Foreword
Dear Customer,
We would like to thank you for buying this DRU prod-
uct. Our products have been designed and produced to
meet the highest possible quality, performance and safety
requirements, allowing you to enjoy years of problem-free
use.
In this booklet you will find instructions for the installation
and use of your new appliance. Please read these instruc-
tions and the manual carefully to familiarize yourself with
the appliance. If you require any further support, please do
not hesitate to contact your supplier.
Unpacking
Once the heater has been unpacked, all packaging should
be disposed of in the regular manner.
Connection
This appliance should be connected by a registered install-
er.
INSTRUCTIONS FOR INSTALLATION
Type of gas
This appliance can only be used and is only suitable for the
country and the type of gas mentioned on the type iden-
tification tag. Please check that the local gas and pressure
correspond with the specifications on the type identifica-
tion tag. All regulations regarding gas installation, includ-
ing any local regulations, must be observed at all times.
Installation and maintenance of the appliance should be
performed by a professional certified expert with proven
knowledge and demonstrable competence in this field.
A professional expert takes all technical aspects such as
heat output and gas connection into account, as well as
the flue gas discharge requirements. The installation
manual will give you the information you need to install
the appliance in such a way that it will operate properly
and safely. If the installation instruction is not clear,
national/local regulations must be observed.
To operate the heater on propane, it should be converted
by a competend person. A conversion set can be ordered
through your supplier.
Important
• Keep curtains and any other flammable materials at least
50cm away form the appliance.
• Caution! Touching the heater when hot can cause burns
and blisters!
• The appliance should be installed and maintained by a
registered installer.
• Do not install any so-called dust filter on or under the
casing.
• Do not hang wet clothes and towels etc. on the heater to
dry.
• The appliance was designed for atmospheric and heating
purposes. This means that all visible surfaces, including the
glass pane, can become hotter than 100C°. It is recom-
mended to always place a protective grating in front of
the appliance when there are children, elderly people or
handicapped persons in the same room as the appliance.
If it is possible that vulnerable people are regularly present
in the room with no supervision, a fixed guard should be
mounted around the appliance.
General
The appliance can be mounted either on a wall of incom-
bustible material (e.g. stone or concrete) or on a wall of
combustible material (e.g. wood). Style 3-01, 4-01 and 5-01
on propane (G31) can be placed in vehicles pulling mobile
units, provided the following is observed:
When the appliance is working, the mobile unit must be
standing still;
When the vehicle pulling the mobile unit is being filled
with fuel, the appliance must be switched off;
If glass is broken, switch off the appliance and contact an
installer;
In case of a gas leak, switch off the appliance as well as the
gas supply tap and contact an installer;
Flue gas discharge must remain unobstructed at all times.
Installation to a wall of non-flammable material
(fig. 6, 8, pg. 58, 59)
The models are suitable for hanging installation only. Allow
at least 1 metre’s clearance above the heater to enable
sufficient heat circulation. When installed hanging, at least
1 m free space should be kept above the appliance to
allow sufficient heat dissipation. When intalled standing,
the bottom of the mounting sheet (2) should stand on the
floor, this is the minimum height between the floor and
centre of wall duct (size F. fig 6, 8, pg. 58, 59).
The mounting plate (2) serves as a template to mark the
position of the duct. To be able to hang the casing over
the interior, a minimal clearance of 25 mm must be allo-
wed between the appliance and a windowsill or suchlike.
The minimum clear installation height (Y) required for
each of the various models is listed in the table on page
60.
The standard wall duct
Drill a horizontal hole in the wall, ø E to take the air-sup-
ply pipe. The wall duct should slope at an angle of approx.
2º.
The standard wall duct is suitable for walls with a thick-
ness of 50 – 330 mm and the standard extended wall duct
for walls with a thickness of 50 – 600 mm. Depending on
the thickness of the wall, the inlet and outlet pipes should
be made to length, i.e.:
10
INSTRUCTIONS FOR INSTALLATION
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw DRU STYLE 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van DRU STYLE 3 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Noors als bijlage per email.

De handleiding is 1,26 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van DRU STYLE 3

DRU STYLE 3 Gebruiksaanwijzing en installatiehandleiding - Nederlands - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info