hand to prevent
it from falling.
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile
oils, polishing compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front panel is securely fixed.
Before cleaning, be sure to stop the operation and
turn the breaker off.
String
Place front
panel in
grooves.
String
01_EN_3P278434-1A.fm Page 26 Tuesday, October 4, 2011 5:54 PM
27
1. Open the front panel. (page 26.)
2. Remove the air filter.
Press the claws on the right and left of the air
filter down slightly, then pull upward.
3. Take off the titanium apatite
photocatalytic air-purifying filter.
Hold the tabs of the frame, and remove the
claws in 4 places.
4. Clean or replace each filter.
See figure.
5. Set the air filter and titanium apatite
photocatalytic air-purifying filter as
they were and close the front panel.
Operation without air filters may result in
troubles as dust will accumulate inside the
indoor unit.
Air filter
1. Wash the air filters with water or clean them with
vacuum cleaner.
If the dust does not come off easily, wash them with neutral
detergent thinned with lukewarm water, then dry them up in the
shade.
It is recommended to clean the air filters every 2 weeks.
Titanium apatite photocatalytic
air-purifying filter
The titanium apatite photocatalytic air-purifying filter can be renewed by washing it with water once
every 6 months. We recommend replacing it once every 3 years.
[ Maintenance ]
1. Vacuum dusts, and soak in warm water or water for about 10 to 15
minutes if dirt is heavy.
Do not remove filter from frame when washing with water.
2. After washing, shake off remaining water and dry in the shade.
Since the material is made out of paper, do not wring out the filter when removing water
from it.
[ Replacement ]
1. Remove the tabs on the filter frame and replace with a new filter.
Dispose of the old filter as flammable waste.
Filters
Air filter
Titanium apatite
photocatalytic
air-purifying filter
01_EN_3P278434-1A.fm Page 27 Tuesday, October 4, 2011 5:54 PM
28
NOTE
Check
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
Press “MODE button” and select “FAN” operation.
Press “ON/OFF button” and start the operation.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
NOTE
Operation with dirty filters:
(1) cannot deodorize the air. (2) cannot clean the air.
(3) results in poor heating or cooling.(4) may cause odour.
To order titanium apatite photocatalytic air-purifying filter contact to the service shop there
you bought the air conditioner.
Dispose of old filters as flammable waste.
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and
consult the service shop if this is the case.
When a multi outdoor unit is connected, make sure the heating operation is not used at
the other room before you use the fan operation. (page 24.)
Item Part No.
Titanium apatite photocatalytic air-purifying filter
(without frame) 1 set
KAF968A42
01_EN_3P278434-1A.fm Page 28 Tuesday, October 4, 2011 5:54 PM
29
TROUBLESHOOTING
Troubleshooting
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
These cases are not troubles.
Case Explanation
Operation does not start soon.
When ON/OFF button was pressed
soon after operation was stopped.
When the mode was reselected.
This is to protect the air conditioner.
You should wait for about 3 minutes.
Hot air does not flow out soon
after the start of HEAT
operation.
The air conditioner is warming up. You should wait for 1 to 4 minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)
The HEAT operation stops suddenly
and a flowing sound is heard.
The outdoor unit is taking away the frost.
The HEAT operation starts after the frost on the outdoor unit is removed.
You should wait for about 4 to 12 minutes.
A sound is heard. A sound like a flow of water
This sound is generated because the refrigerant in the air conditioner is flowing.
This is a pumping sound of the water in the air conditioner
and heard when the water is pumped out from the air
conditioner in cooling or drying operation.
The refrigerant flows in the air conditioner even if the air conditioner
is not working when the indoor units in other rooms are in operation.
Blowing sound
This sound is generated when the flow of the refrigerant in
the air conditioner is switched over.
Ticking sound
This sound is generated when the size of the air conditioner
slightly expands or shrinks as a result of temperature changes.
Clicking sound during operation or idle time
This sound is generated when the refrigerant control
valves or the electrical parts operate.
Clopping sound
This sound is heard from the inside of the air conditioner
when the exhaust fan is activated while the room doors are
closed. Open the window or turn off the exhaust fan.
The outdoor unit emits water or
steam.
In HEAT operation
The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
In COOL or DRY operation
Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.
Mist comes out of the indoor
unit.
This happens when the air in the room is cooled into mist by
the cold airflow during cooling operation.
This is because the air in the room is cooled by the heat
exchanger and becomes mist during defrost operation.
The indoor unit gives out odour.
This happens when smells of the room, furniture, or cigarettes
are absorbed into the unit and discharged with the airflow.
(If this happens, we recommend you to have the indoor unit washed by a
technician. Consult the service shop where you bought the air conditioner.)
01_EN_3P278434-1A.fm Page 29 Tuesday, October 4, 2011 5:54 PM
30
Please check again before calling a repair person.
Case Explanation
The outdoor fan rotates while
the air conditioner is not in
operation.
After operation is stopped:
The outdoor fan continues rotating for another 60 seconds
for system protection.
While the air conditioner is not in operation:
When the outdoor temperature is very high, the outdoor
fan starts rotating for system protection.
The operation stopped
suddenly.
(OPERATION lamp is on.)
For system protection, the air conditioner may stop operating
on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.
No remote controller signals are
displayed.
The remote controller sensitivity is low.
The display is low in contrast or
blacked out.
The display runs out of control.
The batteries are dying and the remote controller is malfunc-
tioning. Replace all the batteries with new size AAA alkaline
batteries. For details, refer to set the batteries of this manual.
(page 7.)
* If the reset button is provided, press the reset button after the
batteries are replaced.
The ON/OFF TIMER does not
operate according to the settings.
Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.
Change or disable the settings in the WEEKLY TIMER. (page 20.)
Check again.
Case Check
The air conditioner does not
operate.
(OPERATION lamp is off.)
Hasn’t a breaker turned off or a fuse blown?
Isn’t it a power failure?
Are batteries set in the remote controller?
Is the timer setting correct?
Cooling (Heating) effect is poor. Are the air filters clean?
Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Is the temperature setting appropriate?
Are the windows and doors closed?
Are the airflow rate and the air direction set appropriately?
Operation stops suddenly.
(OPERATION lamp flashes.)
Are the air filters clean?
Clean the air filters.
Is there anything to block the air inlet or the outlet of the
indoor and the outdoor units?
Turn the bleaker off and take all obstacles away. Then turn it on again and
try operating the air conditioner with the remote controller. If the lamp still
flashes, call the service shop where you bought the air conditioner.
Are operation modes all the same for indoor units connected
to outdoor units in the multi system?
If not, set all indoor units to the same operation mode and
confirm that the lamps flash.
Moreover, when the operation mode is in AUTO, set all
indoor unit operation modes to COOL or HEAT for a moment
and check again that the lamps are normal.
If the lamps stop flashing after the above steps, there is no malfunction. (page 24.)
An abnormal functioning
happens during operation.
The air conditioner may malfunction with lightning or radio waves. Turn the breaker
off, turn it on again and try operating the air conditioner with the remote controller.
01_EN_3P278434-1A.fm Page 30 Tuesday, October 4, 2011 5:54 PM
31
WARNING
When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker off.
Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
Consult the service shop where you bought the air conditioner.
Do not attempt to repair or modify the air conditioner by yourself.
Incorrect work may result in electric shocks or fire.
Consult the service shop where you bought the air conditioner.
If one of the following symptoms takes place, call the service shop immediately.
Dismantling of the unit, treatment of the refrigerant, oil and eventual other parts, should be done in
accordance with the relevant local and national regulations.
In certain operating conditions, the inside of the air conditioner may get foul after several seasons of
use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist
aside from regular cleaning by the user. For specialist maintenance, contact the service shop where
you bought the air conditioner.
The maintenance cost must be born by the user.
Call the service shop immediately.
After a power failure
The air conditioner automatically resumes
operation in about 3 minutes. You should just
wait for a while.
Lightning
If lightning may strike the neighbouring area,
stop operation and turn the breaker off for
system protection.
Disposal requirements.
We recommend periodical maintenance.
The power cord is abnormally hot or damaged.
An abnormal sound is heard during operation.
The safety breaker, a fuse, or the earth leakage breaker
cuts off the operation frequently.
A switch or a button often fails to work properly.
There is a burning smell.
Water leaks from the indoor unit.
Turn the breaker
off and call the
service shop.
01_EN_3P278434-1A.fm Page 31 Tuesday, October 4, 2011 5:54 PM
32
FAULT DIAGNOSIS BY REMOTE CONTROLLER
In the ARC452A series, the temperature display sections on the main unit indicate corresponding codes.
1. When the TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on
the temperature display section.
2. Press the TIMER CANCEL button repeatedly until a continuous beep is produced.
The code indication changes as shown below, and notifies with a long beep.
NOTE
Fault diagnosis.
CODE MEANING
SYSTEM
00 NORMAL
UA INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR UNIT
A1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6 FAN MOTOR FAULT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR
UNIT
EA COOLING-HEATING SWITCHING ERROR
E1 CIRCUIT BOARD FAULT
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
E8 OVERCURRENT INPUT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 HIGH PRESSURE CONTROL (IN COOLING)
H0 SENSOR FAULT
H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3 ELECTRICAL PARTS HEAT FAULT
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the TIMER CANCEL button down for 5 seconds. The code
display also cancel itself if the button is not pressed for 1 minute.
TIMER CANCEL button
It cancels the timer setting.
01_EN_3P278434-1A.fm Page 32 Tuesday, October 4, 2011 5:54 PM
(1111)
HT
3P278434-1A
M10B241A
Two-dimensional bar code is a code
for manufacturing.
00_CV_3P278434-1A.fm Page 2 Friday, July 22, 2011 4:19 PM
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Daikin FVXS35LV1A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Daikin FVXS35LV1A in de taal/talen: Engels als bijlage per email.

De handleiding is 2,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info